Product Overview
- Applications Environmental Monitoring, Industrial and Manufacturing
- Battery Size and Type 3.6V Li-ion
- Clock Accuracy ± 8 s/day plus one sampling interval
- Compensated Temperature, Max 158 °F
- Compensated Temperature, Min -40 °F
- Electrical Connection Screw Terminal
- Materials Plastic
- Memory 1,048,000 Readings
- Number of Channels 8
- Operating Temperature, Max 160 °F
- Operating Temperature, Min -50 °F
- Relative Humidity 0 to 95%, Non-Condensing
- Resolution 12 bit
- Sensor Type One internal thermistor and seven for External Thermocouple
- Series ID Model-DL-8T
- Stop Modes Adjustable Logging Intervales
- Supply Power Note 3.6V Lithium Battery, Built-in
- Supply Power Type Battery
- System Requirements IBM compatible running Windows® 3.1, Windows® 95, Windows® 98, Windows® 2000, Windows® ME, Windows® NT, or Windows® XP
- Temperature Accuracy ± 1%
- Weight 5 oz
Supported Applications
The Model DL-8T Temperature Logger monitors and records temperature in eight different locations. It has a built-in sensor for local temperature monitoring and accepts seven external thermocouples in types J, K, T, S, or E, so a single self-powered, pocket-sized unit can cover a spread of measurement points. Part of the Series DL family of battery-powered loggers, it can work as a stand-alone unit or perform remote monitoring across a wide range of environmental and industrial applications.
- Multi-point temperature surveys, combining one internal channel with seven external thermocouple inputs.
- Environmental and industrial monitoring, using the logger stand-alone or for remote data collection.
- Networked monitoring with alarm dial-out, as the logger is network capable.
Recorded data is analyzed with software on an IBM-compatible PC; the required Windows software is sold separately.
Operating Conditions & Performance
The DL-8T provides eight channels — one for the internal thermistor and seven for external thermocouple inputs — and offers 12-bit resolution for finer measurements.
- Internal thermistor range: -40 to 158°F (-40 to 70°C).
- Accuracy: ±1% of full scale.
- Clock accuracy: ±8 seconds per day plus one sampling interval.
- Sampling rates: selectable from 0.04 seconds to once every 8 hours, using continuous (first-in, first-out) or stop-when-full (fill-then-stop) methods.
Memory holds 1,048,000 readings. The logger operates at 32 to 122°F (0 to 50°C), with an ambient operating range of -50 to 160°F (-45 to 70°C), 0 to 95% RH, non-condensing. Power is supplied by a built-in 3.6V lithium battery, connection is via a removable screw terminal, and the plastic-housed unit weighs 5 oz (110 g). It is CE marked.
Configuration Options
The DL-8T is a single configuration within the Series DL family, so its capability set is fixed: eight channels total, one internal thermistor plus seven external thermocouple inputs accepting types J, K, T, S, or E, and 12-bit resolution. There are no sub-variants that change channel count or sensor type; the flexibility comes from which thermocouple types and channels the user enables for a given application.
Key Product Differences
- DL-8T — eight-channel temperature logger with internal thermistor and seven external thermocouple inputs, 12-bit resolution, built-in 3.6V lithium battery, and 1,048,000-reading memory.