  • Splits one analog signal into two outputs: The ACI ARM2 accepts a single voltage or current input and provides two matching DC current sourcing outputs that track together.
  • Ideal for signal loop monitoring: Use it when one sensor or controller signal needs to be shared with two devices, controllers, or monitoring points.
  • Flexible signal rescaling: Supports voltage-to-current, current-to-current, and resistance-to-current conversion for adapting non-compatible control signals.
  • Adjustable field calibration: Multi-turn potentiometers allow fine adjustment of gain, offset, attenuation, and reverse-acting output for precise setup.
  • Improves control system compatibility: Helps shrink or expand sensor ranges, increase analog input resolution, and match signal ranges to BAS requirements.
  • Reverse signal capability: Can reverse the output signal, making it useful when equipment requires opposite-acting control logic.
  • Built-in sensor power: Includes a regulated 23 VDC power output to support compatible sensors in signal conversion applications.
  • Panel-ready design: Compact snap-track mounted module with 45° captive screw terminals supports clean installation in control panels and equipment enclosures.
Series-ARM2
From
Analog Current/Voltage Rescaling Signal Splitter Series-ARM2 Series-ARM2
loading all models
Product Overview
  • Accuracy Detail Signal Output Accuracy: Less than or equal to 1% of output span over full temperature range when using 1:1 input to output
  • Applications Building and Maintenance, Electronic Equipment, Environmental Monitoring
  • Approvals RoHS2, WEEE
  • Electrical Connection Screw Terminal
  • Height 1 in
  • Impedance Output Note Output Current Load Impedance: 750Ω @ 20 mA
  • Input Current 0 to 44 mA
  • Input Type Note Input Resistance Signal Range: 0 to 500,000Ω
  • Input Voltage Note 0-35 VDC @ 1,000,000Ω
  • Length 3.69 in
  • Materials PVC
  • Operating Humidity 10 to 95% RH, non-condensing
  • Operating Temperature, Max 120 °F
  • Operating Temperature, Min 35 °F
  • Output Configurations Rescalable
  • Output Note Field Adjustable Ranges: Multi-turn potentiometers; Output Current Signal Range: Signal Gain 1 to 20 times (nominal) depending on input value;Output Signal Attenuation: 0 to 100%; Output Signal Offset: 0.25 to 20 VDC; Output Signal Inversion (RA): 20 to 0 mA (nominal)
  • Series ID Series-ARM2
  • Storage Temperature, Max 150 °F
  • Storage Temperature, Min -20 °F
  • Supply Current 100 mA
  • Supply Voltage 24 Vac/Vdc
  • Tightening Torque 0.5 Nm (Minimum); 0.6 Nm (Maximum)
  • Weight 0.231 lb
  • Width 2.17 in
  • Wire Gauge 22 to 12 AWG

Supported Applications

The ACI Series ARM2 is an Analog Current/Voltage Rescaling Signal Splitter designed to accept a single analog voltage or current signal and split it into two DC non-isolated current sourcing outputs. The device functions as a primary signal splitter where the two outputs are always scaled identically and track each other. Documented applications include:

  • Signal loop monitoring
  • Resistance to current conversion
  • Voltage to current conversion
  • Current to current conversion
  • Shrinking or expanding sensor ranges
  • Increasing analog input resolution
  • Reversing a signal
  • Adapting non-compatible signals

The unit accepts resistance inputs via voltage divider applications and features top-adjust trimmer potentiometers for fine adjustments to output ranges.

Operating Conditions & Performance

The Series ARM2 operates within an ambient temperature range of 35 to 120°F (1.7 to 48.9°C) with a storage temperature capability from -20 to 150°F (-28.9 to 65.5°C). It is rated for humidity levels between 10 and 95% non-condensing.

Input signal ranges are defined as:

  • Voltage: 0-35 VDC @ 1,000,000Ω
  • Current: 0 to 44 mA @ 250Ω
  • Resistance: 0 to 500,000Ω

The device provides a signal output accuracy of less than or equal to 1% of output span over the full temperature range when using 1:1 input to output; otherwise, accuracy is calibration dependent. The maximum supply current draw is 100 mA.

Power and Output Specifications

The unit requires a power supply of 22.8 to 30 VDC or 21.6 to 26.4 VAC. It includes a regulated power output of 23 VDC nominal @ 24 VAC Power Supply, with a maximum current capacity of 30 mA for powering sensors.

Output signal capabilities include:

  • Signal Gain: 1 to 20 times (nominal) depending on input value
  • Attenuation: 0 to 100%
  • Offset: 0.25 to 20 VDC
  • Inversion: 20 to 0 mA (nominal)
  • Load Impedance: 750Ω @ 20 mA

Configuration Options

The Series ARM2 is configured with a Polyvinyl Chloride (PVC) snap track housing that meets UL94 V-0 flammability rating. Electrical connections are made via 45° captive screw terminal blocks, supporting wire sizes from 12 AWG (3.31 mm²) to 22 AWG (0.33 mm²). The recommended torque for the terminal block is a minimum of 0.5 Nm and a maximum of 0.6 Nm.

Field calibration is supported via multi-turn potentiometers, with factory calibration available upon request as a special order option. The series supports several accessory configurations:

  • DIN Rail Adapter Kit: Model A/DRC 3.88 X 2.18 (Item # 142623)
  • Transient Voltage Suppressor: Bi-directional, 56VAC/DC, 1500W (Model A/DO008, Item # 142583)
  • Metal Enclosure: 20 Gauge Metal Enclosure designed to hold interfaces products (Model ENC1, Item # 102472)

Product dimensions for the board only are 3.69" (W) x 2.17" (H). With the snap track included, overall dimensions are 3.88" (W) x 2.18" (H) with a depth of 0.70".

Key Product Differences

The standard model is designated as ARM2 (Item # 102029). A special calibration ordering option, C/ARM2 (Item # 137062), allows for specific input and output configurations. The device does not isolate the input signals from the output signals; users requiring isolation must utilize separate Analog Isolation Modules such as AIM1 or AIM2.

When powered with 24 VDC, it is recommended to use an isolated UL-listed class 2 transformer. If power is shared with devices containing coils (relays, solenoids), each coil requires a Transient Voltage Suppressor (ACI Part: 142583) or diode placed across the coil.

The Series ARM2 carries RoHS2 and WEEE approvals and is covered by ACI's Two (2) Year Limited Warranty.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 24ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration