SAP-TC-Series

Adhesive Pad Thermocouple Sensor

Models In Stock
  • Made of silicone rubber for excellent flexibility
  • Self-adhesive thin backing to increase response time
  • Attach directly to clean surface for accurate temperature measurement
  • Made for one-time placement on surface via self-adhesive pad
SAP-TC-Series
From C$ 75.53
Models In Stock
Adhesive Pad Thermocouple Sensor SAP-TC-Series SAP-TC-Series
loading all models
Product Overview
  • Electrical Connection Stripped Leads
  • Insulation PFA
  • Pad Material Silicone
  • Process Temperature, Max 200 °C
  • Process Temperature, Min -50 °C
  • Series ID SAP-TC-Series
  • Wire Gauge 24 AWG

Supported Applications

The Omega SAP-TC-Series consists of adhesive pad thermocouple sensors designed for surface temperature measurements. The integral sensor is bonded onto the inner surface of exposed silicone material to facilitate faster response on contact surfaces. Documented applications include hot plate measurements, pipe measurements, and direct connection to instrument casings or motor housings.

Operating Conditions & Performance

The series operates within a temperature range of -50 to 200°C (-58 to 392°F). The sensor construction utilizes a silicone pad with PFA-coated lead wire, specified as 24 AWG. Mounting is achieved via an adhesive surface mount style suitable for both flat and curved surfaces.

Configuration Options

The SAP-TC-Series offers configuration options across thermocouple types, pad geometry, wire lengths, and termination styles to accommodate specific installation needs.

  • Thermocouple Types: Type K, J, T, and E are available.
  • Pad Designations: SAPC models feature a pad design for curved surfaces; SAPF models utilize a pad design for flat surfaces.
  • Dimensions: SAPC pads measure 0.59 X 1.97 X 0.29 in (15 x 50 x 7.4 mm). SAPF pads measure 1.41 x 0.48 x 0.29 in (35 x 12 x 7.4 mm).
  • Wire Lengths: Standard lengths include 36, 72, and 120 inches; other lengths are available.
  • Termination: Stripped ends are standard, with other connection options available upon request.

Key Product Differences

Variants within the series differ primarily by pad geometry and thermocouple type. The model number guide follows the format SAPC-Type-Length or SAPF-Type-Length. For example, a part such as SAPC-K-72 denotes a self-adhesive silicone sensor with a pad for curved surfaces (SAPC), Type K thermocouple element, and 72 inches of PFA-coated lead wire with stripped leads. Variants ending in "I" followed by metric lengths (e.g., -1M or -2M) indicate specific meter-based configurations available within the series.

Rated 5 out of 5 by from Better than I expected Works very well, fast and accurate measurement time and physically more rugged than I expected. Adhesive is good enough for temporary work which is what I needed.
Date published: 2023-12-11
Rated 5 out of 5 by from Shipped quickly .easy to purchase and came correct Shipped quickly . easy to purchase and came correct.
Date published: 2022-02-15
  • y_2026, m_8, d_7, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_SAPC-E-120, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Hi, Can you Please advise Type K Adhesive Pad Thermocouple is calibrated in Factory. and Calibration Certificate provide or not ?

Asked by: Yagne
Hi, Calibration certificate is not included.
Answered by: JA App Engineering
Date published: 2026-07-18

Can this be ordered with a NIST traceable calibration certificate?

Asked by: barrett
Thank you for your inquiry. Yes it can be ordered with a NIST calibration certificate. Please send your quote request to sales@omega.com
Answered by: Application Engineer MC
Date published: 2023-02-14

Is this a resistive sensor? if yes, what is the resistance variation ?

Asked by: gustavo 53
Thank you for your inquiry gustavo53. Thermocouples are not resistive sensors. They don't output resistance but millivolts.
Answered by: Application Engineer MC
Date published: 2023-02-08

What is the adhesive material? Do you have more information on the Silicone blend used for the coating?

Asked by: lightpunster
This information is not readily available and if required send a request for information to temp@dwyeromega.com for further research.
Answered by: ApplicationEngineerANB
Date published: 2024-06-19

The TC connector sold on Omega SMPW-TI-M has a service rating of -29C. Will this connector work with SAPF-TI-2M TC? SAPF-TI-2M is rated to -50, what is a compatible connector?

Asked by: QTS TestEng
The SMPW-TI-M will work as a connector for the probe to carry a signal through the full Type T temperature range. It cannot physically be used below the -29C rating due to the materials it is constructed with. The connecters are most often used in an ambient temperature where the instrument accepting the reading is located.
Answered by: ApplicationEngineerANB
Date published: 2023-12-19
  • y_2026, m_8, d_8, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_CA, sid_SAPC-E-120, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 8ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration