Series-AVUL
Air Velocity Transmitters, 3% or 5% Accuracy, Ideal for VAV Systems
Models In Stock
- Sensing elements have been coated with an engineered conformal coating to ensure durability and longevity
- Field selectable ranges can be quickly configured without power to the unit
Series-AVUL
From
C$
315.28
Models In Stock
Product Overview
- Air Velocity, Max 4000 FPM
- Air Velocity Note 1000, 2000, 3000, 4000 FPM (5, 10, 15, 20 m/s); Field selectable
- Device Load 1/8 Unit
- Enclosure Ratings IP66, NEMA Type 4X
- Load Resistance Current Output: 0 to 1100 Ω max; Voltage Output: 1 kΩ min
- Materials, Wetted Consult Factory
- Media Compatibility Clean dry air / inert gas, Inert / non-reactive gases, Clean Dry Air, Helium, Nitrogen, Non-Corrosive Dry Gases
- Mounting Orientation Sensor Tip Parallel to Flow
- Operating Temperature, Max 122 °F
- Operating Temperature, Min 32 °F
- Output Detail 4 to 20 mA; 0 to 5 Vdc, 0 to 10 Vdc
- Output Signal Current, Voltage
- Power Consumption 60 mA + Output Current
- Relative Humidity 5 to 95% RH Non-Condensing
- Response Time 10 s @ 90%
- Series ID Series-AVUL
- Supply Power Type AC/DC
- Supply Voltage 19 to 30 Vdc/Vac
- Weight 6 oz
- Wire Gauge 26 to 16 AWG
- Zero Setting Adjustable Range Digital Push Buttons
Supported Applications
The Dwyer Series AVUL Air Velocity Transmitters measure air velocity or volumetric flow in imperial or metric units. The series is designed for use with clean air and non-combustible, compatible gases. Models provide simultaneous current and voltage outputs to serve as universal inputs to monitoring equipment.
Operating Conditions & Performance
The Series AVUL operates within a process temperature range of 32 to 122°F (0 to 50°C) with an ambient humidity rating of 5 to 95% RH, non-condensing. Accuracy is specified as ±(0.2 m/s + 5% of reading) or ±(0.2 m/s + 3% of reading) @ standard conditions, depending on the model selected.
- Measurement ranges are field selectable: 1000, 2000, 3000, 4000 FPM (5, 10, 15, 20 m/s).
- The typical response time is 10 s (90%).
- Power requirements are 24 VDC ±20% or 24 VAC ±20%.
- Load resistance limits: Current output 0 to 1100 Ω max; Voltage output minimum load resistance 1 kΩ.
Configuration Options
The series supports multiple configuration options for mounting, signal outputs, and communication protocols. The enclosure rating is NEMA 4X (IP66), with electrical connections via a 4-wire removable European style terminal block for 16 to 26 AWG wire.
- Accuracy: Models available in 3% or 5% of reading accuracy classes.
- Mounting: Duct mount configuration (code "D").
- Analog Outputs: Universal analog output code A1 provides simultaneous 0-5 VDC, 0-10 VDC, and 4-20 mA signals. Output range, units, and voltage selection are configurable via local DIP switches.
- Communication Protocols (Optional): BACnet MS/TP (code "B1") or Modbus® RTU/ASCII (code "M1"). These options allow daisy-chained communication providing access to velocity, flow data, and air temperature information. Supported baud rates include 9600 through 115200.
- Display Options: Integral LCD display or the Model A-435-A remote display tool for local monitoring and configuration.
Key Product Differences
The Series AVUL model number structure follows the format AVUL - <Accuracy> - <Mounting> - <Output> - <Options>. For example, a 3% accuracy duct mount with universal analog output and LCD is designated as AVUL-3DA1-LCD.
- Accuracy codes: "5" for ±(0.2 m/s + 5% of reading) or "3" for ±(0.2 m/s + 3% of reading).
- Output codes: A1 (Analog universal), B1 (Analog + BACnet MS/TP), M1 (Analog + Modbus® RTU/ASCII).
- Option suffixes include LCD for integral display, FC for Factory calibration certificate, NIST for NIST certificate, GLD for Electrical cable gland, and SF for Silicone free.