HH506A-HH506RA

2 Channel 7 Thermocouple Types Datalogger Water/Splash Proof

  • 2-Channel Temperature Measuring
  • 7 Thermocouple Types
  • Triple Display with Setable Backlight
  • Triple Display with Setable Backlight
HH506A-HH506RA
From C$ 387.81
2 Channel 7 Thermocouple Types Datalogger Water/Splash Proof HH506A-HH506RA HH506A-HH506RA
loading all models
Product Overview
  • Additional Features 1 MIN/MAX/REL/Auto Power-Off/HOLD Functions
  • Display Type LCD
  • Display Type Note Backlight LCD, 19999 Digits
  • Form factor Handheld
  • Height 53 mm
  • Length 192 mm
  • Measurement Type Temperature
  • Number of Measurements 2
  • Operating Time Real Time
  • Samples,Max 1024
  • Series ID HH506A-HH506RA
  • Temperature Accuracy ± 0.3 °C (± 0.54 °F)
  • Temperature Accuracy Note ± (0.05% rdg + 0.3°C)
  • Temperature Measurement, Max 1767 °C
  • Temperature Measurement, Min -210 °C
  • Temperature Resolution 1 °C, 0.1 °C
  • Temperature Sensor Type Thermocouple
  • Width 91 mm

Supported Applications

The Omega HH506 series comprises portable, dual-input digital thermometers and data loggers designed for temperature measurement using external thermocouples. The series supports seven thermocouple types: K, J, T, E, R, S, and N. These handheld units are engineered to measure temperatures across a broad envelope ranging from -210°C (-346°F) up to 1767°C (3212°F), depending on the selected sensor type.

The HH506RA model includes an RS-232C interface and software for uploading data to a PC, while the HH506A functions as a basic dual-input data logger. Both models feature water/splash resistance (NEMA 4X/IP56) and dustproof construction.

Operating Conditions & Performance

The series operates within an ambient temperature range of 0°C to 50°C (32°F to 122°F) with humidity below 80% R.H. Storage conditions are specified as -20°C to 60°C (-4°F to 140°F) at less than 70% R.H.

Measurement accuracy varies by thermocouple type and temperature range:

  • K, J, T, E Types: ±(0.05% rdg + 0.3°C) on -50 to 1370°C; ±(0.05% rdg + 0.7°C) on -210 to -50°C.
  • N Type: ±(0.05% rdg + 0.8°C) on -50 to 0°C; ±(0.05% rdg + 0.4°C) on 0 to 1300°C.
  • R, S Types: ±(0.05% rdg + 2°C) on 0 to 1767°C.

The device complies with NIST-ITS 90 standard reference temperature/voltage tables. Input protection is rated for a maximum of 24V dc or 24V ac rms on any combination of input pins. The reading rate is specified as 2.5 times per second.

Measurement Ranges by Type

  • K-Type (0.1 resolution): -200°C to 1372°C (-328°F to 2501°F)
  • J-Type (0.1 resolution): -210°C to 1200°C (-346°F to 2192°F)
  • T-Type (0.1 resolution): -200°C to 400°C (-328°F to 752°F)
  • E-Type (0.1 resolution): -210°C to 1000°C (-346°F to 1832°F)
  • R/S-Type (1° resolution): 0°C to 1767°C (32°F to 3212°F)
  • N-Type (0.1 resolution): -50°C to 1300°C (-58°F to 2372°F)

Configuration Options

The series offers configurable data logging capacities and interface options depending on the model selected.

  • Data Logging Capacity: The HH506A supports a save mode for 128 samples with time stamps. The HH506RA expands this capability to store up to 1024 records in data logging mode.
  • The HH506RA includes an RS-232C interface and compatible software (Windows 98, NT/2000). An optional USB cable and software package are available for the HH506RA. The HH506A does not include a data upload interface.
  • Both models feature a triple display with backlit LCD panels showing main readings (4 1/2 digit, max reading of 19999), date/time, or the difference value between T1 and T2 inputs.

The units accept standard miniature thermocouple connectors with flat blades spaced 7.9 mm center to center. A free Type K beaded thermocouple (4 feet) is supplied with each unit; additional probes are sold separately.

Available Accessories and Options

  • USB cable and software for Windows 98/NT/2000 (for HH506RA).
  • Soft carrying case.
  • 150 mm (6") long, 1/8" diameter stainless steel Type K probe with a retractable cable expanding to 300 mm (12").
  • Utility handle probe, 300 mm (12").
  • NIST-traceable calibration with points.
  • Replacement 9V alkaline battery.

Key Product Differences

The primary distinction between the two models in this series is data connectivity and storage capacity. The HH506RA includes an RS-232C interface, software for PC upload, and a 1024-record logging memory. In contrast, the HH506A lacks the communication port and software but retains dual-channel measurement with a 128-sample save mode.

Both models share identical physical dimensions of approximately 192 mm (H) x 91 mm (W) x 53 mm (D), operate on a standard 9V battery, and feature the same NEMA 4X/IP56 enclosure rating. The HH506RA weight is listed as approximately 255 g (9 oz).

Accessories

cables

USB SW + CABLE: WIN 98;2000;XP
C$79.50 / each
24 In Stock

consumables

sensors

K Type Immersion Probe, Grounded, 304 Stainless Steel, 0.125 in Diameter, 12 in Length, Retractable Cable
C$116.12 / each
2 In Stock
General Purpose Thermocouple Probes With Miniature Plug Connector
C$106.70 / each
174 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

can I just log T1 (and not T2)?

Asked by: engtech
Both T1 and T2 are recorded there is no way to adjust for one or the other.
Answered by: ANBENG
Date published: 2020-04-04

IS THE OMEGA® HH506A FDA COMPLIANT, TO THE FDA 21 CFR Part II, GMP, GLP?

Asked by: Anonymous
Thank you for your inquiry. Unfortunately, this product is not FDA compliant.
Answered by: Application Engineer JB
Date published: 2019-09-17

I have a HH506R to which I have 2 type K thermocouples (CH+, AL-), the T2 display is stuck as type E and won't change when I press the "type" button even when the main display is showing T2. Kindly help. ( Sorry if not appropriate thread for this Q)

Asked by: srikar
Thank you for your inquiry. Please try removing the battery, then re-install the battery and try to reset the unit, and reprogram the thermocouple type. If you still have issues, feel free to call our temperature group at 1-888-826-6342 or email to temp@omega.com
Answered by: Application Engineer JB
Date published: 2021-12-03

Can I download the software for the HH506RA? my computer does not have a CD drive

Asked by: Annemieke
Yes the SW can be found on Omega's FTP site for temperature products https://www.omega.com/en-us/ftp
Answered by: ApplicationEngineerANB
Date published: 2020-11-05

Is there a video showing how to setup and use the HH506RA temperature logger?

Asked by: SonOfLightning
There is not a video for the operation of the HH506RA but Applications Engineers are available by phone to contact and discuss features as needed.
Answered by: ApplicationEngineerANB
Date published: 2024-05-29

Is it still possible to download the software for the HH506RA? (and where can we find the link)

Asked by: Pawel
From any of the pages on www.dwyeromega.com click on resources then software. On this link there is an index and you can access the HH506RA Software.
Answered by: ApplicationsEngineerANB
Date published: 2025-09-28

Is there an option to download logged data to my PC? It seems I couldn't find an I/O interface

Asked by: ChEngineer Boy
The HH506RA comes with the Software and communication cable when purchased which allows downloading to computers. If it was lost you can order HH506RA-USB-SW to replace it.
Answered by: ApplicationEngineerANB
Date published: 2020-07-13

How often the HH506RA should be calibrated and how should it be calibrated?

Asked by: Jack001
Thank you for your inquiry. We recommend an annual calibration (once a year).
Answered by: Engineer CB
Date published: 2020-07-16
  • y_2026, m_8, d_2, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_10
  • loc_en_CA, sid_HH506A, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 8ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration