Model-473B

Anémomètre à volets de 100 mm pour la vitesse de l'air, la température et l'humidité - Usage CVC

100 mm Vane Thermo-Anemometer for Air Velocity, Temp & Humidity - HVAC Use
Modèles en stock
  • Compatible with Dwyer AP1 thermo-anemometer and RP1 thermo-hygrometer wired probes (sold separately)
  • Measure air velocity, volumetric air flow, temperature, and humidity with the included 100 mm vane probe
  • Visible in any condition due to high contrast and backlit LCD display
  • Able to store up to 99 readings for later evaluation
Model-473B
À partir de C$ 910.60
Modèles en stock
100 mm Vane Thermo-Anemometer for Air Velocity, Temp & Humidity - HVAC Use Model-473B Model-473B
loading all models
Aperçu du produit
  • Accuracy Detail Air velocity: ±1.5% of reading ±20 FPM (±0.1 m/s) [0.25 to 10 m/s]; ±1.5% of reading ±40 FPM (±0.2 m/s) [10 to 20 m/s]; ±1.5% of reading ±60 FPM (±0.3 m/s) [20 to 25 m/s], Temperature: ±0.9°F @ 77°F (±0.5°C @ 25°C), Relative humidity: ±2% @ 77°F (25°C) [10 to 90% RH]; ±4% [0 to 10, 90 to 100% RH]
  • Air Velocity Accuracy ±1.5%
  • Air Velocity, Max 5000 FPM
  • Air Velocity, Min 40 FPM
  • Applications HVAC, Industrial and Manufacturing
  • Battery Size and Type Alkaline 9V
  • Cable Length 28 in
  • Cable Length Note 28˝ (71 cm) retracted; 6´ (18.3 m) extended
  • Display Note 4.5 digit backlit display; 19,999 in selected flow units
  • Display Type Backlit LCD
  • Humidity Accuracy ± 2% RH
  • Humidity Range 0 to 100% RH
  • Humidity Response Time 1.5 s
  • Materials Anodized Aluminum
  • Media Compatibility Clean dry air / inert gas, Inert / non-reactive gases, Clean Dry Air, Helium, Nitrogen, Non-Corrosive Dry Gases, Argon, Carbon dioxide
  • Operating Temperature, Max 125 °F
  • Operating Temperature, Min 5 °F
  • Probe Length 8 in
  • Process Temperature, Max 212 °F
  • Process Temperature, Min -20 °F
  • Response Time Air Velocity: 1 s, Air Volume: 1 s, Temperature: 1.5 s
  • Series ID Model-473B
  • Supply Power Note 9 V alkaline battery, installed non-functional, user replaceable
  • Supply Power Type Battery
  • Temperature Accuracy ± 0.9 °F
  • Temperature Measurement Range - 20 to 212 °F
  • Weight 18.4 oz

Supported Applications

The Dwyer Model 473B is a handheld test instrument designed to measure air velocity, volumetric air flow, temperature, and relative humidity. The series serves applications requiring measurement in dry, clean air environments.

  • Air velocity monitoring using a vane probe
  • Volumetric airflow calculation
  • Temperature sensing for process or ambient conditions
  • Relative humidity assessment

Operating Conditions & Performance

The Model 473B operates within specific environmental and measurement limits. The device features a 4.5 digit backlit display and is powered by a user-replaceable 9 V alkaline battery.

Measurement Ranges:

  • Air velocity: 40 to 5000 FPM (0.2 to 25 m/s)
  • Volumetric air flow: 19,999 in selected flow units
  • Temperature: -20 to 212°F (-29 to 100°C)
  • Relative humidity: 0 to 100% RH

Ambient and Process Limits:

  • Process temperature limits: -20 to 212°F (-29 to 100°C)
  • Ambient operating temperature: 5 to 125°F (-15 to 51°C)

Accuracy Specifications:

  • Air velocity: ±1.5% of reading ±20 FPM (±0.1 m/s) [0.25 to 10 m/s]; ±1.5% of reading ±40 FPM (±0.2 m/s) [10 to 20 m/s]; ±1.5% of reading ±60 FPM (±0.3 m/s) [20 to 25 m/s]
  • Temperature: ±0.9°F @ 77°F (±0.5°C @ 25°C)
  • Relative humidity: ±2% @ 77°F (25°C) [10 to 90% RH]; ±4% [0 to 10, 90 to 100% RH]

Response Times:

  • Air velocity: 1 s
  • Volumetric air flow: 1 s
  • Temperature: 1.5 s
  • Relative humidity: 1.5 s

Configuration Options

The Model 473B series includes a stainless steel 100 mm vane probe with an insertion length of 8" (203 mm). The housing is constructed from extruded aluminum, providing protection for the electronics while maintaining a lightweight profile. A comfortable hand grip is integrated into the probe design.

Probe and Cable Configuration

  • Vane material: Anodized aluminum
  • Cable length: 28" (71 cm) retracted; 6' (18.3 m) extended

Data Storage and Display

The instrument can store up to 99 readings.

Key Product Differences

The Model 473B is part of a family that includes the Models 471B-1 (hot wire thermo-anemometer) and 485B-1 (thermo-hygrometer). The series supports interchangeable AP1, RP1, and VP1 probes which are automatically recognized by the handheld unit without requiring recalibration.

Calibration Options

  • -COC: Certificate of calibration (Model 473B only)
  • -FC: Factory calibration (Model 473B only)
  • -NIST: NIST traceable calibration certificate

The Model 473B carries CE approval. The unit is not field serviceable; repairs require returning the product to Dwyer Instruments, Inc.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
en_CA
Enregistrer la configuration