Need assistance? Call us: 1-800-663-4209
Series-32DZ
1/32 DIN Dual Zone Temp Controller, 5 Thermocouple Inputs, Fuzzy Logic
- Large Dual Display
- Independent Self-Tune for Each Zone
- Independent Fuzzy Logic for Each Zone
- Loop Break Protection
- Peak/Valley Indication
- Illuminated Keypad
- Four Password Protected Security Levels
Series-32DZ
From
C$
922.81
Product Overview
- Accuracy ± 0.25% span ± 1 least significant digit
- Control Output AC SSR Relay
- Display Note Two 4-digit, 7 segment, 0.25" high (6.35 mm) LEDs
- Display Type LED
- Enclosure Ratings IP66, NEMA Type 4X
- Memory Backup Non-Volatile
- Mounting Orientation 1/32 DIN
- Number of Digits 4
- Operating Temperature, Max 131 °F
- Operating Temperature, Min 14 °F
- Output Type (B) N/A
- Power Consumption max 5 VA
- Series ID Series-32DZ
- Supply Power Note 100 to 240 VAC, nominal, +10 - 15%, 50 to 400 Hz single phase; 132 to 240 VDC, nominal, +10 - 20%
- Supply Power Type AC/DC
- Supply Voltage 100 to 240 Vac, 132 to 240 Vdc
- Weight 4 oz
Supported Applications
The Dwyer Series-32DZ is a 1/32 DIN dual zone microprocessor-based temperature and process controller. Designed for compact panel installations, the series manages two independent control zones using fuzzy logic algorithms to regulate thermal or electrical processes.
- Dual-zone temperature regulation
- Process control applications requiring simultaneous monitoring of two inputs
Operating Conditions & Performance
The Series-32DZ accommodates a wide range of measurement technologies across its dual input channels. The documented measurement envelope spans -328 to 2372 °F (-200 to 1300 °C). Input configurations support Thermocouple types J, K, E, L, N; T, R, S, B, C; 1000 Ohm RTD; Current (0 or 4 to 20 mA); and Voltage (0 or 2 to 10 V).
Physical dimensions for the instrument are 25.4 mm (1.00 in) width by 45.6 mm (1.772 in) height with a depth of 20.5 mm (0.807 in). The unit features an IP66, UL type 4 enclosure rating when installed per spacing requirements to maintain panel structural integrity.
Input and Output Specifications
- Inputs: Configurable for Thermocouple J/K/E/L/N or T/R/S/B/C; 1000 Ohm RTD; Current (0/4-20 mA); Voltage (0/2-10 V).
- Outputs A & B: SSR, Switched Voltage 5 Vdc, Relay, Proportional current, or DC SSR.
Safety and Wiring Constraints
The instrument inputs are not isolated from each other; input sources must be isolated. Thermocouples must be of the isolated junction type, and process inputs may not share a common external ground. Signal (Class 2) wiring must not run in the same conduit or chase as power wiring to prevent erratic operation or circuit damage.
Configuration Options
The Series-32DZ is configured via a model number guide: 32DZ - <Input 1> - <Input 2> - <Output A> - <Output B> - <Options>. The series supports the following configurable elements:
Sensor Inputs
- Code 1: Thermocouple J, K, E, L, N
- Code 2: Thermocouple T, R, S, B, C
- Code 4: 1000 Ohm RTD
- Code 5: Current (0 or 4 to 20 mA)
- Code 6: Voltage (0 or 2 to 10 V)
Output Signals
Both Output A and Output B can be selected from the following types:
- SSR (Solid State Relay)
- Switched Voltage 5 Vdc
- Relay
- Proportional current
- DC SSR
Options and Accessories
- Option 992: RS-485 Serial Communications, allowing a remote computer to read and write all control parameters.
- Option 9502: 12 - 24 Vdc/Vac 50-400Hz power supply for low voltage equipment operation.
Electrical Connections
The controller utilizes compression type terminals. For relay output devices operating contactors or solenoids, the series supports snubber protection (P/N 541-0014) to suppress electrical noise and reduce arcing across contacts.
Key Product Differences
Variants within the Series-32DZ differ by their specific input sensor types, output signal configurations, and optional communication or power supply features. The model number structure explicitly defines these distinctions:
- Input 1 & Input 2 Codes: Define whether each zone accepts thermocouples (J/K/E/L/N vs T/R/S/B/C), RTD, current, or voltage signals.
- Output A & Output B Codes: Determine the actuation method for each control loop (e.g., Relay vs. SSR).
The series does not include a standard power supply in all configurations; Option 9502 is required to provide the 12 - 24 Vdc/Vac 50-400Hz input. Similarly, RS-485 communication capability is available only with Option 992.
Software & Drivers
Show Ratings & Reviews