1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
HH506A-HH506RA
2 Channel 7 Thermocouple Types Datalogger Water/Splash Proof
Models In Stock
- 2-Channel Temperature Measuring
- 7 Thermocouple Types
- Triple Display with Setable Backlight
- Triple Display with Setable Backlight
HH506A-HH506RA
From
C$
377.61
Models In Stock

Product Overview
- Additional Features 1 MIN/MAX/REL/Auto Power-Off/HOLD Functions
- Display Type LCD
- Display Type Note Backlight LCD, 19999 Digits
- Form factor Handheld
- Height 53 mm
- Length 192 mm
- Measurement Type Temperature
- Number of Measurements 2
- Operating Time Real Time
- Samples,Max 1024
- Temperature Accuracy ± 0.3 °C (± 0.54 °F)
- Temperature Accuracy Note ± (0.05% rdg + 0.3°C)
- Temperature Measurement, Max 1767 °C
- Temperature Measurement, Min -210 °C
- Temperature Resolution 1 °C, 0.1 °C
- Temperature Sensor Type Thermocouple
- Width 91 mm
Description
The OMEGA HH500RA is a low cost, feature-packed, portable, digital thermometer that measures K, J, R, S, T, E and N thermocouples. The unit has datalogging capacity in the save mode of 128 samples with real-time data and in the datalogging mode of 16 sets, with a maximum data capacity of 1024 records. Easy to use set-up instructions allow the user to measure a broad range of T/Cs, MAX/MIN, AVG, REL, Hold Function, T1/T2.SPECIFICATIONS
Temperature Range:
K Type: (0.1°, 1° for above 2000°F) -200 to 1372°C (-328 to 2501°F)
J Type: (0.1°, 1° for above 2000°F) -210 to 1200°C (-346 to 2192°F)
T Type: (0.1°) -200 to 400°C (-328 to 752°F)
E Type: (0.1°) -210 to 1000°C (-346 to 1832°F)
R Type: (1°) 0 to 1767°C (32 to 3212°F)
S Type: (1°) 0 to 1767°C (32 to 3212°F)
N Type: (0.1°, 1° for above 2000°F) -50 to 1300°C (-58 to 2372°F)
According to temperature standard ITS-90
Accuracy:
K/J/T/E Type:
± (0.05% rdg + 0.3°C) on -50 to 1370°C
± (0.05% rdg + 0.7°C) on -50 to -210°C
± (0.05% rdg + 0.6°F) on -58 to 2501°F
± (0.05% rdg + 1.4°F) on -58 to -346°F
N Type:
± (0.05% rdg + 0.8°C) on -50 to 0°C
± (0.05% rdg + 0.4°C) on 0 to 1300°C
± (0.05% rdg + 1.6°F) on -58 to 32°F
± (0.05% rdg + 0.8°F) on 32 to 2372°F
R/S Type:
± (0.05% rdg + 2°C) on 0 to 1767°C
± (0.05% rdg + 4°F) on 32 to 3212°F
Resolution: 0.1°C/1°C (0.1°F/1°F)
Power: 9 V battery (included)
Datalogger Capacity:
Save Data: 128 samples with time stamp
Datalogger: 1024 data capacity(interval 1 sec to 23:59:59)
PDFs & Manuals
Accessories
So ft carrying case for HH500 series
$20.20
0 In Stock