Need assistance? Call us: 1-800-663-4209
HH147AU-Series
2 Channel Handheld 7 Thermocouple Types Data Logger USB output
Models In Stock
- Thermocouple Types K, J, T, E, R, S, N
- Large Backlit LCD with 5-Digit Display
- Dual LCD Displays T1, T2 and T1-T2
- Max, Min, Avg, Time, Rel and Data Hold Functions
HH147AU-Series
From
C$
741.80
Models In Stock
Product Overview
- Additional Features 1 MIN/MAX/AVG/REL/HOLD Functions , Auto Power-Off
- Battery life 1000 hr
- Data Interface USB
- Data Interface Note USB PC Serial Interface
- Display Type LCD
- Display Type Note Large Backlit LCD with 5-Digit Display
- Height 40 mm
- Length 155 mm
- Measurement Type Temperature
- Number of Measurements 2
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Relative Humidity, Max <80%
- Samples,Max 14000
- Series ID HH147AU-Series
- Software Compatibility Windows XP SP3/7/8/10
- Storage Temperature, Max 50 °C
- Storage Temperature, Min 0 °C
- Temperature Accuracy ± 0.05 %
- Temperature Measurement Note ITS-90
- Temperature Sensor Type Thermocouple
- Weight 170 g
- Width 56 mm
Supported Applications
The Omega HH147AU is a dual-channel handheld thermocouple thermometer designed for measuring temperature using K, J, T, E, R, S, or N type thermocouples. The device features USB connectivity for data logging and software installation. It is intended for indoor use in non-hazardous environments with Pollution degree 2.
Operating Conditions & Performance
The HH147AU supports the following measurement ranges by sensor type:
- K type: -200°C to 1372°C
- J type: -200°C to 1200°C
- T type: -200°C to 400°C
- E type: -200°C to 1000°C
- R type: 0°C to 1760°C
- S type: 0°C to 1760°C
- N type: -200°C to 1300°C
Accuracy is specified as ±0.5% of reading ±1 digit or ±1.5°C for K, J, T, E, R, S, N types. The resolution is 0.1°C / 0.1°F with a typical response time of 1 second. Ambient operating temperature ranges from 0°C to 50°C, and storage temperature spans -20°C to 60°C. Operating altitude is up to 2000M.
Approvals & Safety
The series carries CE approval with EMC compliance: EN61326-1; CISPR 11: Group 1, Class B. Warnings indicate the device should not be operated in environments with flammable gas or humid environments.
Configuration Options
The HH147AU features a dual LCD display for T1 and T2 readings with backlight capability. Functional capabilities include an alarm function, data hold, auto power off, relative value measurement, offset setting, and maximum/minimum/average value tracking.
Power & Connectivity
The unit is powered by a 9V alkaline battery or a 9V AC to DC adapter. Data output is provided via USB data output socket (DC 9V input). Thermocouple inputs utilize yellow, 2-pin connectors at terminals T1 and T2.
Accessories
The standard package includes:
- Meter
- User manual
- 9V alkaline battery
- Carrying case
- 9V AC to DC adaptor
- USB cable
- Installation disk
Key Product Differences
The HH147AU-Series is represented by the single model number guide HH147AU. The device housing material is plastic.
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 3 out of
5
by
Collin10 from
Essential connection detail buried in guide
Spent a couple of hours with our IT guy trying to figure out why it wouldn't connect. YOU MUST use the handheld device to turn on USB compatibility, found on page 12 of the User's Guide, although you will need to start the process on page 10 (section 5.11). If you don't see "USB" in small text on the bottom right corner of the device, your computer will not recognize the device. This step is inexplicably buried among information for less vital settings.
Another source of frustration is that the program logs the temperature data in Excel in a oC/oF/oK text column that defies easy plotting, even when oC is specified in general options. If there is a setting to change this I couldn't find it and ran out of patience to keep looking. I use =LEFT(D1,4) to grab the oC digits, copy and paste values, and finally convert to number.
Device has worked well so far, but the guides need a serious overhaul.
Date published: 2023-08-21
Rated 3 out of
5
by
Anonymous from
Works fine but user guides are terrible
The unit seems fine. Like the data logging feature and exporting to be sure. Be careful of the meter's user's guide, especially Section 5.11. The guide is not clear about how to get to the functions on each step. My employees couldn't figure out how to connect it to a PC. I figured out the unit by trial and error. The software instructions are even worse. I am writing a comprehensive work instruction for my employees so they can easily use it.
English was clearly not the first language for the user's guides
Date published: 2020-04-01
Rated 4 out of
5
by
utropico from
Nice tool
We bought it a month ago, fair enough and we're pleased with it. Perhaps it needs a better user manual but after some testings we were able to identify how some parameters should be configured.
Date published: 2017-07-17
Rated 5 out of
5
by
Quinn from
Simple and Works
Works well. Just enable USB mode on the meter and off-loading data to your PC is quick and easy.
Date published: 2024-02-22
Rated 1 out of
5
by
Jwss from
Does not link with our computer
Had our IT guy spend an hour trying to get the unit to be seen on the computer. Never got it to work. Gave up.
Date published: 2017-12-14
What is the minimum recording time for this datalogger.
The HH147AU can be set to record 1 measurement per second minimum.
Date published: 2024-03-07
What is the part number for the AC Adapter?
Thank you for your inquiry Zman22222. Unfortunately, the HH147Au does not have an AC adaptor because this unit is battery operated.
Date published: 2022-02-16
What is the response time for the thermocouples?
The probe included is a 30 AWG wire diameter with a beaded junction so it will be about 1.5 seconds to reach the full temperature measured.
Date published: 2020-04-04
What are the part numbers for type J, K and T connectors that fit this logger?
The connectors used would be the miniature versions SMPW-J-M, SMPW-K-M and SMPW-T-M.
Date published: 2024-03-07
Is the output of this logger also able to work with Windows 11?
The Software for the HH147AU is approved compatible up to OS10.
Date published: 2024-03-07
The thermometer is not detected by software, I already install all properly. "No COM" is not removed.
Please contact the Temperature Engineering group for assistance temp@omega.com or 1-800-872-9436
Date published: 2020-06-15
Does this require special software to pull the data from and can this work on Windows 11
The Software comes with the meter and is rated up for use up to OS10 but customers have used it with OS11 without any problems reported.
Date published: 2024-12-13
Can I calibrate this reader myself?
You can set an offset against a reference to adjust to that standard but full calibration would require the unit be return to Omega.
Date published: 2021-08-03