Besoin d'aide? Appelez-nous: 1-800-663-4209
Model-473B
Anémomètre à volets de 100 mm pour la vitesse de l'air, la température et l'humidité - Usage CVC
100 mm Vane Thermo-Anemometer for Air Velocity, Temp & Humidity - HVAC Use
Modèles en stock
- Compatible with Dwyer AP1 thermo-anemometer and RP1 thermo-hygrometer wired probes (sold separately)
- Measure air velocity, volumetric air flow, temperature, and humidity with the included 100 mm vane probe
- Visible in any condition due to high contrast and backlit LCD display
- Able to store up to 99 readings for later evaluation
Model-473B
À partir de
C$
910.60
Modèles en stock
Aperçu du produit
- Accuracy Detail Air velocity: ±1.5% of reading ±20 FPM (±0.1 m/s) [0.25 to 10 m/s]; ±1.5% of reading ±40 FPM (±0.2 m/s) [10 to 20 m/s]; ±1.5% of reading ±60 FPM (±0.3 m/s) [20 to 25 m/s], Temperature: ±0.9°F @ 77°F (±0.5°C @ 25°C), Relative humidity: ±2% @ 77°F (25°C) [10 to 90% RH]; ±4% [0 to 10, 90 to 100% RH]
- Air Velocity Accuracy ±1.5%
- Air Velocity, Max 5000 FPM
- Air Velocity, Min 40 FPM
- Applications HVAC, Industrial and Manufacturing
- Battery Size and Type Alkaline 9V
- Cable Length 28 in
- Cable Length Note 28˝ (71 cm) retracted; 6´ (18.3 m) extended
- Display Note 4.5 digit backlit display; 19,999 in selected flow units
- Display Type Backlit LCD
- Humidity Accuracy ± 2% RH
- Humidity Range 0 to 100% RH
- Humidity Response Time 1.5 s
- Materials Anodized Aluminum
- Media Compatibility Clean dry air / inert gas, Inert / non-reactive gases, Clean Dry Air, Helium, Nitrogen, Non-Corrosive Dry Gases, Argon, Carbon dioxide
- Operating Temperature, Max 125 °F
- Operating Temperature, Min 5 °F
- Probe Length 8 in
- Process Temperature, Max 212 °F
- Process Temperature, Min -20 °F
- Response Time Air Velocity: 1 s, Air Volume: 1 s, Temperature: 1.5 s
- Series ID Model-473B
- Supply Power Note 9 V alkaline battery, installed non-functional, user replaceable
- Supply Power Type Battery
- Temperature Accuracy ± 0.9 °F
- Temperature Measurement Range - 20 to 212 °F
- Weight 18.4 oz
Supported Applications
The Dwyer Model 473B is a handheld test instrument designed to measure air velocity, volumetric air flow, temperature, and relative humidity. The series serves applications requiring measurement in dry, clean air environments.
- Air velocity monitoring using a vane probe
- Volumetric airflow calculation
- Temperature sensing for process or ambient conditions
- Relative humidity assessment
Operating Conditions & Performance
The Model 473B operates within specific environmental and measurement limits. The device features a 4.5 digit backlit display and is powered by a user-replaceable 9 V alkaline battery.
Measurement Ranges:
- Air velocity: 40 to 5000 FPM (0.2 to 25 m/s)
- Volumetric air flow: 19,999 in selected flow units
- Temperature: -20 to 212°F (-29 to 100°C)
- Relative humidity: 0 to 100% RH
Ambient and Process Limits:
- Process temperature limits: -20 to 212°F (-29 to 100°C)
- Ambient operating temperature: 5 to 125°F (-15 to 51°C)
Accuracy Specifications:
- Air velocity: ±1.5% of reading ±20 FPM (±0.1 m/s) [0.25 to 10 m/s]; ±1.5% of reading ±40 FPM (±0.2 m/s) [10 to 20 m/s]; ±1.5% of reading ±60 FPM (±0.3 m/s) [20 to 25 m/s]
- Temperature: ±0.9°F @ 77°F (±0.5°C @ 25°C)
- Relative humidity: ±2% @ 77°F (25°C) [10 to 90% RH]; ±4% [0 to 10, 90 to 100% RH]
Response Times:
- Air velocity: 1 s
- Volumetric air flow: 1 s
- Temperature: 1.5 s
- Relative humidity: 1.5 s
Configuration Options
The Model 473B series includes a stainless steel 100 mm vane probe with an insertion length of 8" (203 mm). The housing is constructed from extruded aluminum, providing protection for the electronics while maintaining a lightweight profile. A comfortable hand grip is integrated into the probe design.
Probe and Cable Configuration
- Vane material: Anodized aluminum
- Cable length: 28" (71 cm) retracted; 6' (18.3 m) extended
Data Storage and Display
The instrument can store up to 99 readings.
Key Product Differences
The Model 473B is part of a family that includes the Models 471B-1 (hot wire thermo-anemometer) and 485B-1 (thermo-hygrometer). The series supports interchangeable AP1, RP1, and VP1 probes which are automatically recognized by the handheld unit without requiring recalibration.
Calibration Options
- -COC: Certificate of calibration (Model 473B only)
- -FC: Factory calibration (Model 473B only)
- -NIST: NIST traceable calibration certificate
The Model 473B carries CE approval. The unit is not field serviceable; repairs require returning the product to Dwyer Instruments, Inc.
PDF & Manuels