Product Overview
  • Burst Pressure 29 psi Maximum
  • Compensated Temperature, Max 60 °C
  • Compensated Temperature, Min -40 °C
  • Electrical Connection Removable Screw Terminal
  • Electrical Output 0 to 5 V
  • Media Compatibility Clean dry air / inert gas, Fuel gases, HVAC / room air, Inert / non-reactive gases, Hydrogen, Nitrogen, Non-corrosive Dry Gasses, Oxygen
  • Mounting Mounting plate
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -40 °C
  • Output Resistance <10 Ω
  • Output Signal Voltage
  • Process Connection Size 1/8 in
  • Process Connection Type Barbed Fitting
  • Proof Pressure Up to 1500 hpa
  • Resolution 0.1 hPa
  • Response Time <100 ms
  • Sensitivity Effect <± 0.09% full scale/50°C
  • Series ID PX2780
  • Span Setting Adjustable Range ± 5 mV
  • Stability <± 0.1
  • Stability Note Long Term Stability: <± 0.1 hPa (mb)/year
  • Storage Temperature, Max 120 °C
  • Storage Temperature, Min -60 °C
  • Supply Power Note 9.5 to 28 Vdc (3 mA operate mode, 1 µA sleep mode) 3- or 4-wire circuit
  • Supply Voltage 9.5 to 28 Vdc
  • Thermal Effect on Span error, Max ± 1% gage
  • Warm-Up Shift <0.1 hPa (mb) maximum
  • Warm Up Time <1 sec
  • Weight 137 g
  • Zero/Balance Error <± 0.18% full scale/50°C
  • Zero Setting Adjustable Range ± 5 mV

Supported Applications

The Omega PX2780 Series consists of high accuracy barometric pressure transducers designed for applications in industry and science where accuracy, fast dynamic response, and long-term stability are important. These units sense absolute pressure and convert it to a proportional high-level analog output. The series is intended for use with non-condensing air or gas.

Operating Conditions & Performance

The PX2780 operates within an ambient temperature range of -40 to 60°C (-40 to 140°F) and a process temperature range of -40 to 60°C (-40 to 140°F). Storage temperatures are rated from -60 to 120°C (-76 to 248°F). The unit features a response time of <100 ms. Accuracy varies by barometric range and temperature, expressed as RSS (Root Sum Square) of end point non-linearity, hysteresis, non-repeatability, and calibration uncertainty:

  • 500 to 1100 hPa (mb) Range: ±0.6 hPa at 20°C; ±2.5 hPa across -40 to 60°C.
  • 600 to 1100 hPa (mb) or 600 to 1060 hPa (mb) Range: ±0.5 hPa at 20°C; ±2.0 hPa across -40 to 60°C.
  • 800 to 1100 hPa (mb) or 800 to 1060 hPa (mb) Range: ±0.3 hPa at 20°C; ±1.5 hPa across -40 to 60°C.

The sensor resolution is 0.1 hPa (mb). The pressure rating is 1500 hPa (mb) with a burst pressure of 2000 hPa (mb).

Electrical Specifications

  • Excitation Voltage: 9.5 to 28 Vdc.
  • Output Signal: 0 to 5 Vdc (available with 3- or 4-wire circuit).
  • Power Consumption: 3 mA in operate mode; 1 µA in sleep mode.

Configuration Options

The series is packaged in a rugged stainless steel and polyester case. A removable 5-pin terminal strip (BL 3.5 screw clamp) facilitates connections, with four-wire connection recommended to avoid voltage drop in the negative power line.

  • Process Connection: ¼" barbed fitting (0.290 in diameter).
  • Housing Dimensions: Depth: 90.3 mm (3.56 in); Height: 76.7 mm (3.02 in); Width: 59.9 mm (2.36 in). Mounting hole diameter is 0.140 in.
  • Weight: 137 g (4.8 oz).

The unit includes a sleep mode that draws only 1 micro amp, allowing almost instant turn-on and reading for remote applications. It is shipped in sleep mode and requires an external trigger to activate; terminal 1 can be jumpered to terminal 4 for continuous operation.

Key Product Differences

The PX2780 series offers five specific model configurations distinguished by barometric range:

  • PX2780-500B5V: 500 to 1100 hPa (mb).
  • PX2780-600B5V: 600 to 1100 hPa (mb).
  • PX2780-600NB5V: 600 to 1060 hPa (mb).
  • PX2780-800B5V: 800 to 1100 hPa (mb).
  • PX2780-800NB5V: 800 to 1060 hPa (mb).

All models feature a high accuracy ceramic sensor coupled with a digital compensation circuit using a custom ASIC. Each unit comes complete with an NIST traceable calibration certificate and operator's manual.

Accessories

Pressure Snubbers to Protect Against Pressure Surges
From C$27.12
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration