Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-VF

Acrylic Flowmeters for Gas/Liquid, 2" & 4" Scales, NIST Options

Models In Stock
  • Fits lab benches, analyzer panels, and purge lines for gas sampling, cooling water, and instrument air
  • Body precision machined from solid acrylic with a tapered bore; 2" and 4" scale lengths for air or water
  • Compact acrylic variable area flowmeter (rotameter) for low-flow air, gas, and liquid monitoring.
  • Full visual inspection of the float on a white background, with direct reading scales that skip conversions
Series-VF
From C$ 84.36
Models In Stock
Acrylic Flowmeters for Gas/Liquid, 2" & 4" Scales, NIST Options Series-VF Series-VF
loading all models
Product Overview
  • Applications Chemicals, Environmental Monitoring, Medical
  • Compliance Note Meets the technical requirements of EU Directive 2011/65/EU (RoHS II)
  • Mounting Orientation Vertical
  • Measurement Pressure Type Gauge
  • Process Connection Size 1/8 in
  • Process Connection Type NPT Female
  • Proof Pressure Up to 100 psi
  • Series ID Series-VF

Supported Applications

The Dwyer Series VF Visi-Float® Acrylic Flowmeters are direct reading, precision machined instruments designed for gas and liquid flow measurement. The series provides clear acrylic bodies suitable for applications requiring visual monitoring of fluid or air movement.

  • Gases: Air and compatible gases
  • Liquids: Water and compatible liquids

Operating Conditions & Performance

The Series VF offers two primary scale lengths with distinct accuracy ratings. The VFA model features a 2" typical length scale, while the VFB model provides a 4" typical length scale.
  • Accuracy: VFA models are rated at 5% FS; VFB models are rated at 3% FS.
  • Pressure and Temperature Limits (Without Valve): 100 psig (6.9 bar) @ 150°F (65°C); 150 psig (10 bar) @ 100°F (38°C).
  • Pressure and Temperature Limits (With Valve): 100 psig (6.9 bar) @ 120°F (48°C).

The precision machined tapered bore enables high repeatability. Installation requires a vertical mounting position, and the mounting panel should be free of excessive vibration to ensure proper operation.

Configuration Options

The series supports extensive configuration options for ranges, valves, materials, and connections.

  • Ranges: Available in numerous scales including SCFH air (e.g., 0.1 to 1 up to 20 to 200), LPM air, CC/min water, GPH water, and GPM water.
  • Valves: Configurable with no valve (standard), brass valve (-BV), or stainless steel valve (-SSV).
  • Wetted Materials:
    • Body: Acrylic plastic
    • O-ring: Buna-N standard; fluoroelastomer available via -VT option
    • Metal parts: Brass standard, SS optional via -SS option
    • Float materials vary by range and include stainless steel (SS), black glass, aluminum, or K monel.
  • Process Connections: Standard 1/8" female NPT. VFB ranges 85 and 86 feature 1/4" NPT back connections or 3/8" NPT end connections; these specific ranges are not available with brass valves.
  • Options:
    • -ARB: Arbitrary scale
    • -AT: Aluminum tag
    • -EC: End connections
    • -NIST: NIST traceable calibration certificate
    • -PF: Adjustable pointer flag
    • -PTFE: PTFE valve seat
    • -SPL: Special cleaning
    • -WL: Without logo

Key Product Differences

The series is divided into two model families based on scale length and accuracy:

  • VFA: 2" typical length, 5% FS accuracy.
  • VFB: 4" typical length, 3% FS accuracy.

Differences in dimensions correspond to the model family. For example, overall dimension A is 4 [101.6] for Model VFA and 6-1/2 [165.1] for Model VFB. Dimension B (connection height) varies from 3 [76.20] on VFA models to 5-1/2 [139.7] on VFB models.

Special service configurations include non-removable valves available on special order for high pressure or toxic gas/fluid applications. Regulator kits (RKA, RK-RMB) are offered as accessories to maintain constant differential pressure in systems with fluctuating inlet or discharge pressure.

Accessories

accessories

Regulator kit for VFB.
C$440.15 / each
0 In Stock
Regulator kit for RMA or VFA.
C$440.15 / each
6 In Stock
Rated 5 out of 5 by from Great Great Product and customer support. Will definitely buy again.
Date published: 2026-07-27
Rated 5 out of 5 by from VFA-43-BV Very easy to order. Got the product in a reasonable time
Date published: 2026-07-17
Rated 5 out of 5 by from Best price, quality and timely delivery. Best price, quality and timely delivery. Received items as per promised date
Date published: 2026-07-16
Rated 5 out of 5 by from Flowmeters that provide peace of mind They are very robust, reliable, at an excellent cost
Date published: 2026-07-09
Rated 4 out of 5 by from Inside sales and customer service tech product Order was received and processed timely. Product is high quality.
Date published: 2026-06-29
Rated 5 out of 5 by from Quality Meter This is exactly what I needed for my project. A small compact meter.
Date published: 2026-06-15
Rated 5 out of 5 by from Easy & Fast The flowmeter was easy to order and was delivered to our customer quickly
Date published: 2026-06-09
Rated 5 out of 5 by from Dwyer VF products review of performance, service, Excellent service, quick delivery, plusgood product
Date published: 2026-06-08
  • y_2026, m_8, d_12, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_14
  • loc_en_CA, sid_VFA-1, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 7ms
  • REVIEWS, PRODUCT

What are the standard conditions? 70°F and 14.7 psia?

Asked by: SteveInNC
That is correct. These are calibrated at ambient conditions (70 F, 14.7 PSIA).
Answered by: AD Application Engineer
Date published: 2025-09-11

Good morning I would like information about the type of stainless steel used in the connections and valve. Stainless steel 316, 304?

Asked by: mBorges
Thank you for your inquiry. Please contact us directly at tech@dwyeromega.com
Answered by: Application Engineer CB
Date published: 2025-05-16

Will the Dwyer rotameter with SS metering valve (Model: VFB-66-SSV-PF) with 1-10 LPM range be suitable for the below design conditions? Design Pressure (Max/Min) – 145/135 psi-g Design Temperature (Max/Min) – 90/ 60 °F Service – Oil Free Air

Asked by: Guruprasad
Hello, No, as these units have a max pressure rating of 100 PSIG.
Answered by: AD Application Engineer
Date published: 2026-02-25
  • y_2026, m_8, d_13, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_VFA-1, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 19ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration