Models In Stock
  • New Strain Gage Version is Available
  • Built-In USB Programming Port
  • Modular Output Modules
  • Universal Process, Voltage, Current, Resistance and Temperature Inputs
DP63100-series
From C$ 1,223.41
Models In Stock
1/8 DIN Universal Process & Strain Gage Panel Meter with USB DP63100-series DP63100-series
loading all models
Product Overview
  • A/D Conversion 24 bit resolution
  • Accuracy Detail Thermocouple Accuracy:;Type T: 2.1°C;Type E: 2.4°C;Type J: 2.3°C;Type K: 3.4°C;Type R: 4.0°C;Type S: 4.0°C;Type B: 5.7°C and 4.4°C;Type N: 3.1°C;Type C (W5/W26): 6.1°C ;RTD Accuracy:;100 Ω Pt alpha = 0.00385: 1.6°C;100 Ω Pt alpha = 0.003919: 1.6°C;120 Ω Nickel alpha = 0.00672: 0.5°C;10 Ω Copper alpha = 0.00427: 0.9°C;Current Inputs Accuracy:;±250 µADC: 0.12% of reading +0.04 µA, ;±2 mADC:0.12% of reading +0.4 µA, ;±20 mADC: 0.12% of reading +4 µA, ;±200 mADC: 0.15% of reading +40 µA, ;±2 ADC: 0.7% of reading +0.4 mA;Voltage Inputs Accuracy:;±250 mVdc: 0.12% of reading +40 μV,;±2.0 Vdc: 0.12% of reading +0.4 mV, ;±10 Vdc: 0.12% of reading +4 mV ;±25 Vdc: 0.12% of reading +4 mV, ;±100 Vdc: 0.12% of reading +40 mV, ;±200 Vdc: 0.12% of reading +40 mV;Resistance Inputs Accuracy:;100 Ω: 0.2% of reading +0.04 Ω, ;1000 Ω: 0.2% of reading +0.4 Ω, ;10 Ω: 0.2% of reading +1.5 Ω
  • Altitude Up to 2000m (6561 ft)
  • Cutout Dimensions 45 x 92 mm
  • Decimal Selection 4-Position
  • Digital Input Two Programmable User Inputs
  • Display Range -199999 to 999999
  • Display Size 18 mm (0.71 in)
  • Display Type LCD
  • Display Type Note Display: Negative image LCD Top Line: 6 digit, 18 mm (0.71"), with tri-color backlight (red, green or orange) Display Range: -199999 to 999999; Bottom Line: 9 digit, 8.9 mm (0.35"), with green backlight Display Range: -199,999,999 to 999,999,999
  • Electrical Connection Screw Terminal
  • Enclosure Ratings IP65, NEMA Type 4X
  • Form factor 1/8 DIN
  • Frequency 50/60 Hz
  • Height 49.53 mm
  • Input Type Quarter-bridge, Half-bridge, Full-bridge
  • Input Voltage ± 24 mVDC, ± 240 mVDC
  • Isolation 2300 Vrms for 1 min to all inputs and outputs.
  • Keypad 3 programmable function keys, 5 keys total
  • Length 105 mm
  • Linearization Points Selectable from 2 to 16
  • Measuring Range Thermocouple: Type T: -200 to 400 °C;Type E: -200 to 750 °C;Type J: -200 to 760 °C;Type K: -200 to 1250 °C;Type R: 0 to 1768 °C;Type S: 0 to 1768 °C;Type B: 150 to 300 °C and 300 to 1820 °C;Type N: -200 to 1300 °C;Type C (W5/W26): 0 to 2315 °C ;RTD: 100 Ω Pt alpha = 0.00385: -200 to 850 °C;100 Ω Pt alpha = 0.003919: -200 to 850 °C ;120 Ω Nickel alpha = 0.00672: -80 to 259 °C;10 Ω Copper alpha = 0.00427: -100 to 260 °C;Current Inputs: ± 250 µADC, ± 2 mADC, ± 20 mADC, ± 200 mADC, ± 2 ADC;Voltage Inputs: ± 250 mVdc, ± 2.0 Vdc, ± 10 Vdc, ± 25 Vdc, ± 100 Vdc, ± 200 Vdc;Resistance Inputs: 100 Ω, 1000 Ω, 10 Ω; Common Mode Range: 0 to +5 VDC
  • Memory Nonvolatile FRAM memory retains all programmable parameters and display values
  • Number of Inputs 1
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Operating Temperature Note 0 to 50°C (32 to 122°F) 0 to 45°C (32 to 113°F) with all three plug-in cards installed
  • Reading Rate 5 to 160/sec
  • Relative Humidity 0 to 85%
  • RTD Input Note Type: 3 or 4 wire, 2 wire can be compensated for lead wire resistance Excitation Current: 100 Ω Range: 136.5 µA ±10% 10 Ω Range: 2.05 mA ±10% Lead Resistance: 100 Ω Range: 10 Ω/lead maximum 10 Ω Range: 3 Ω/lead maximum Max Continuous Overload: 30V Excitation Power: Jumper selectable Transmitter Power: ±18 Vdc @ 50 mA Reference Voltage: ±2 Vdc, ±2%
  • RTD Input Range 3 or 4 wire, 2 wire can be compensated for lead wire resistance
  • Series ID DP63100-series
  • Storage Temperature, Max 60 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note AC Input: 50 to 250 Vac, 50/60 Hz, 14 VA DC Input: 21.6 to 250 Vdc, 8 W
  • Supply Voltage 50 to 250 Vac ,21.6 to 250 Vdc
  • Thermal Effects -199,999 to 999,999
  • Thermocouple Input Range Readout: Scale: ºF or ºC; Input Impedance: 20 MΩ; Lead Resistance Effect: 0.03 µV/Ω;Max Continuous Overvoltage: 30V
  • Thermocouple Lead Resistance, Max 100 Ω
  • Totalizer Time Base: sec,min,hr,day;Batch: Can accumulate (gate) input display from a user input;Time Accuracy: 0.01% typ.;Decimal Point: 0 to 0.0000;Scale Factor: 0.001 to 65.00;Low Signal Cut-Out: -199,999 to 999,999;Total: 6 digits on line 1; 9 digits on line 2;
  • Weight 226.8 g
  • Width 96.52 mm

Supported Applications

The Omega DP63100 is a universal input panel meter designed for industrial process monitoring and control. It accepts DC Voltage/Current, Process signals, Resistance, Temperature (Thermocouple and RTD), and Strain Gage inputs. The instrument features a dual-line tri-color display with programmable MAX/MIN reading memory and a signal totalizer (integrator). Configuration is performed via the built-in USB programming port using DP6-SOFT software.

Operating Conditions & Performance

The meter operates within an ambient temperature range of 0 to 50 °C with storage capability from -40 to 60 °C. It is rated for humidity up to 85% max. RH non-condensing and features a NEMA 4X/IP65 sealed front bezel suitable for harsh environments. The unit withstands operational shock of 25 g (10 g relay) at 11 msec in three directions and vibration from 5 to 150 Hz.

Accuracy specifications vary by input type, including values such as 0.03% of rdg + 30μV for specific voltage ranges and temperature accuracies ranging from 0.2°C to 6.1°C depending on the sensor family and range selected. Response times are configurable with options listed at 400 msec, 200 msec, 100 msec, 600 msec, 250 msec, 1000 msec, or 500 msec.

Measurement Ranges

  • Voltage/Current: ± 2.5 mADC to ± 250 mVDC; ± 2.0 VDC to ± 100 VDC and ± 200 VDC.
  • Temperature (Thermocouple): -200 to 400°C, -200 to 750°C, -200 to 760°C, -200 to 1250°C, 0 to 1768°C, and ranges up to 300 to 1820°C.
  • Temperature (RTD): Ranges include -200 to 1300°C, 0 to 2315°C, -200 to 850°C, and specific spans such as -80 to 259°C.
  • Digital Count: -199,999 to 999,999 or -199,999,999 to 999,999,999 depending on configuration.

Configuration Options

The DP63100 series supports a wide envelope of configurable options via plug-in cards. The base unit includes high compression cage-clamp terminal blocks for electrical connections and accepts power from 50 to 250 VAC (50/60 Hz, 14 VA) or 21.6 to 250 VDC (8 W). Excitation voltage is provided at +18 VDC ±5% @ 50 mA max.

Communication Options

Serial communication cards enable connectivity via RS232 or RS485 protocols, supporting RLC Protocol (ASCII), Modbus RTU, and Modbus ASCII. Available configurations include:

  • LDP6-CDC10: RS485 Serial (Terminal)
  • LDP6-CDC1C: RS485 Serial (Connector)
  • LDP6-CDC20: RS232 Serial (Terminal)
  • LDP6-CDC2C: RS232 Serial (Connector)

Setpoint and Output Cards

The series offers up to four setpoint outputs through various relay and transistor cards:

  • Dual Relay Card (LDP6-CDS10): Two FORM-C relays, Normally open & closed.
  • Quad Relay Card (LDP6-CDS20): Four FORM-A relays, Normally open only.
  • Sinking Open Collector (LDP6-CDS30): Isolated quad sinking NPN transistors.
  • Sourcing Open Collector (LDP6-CDS40): Isolated quad sourcing PNP transistors.
  • Analog Output Card (LDP6-CDL10): Retransmitted linear DC output of 0 to 20 mA, 4 to 20 mA, or 0 to 10 VDC with programmable scaling and reverse slope capability.

Mechanical Specifications

The meter measures 3.80 in (96.52 mm) wide by 1.95 in (49.53 mm) high, requiring a panel cut-out of 3.60 in (91.44 mm) width and 1.75 in (44.45 mm) height. The depth is 0.10 in (2.54 mm), with a recommended minimum clearance behind the panel of 2.1" (53.4) H x 5.5" (140) W.

Key Product Differences

The DP63100 series is distinguished by its modular architecture, allowing selection between terminal or connector-based serial communication and various relay configurations based on load requirements. The analog output card supports self-powered operation with a 50 V working voltage and isolation of 500 Vrms for 1 min to sensor commons. Relay cards offer varying contact ratings: the Dual Relay Card provides up to 5 amps @ 120/240 VAC, while the Quad Relay Card offers 3 amps per relay with a total current limit of 4 amps when all four are energized.

Approvals and certifications include CE, ISO 9001 Certified, ISO 9002 Certified, IEC 61010-1, EN 61010-1, IEC 529, EN 61326:2006, and a suite of EMC standards including EN 61000-4-2 through EN 61000-4-11 and EN 55011 Class A.

Accessories

accessoires

signal conditioners

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 28ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration