Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

HH370-Series

1 Channel RTD IP67 Waterproof Temperature Meter with Probe

Models In Stock
  • IP67 Waterproof Construction
  • NIST-Traceable Certificate Included (No Points)
  • Selectable Pt100 or Pt1000 Input
  • Max/Min/Average Temperature Recording
HH370-Series
From C$ 878.61
Models In Stock
1 Channel RTD IP67 Waterproof Temperature Meter with Probe HH370-Series HH370-Series
loading all models
Product Overview
  • Battery life 100 hr
  • Height 150 mm
  • Length 30 mm
  • Measuring Temperature Range, Max 300 °C
  • Measuring Temperature Range, Min -100 °C
  • Number of Channels 1
  • Operating Temperature Note Operating Temperature/Humidity:0 to 50°C (32 to 122°F); 0 to 80% RH
  • Power Consumption 0.53 mA
  • Probe Dimensions Note Approx 120 mm (4.72")
  • Probe Length 120 mm
  • Relative Humidity, Max 0.8
  • Relative Humidity, Min 0%
  • Sampling Rate 2 Hz (2 updates/second)
  • Series ID HH370-Series
  • Sheath Length 100 mm
  • Sheath Material 304 Stainless Steel
  • Storage Temperature, Max 60 °C
  • Storage Temperature, Min -10 °C
  • Storage Temperature Note Storage Temperature and Humidity:-10 to 60°C (14 to 140°F); 0 to 80% RH
  • Supply Power Note Maximum Voltage at Temperature Input: 60 Vdc or 24 Vrms AC 
  • Supply Voltage 60 Vdc
  • Temperature Accuracy ± 0.1% of rdg + 0.4 °C
  • Temperature Accuracy Note Accuracy (at 23 ± 5°C): ± 0.1% of rdg + 0.4°C (± 0.1% of rdg + 0.8°F) Probe Accuracy : IEC751, Class A ± 0.15°C ± 0.002t (t = measurement temperature) 
  • Temperature Coefficient For ambient temperatures from 0 to 18°C and 28 to 50°C, add 0.01% of rdg + 0.03°C or 0.01% of rdg + 0.06°F
  • Temperature Resolution 0.1 °C
  • Temperature Sensor Type RTD
  • Weight 175 g
  • Weight Note 175 g (6.2 oz)
  • Width 66 mm

Supported Applications

The Omega HH370-Series is a digital RTD thermometer designed for industrial temperature measurement applications. It operates with platinum-type Resistance Temperature Detector (RTD) sensors, specifically Pt-100 and Pt-1000 elements.

Operating Conditions & Performance

The series measures temperatures across two defined ranges: -100°C ~ 300°C (-148°F ~ 572°F). Accuracy is specified as ±(0.1% reading + 0.4°C) for the Celsius range and ±(0.1% reading + 0.8°F) for the Fahrenheit range; this specification excludes probe error, which must be referenced separately from the probe accuracy data sheet.

The device features a resolution of 0.1°C or 0.1°F on its 4-digit LCD display. It is rated IP67 for enclosure protection and operates within an ambient temperature range of 0°C ~ 50°C (32°F ~ 122°F) at humidity levels between 0 ~ 80% RH. Storage conditions are defined as -10°C to 60°C (14°F ~ 140°F).

Configuration Options

The HH370-Series is powered by three size AAA batteries at 1.5V each. The unit measures approximately 150 x 66 x 31mm and weighs about 175g.

  • Sensor Compatibility: Designed for Pt-100 (Class A) and Pt-1000 probes.
  • Housing & Protection: IP67 waterproof rating suitable for industrial environments.
  • Power Source: Battery operated (3 x 1.5V AAA).
  • Accessories: Connection cables are available as optional accessories alongside the Pt-100 probe and instruction menu.

Key Product Differences

The series is identified by the model code HH370. The product overview notes that these devices carry CE, ISO 9001, and ISO 9002 certifications. A specific warning states that these products are not designed for use in human applications.

Accessories

SPARE WATERPROOF CONNECTOR
C$30.91 / each
0 In Stock

sensors

RTD SURFACE SENSOR ASSEMBLY. PT100
C$148.26 / each
16 In Stock
OPTIONAL PROBE
C$168.35 / each
0 In Stock
Rated 5 out of 5 by from Stable, accurate and surprise extra This unit has excellent accuracy specs and works perfect for the narrow temperature range I need it for. Not mentioned on the website description was a built in function to memorize a reference temp and monitor the change in temperature. This is perfect for my application and I’m very pleased with the unit.
Date published: 2018-01-17
Rated 5 out of 5 by from The HH370 is just what I needed I bought this temperature meter about a month ago. I needed to insure that a low cost digital thermometer was measuring correctly. The HH370 allowed me to quickly and easily confirm the temperature measurements. I plan to use the HH370 as a temperature standard which will allow me to adjust other low cost temperature controllers and meters to insure that they are measuring accurately. I did purchase the small carrying bag along with the meter. I was disappointed with the bag due to the fact that the probe will not fit in the bag. The probe is too long. This tends to render the bag useless since I prefer to keep the meter and the probe together as one unit.
Date published: 2017-11-01
  • y_2026, m_7, d_30, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_HH370, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Can I order the HH370 RTD Thermometer with its probe calibrated at two points 0 & 100 C with NIST cert included ?

Asked by: Anonymous
Calibrating at customer specific temperatures needs to be priced by the Temperature Engineering group. You can send your request to temp@omega.com and someone will assist you.
Answered by: ApplicationEngineerANB
Date published: 2021-06-04

What is the probe material of construction of the contacting surface?

Asked by: Nicole
The probe section that houses the temperature sensing element is made from 304 Stainless Steel.
Answered by: ApplicationEngineerANB
Date published: 2022-07-20

Can RTD Pt100 &amp handheld measure when extend the Rtd PT100 with cable to 100m far away? Is it suitable with an explosion proof ExiaI?

Asked by: Phuc
The meter and probe are an integral system for this meter and there are no extension cables offered. In general it would not be recommended to run long lengths of RTD cable as the wire would add additional Resistance affecting the accuracy of the measurement.
Answered by: ApplicationEngineerANB
Date published: 2020-06-25
  • y_2026, m_7, d_30, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_HH370, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration