Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

DP3002-JKT

4-1/2 Digit Thermocouple Meters, 1/8 DIN

  • J, K or T Thermocouple Input
  • 0.05 deg/deg Cold-Junction Error
  • -138 to 1248°C Range
  • Five-Segment Linearization
DP3002-JKT
From C$ 470.00
4-1/2 Digit Thermocouple Meters, 1/8 DIN DP3002-JKT DP3002-JKT
loading all models
Product Overview
  • A/D Conversion Dual-slope technique
  • Accuracy ± 1.5 °C (± 2.7 °F) + 1 count
  • Calibration IEC 584-1 (IPTS-68)
  • Cutout Dimensions 45 x 92 mm
  • Depth Behind Panel 104 mm
  • Digital I/O Note Level: TTL or 5V CMOS compatible
  • Display Size 14.2 mm (0.56 in)
  • Display Type 4.5 Digit LED
  • Display Type Note Symbols: -1.8.8.8.8 Decimal Points: Four positions programmable by jumpers behind the lens or at connector Overrange Indication: Four least-significant digits flash
  • Enclosure Material Polycarbonate
  • Enclosure Ratings IP65, NEMA Type 4
  • Form factor 1/8 DIN
  • Front Bezel 96 W x 48 H x 5.1 D mm
  • Input Configuration Single-ended
  • Lead Resistance, Max Type K: 50 µdeg/deg/Ω, up to 2000 Ω, Current Break: 300 nA
  • Noise Rejection NMR, SIG HI to SIG LO: 70 dB, 50/60 Hz ;CMR, ANA GND to PWR GND: 120 dB, DC to 60 Hz ;CMV, ANA GND to PWR GND: 1500 Vp per HV test, 354 Vp per IEC spacing
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min 0 °C
  • Output Configurations Analog Current/Voltage
  • Output Configurations Note Voltage: 1 mV/deg Calibration Error: ±1.5 mV on °C, ±2.7 mV on °F Current: 1 mA max Source Resistance: 68 Ω
  • Polarity Bipolar
  • Power Consumption 3.7 W
  • Reading Rate 2.5 samples/sec
  • Relative Humidity 95% at 40°C (non-condensing)
  • Sensor Break Detection Positive overrange (upscale)
  • Sensor/Transmitter Power 4.7 Vdc and -4.7 Vdc ±5%, 10 mA max
  • Series ID DP3002-JKT
  • Step Response 1 sec
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note AC Voltages: 115 or 230 Vac ±15% AC Frequency: 49 to 440 Hz DC Voltages: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp Power Consumption: 2.5 W
  • Supply Voltage 9 to 56 Vdc, 115 to 230 Vac
  • Temperature Coefficient ±0.05 deg/deg
  • Temperature Measurement Range -105 to 1248°C
  • Thermal Span Effect ±0.01% of reading/°C
  • Warm-Up to Rated Accuracy 20 min
  • Weight 425 g

Supported Applications

The Omega DP3002 series comprises 4½ digit thermocouple meters in a 1/8 DIN format, designed for indication-only applications. These process indicators accept Type J, K, or T thermocouple inputs and feature five-segment linearization to display temperature readings on a bright red LED display.

Operating Conditions & Performance

The series provides measurement ranges specific to the selected thermocouple type and scale. Available input spans include -138 to 760°C, -216 to 1400°F for Type J; -105 to 1248°C, -157 to 1999°F for Type K; and -112 to 400°C, -170 to 752°F for Type T. Accuracy is specified as ±1.5°C (±2.7°F) ±5 cts or ±0.01% of reading/°C depending on the configuration.

Performance characteristics include a resolution of 0.1°C or 0.1°F, which is jumper-selectable. The full-scale step response time is 1 s. Units operate within an ambient temperature range of 0 to 60°C and can be stored between -40 to 85°C. Humidity tolerance is rated at 95% at 40°C (non-condensing).

Configuration Options

The DP3002 series offers configurable options for power supply, display color, and environmental protection.

  • Power Supply: Standard models support 115/230 Vac (±15%, 49 to 440 Hz). Isolated DC options are available: 9 to 32 Vdc isolated to 300 Vp, or 26 to 56 Vdc isolated to 300 Vp.
  • Display: Standard units feature a red LED display with 14 mm (0.56") digits; a green LED display is available as an option (-G).
  • Housing & Protection: The enclosure utilizes 94V-0 UL-rated polycarbonate. An optional NEMA 4 (IP65) splash-proof lens cover provides additional protection.
  • Outputs: A linearized recorder output is available, providing a voltage of 1 mV/deg with a maximum current of 1 mA max.

Physical dimensions for the bezel are 96 W x 48 H x 5.1 mm D (3.78 x 1.89 x 0.20"). The depth behind the bezel is 104 mm (4.09"), requiring a panel cutout of 92 W x 45 mm H (3.62 x 1.77"). Electrical connections are made via a screw-terminal barrier strip.

Key Product Differences

Variants within the DP3002 series differ by thermocouple type, temperature range, power input, and display color. Model numbers follow the format: DP3002 - <Thermocouple Type & Range> - <Power Option> - <Display Color>. For example, model DP3002-KC1 denotes a 4½ digit Type K thermocouple meter with 115 Vac power and an input range of -105 to 1248°C.

The series is RoHS 2 compliant. Note that not all combinations of options may be valid; specific part numbers should be verified against the manufacturer's ordering guide.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 5ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration