Need assistance? Call us: 1-800-663-4209
FTB790-Series
Rate & Total Turbine Flow Meters w/ Intrinsically Safe Display
Compteurs de débit de turbine à évaluation et totalisation avec affichage intrinsèquement sûr
Models In Stock
- Both Rate and Total Indication
- Percent Reading Accuracy
- 6-Digit Display
- FM Approved (Standard unit only)
FTB790-Series
From
C$
1 571.54
Models In Stock
Product Overview
- Approvals CE,FM, ATEX
- Calibration Note Gallons Per Minute (Gallons Default)
- Display Type LCD
- Enclosure Ratings IP65, NEMA Type 4
- Materials 316 Stainless Steel
- Operating Pressure, Max 1500 psi
- Operating Temperature, Max 54 °C
- Operating Temperature, Min -18 °C
- Process Connection Type NPT Female
- Repeatability ±0.1%
- Series ID FTB790-Series
- Volumetric Flow Rate, Min 10 GPM
Les débitmètres à turbine à sécurité intrinsèque de la série FTB790, équipés d'un système électronique à microprocesseur, constituent des appareils de mesure de fluides durables, compacts et très précis, avec indication du total et du débit. Les informations sont clairement affichées sur un grand écran à cristaux liquides à 6 chiffres avec seulement 2 décimales flottantes pour les totaux de 0,01 à 999 999. Le fonctionnement s'effectue facilement à l'aide de seulement 2 boutons.
L'unité de base et l'écran sont alimentés par 2 piles alcalines AAA, offrant jusqu'à 2 ans d'utilisation. Le total cumulé, le total par lot et le débit sont des fonctions standard. Une courbe d'étalonnage à point unique peut être enregistrée dans la mémoire.
PDFs & Manuals
Accessories
meters/controllers
Show Ratings & Reviews
What is this products lifecycle?
Thank you for your inquiry. Other than the life span of the battery, when maintained, the inline flow meter will have a life span measured in years, approximately 5 ~ 8 years.
Date published: 2024-08-16
Can this meter be used with MIL-H-5606 hydraulic oil?
Thank you for your inquiry. This flow meter is designed for thin fluids < 100 cP
Date published: 2023-05-16
Will this meter work in the ranges of 2 liters per min to 6 liters per min?
Unfortunately no. The minimum flow rate that this flowmeter will measure accurately is 3.8 LPM.
Date published: 2023-08-25
What are the allowable mounting orientations? Vertical / flow up, vertical / flow down, horizontal?
Thank you for your inquiry about the inline flow meter. The orientation can be mounted in any position, yet, in a vertical position, the flow must go from floor to ceiling and must be full of flow at all times.
Date published: 2022-02-22
can these be utilized with nozzles?
The FTB791 requires a laminar flow in order to work properly. You cannot mount this sensor right before a nozzle. This sensor needs a straight pipe before and after the sensor. The FTB791 needs at least 15 inches of straight pipe before and 10 inches after the sensor. Please contact our Tech Support or flow@omega.com so we can fully understand your application to further advise as you need. Thank you!
Date published: 2019-05-20
Can you change the display unit from gallons to liters?
Thank you for your inquiry. The inline flow meter will have to be ordered to have the display read in LPM.
Date published: 2024-06-18
Do you use any lubricant in assembly?
Thank you for your inquiry. Lubrication is not used in the assembly for the FTB790 series.
Date published: 2020-04-23
can this flow meter be used with Methylene Chloride VDG?
Thank you for your question?
Here is the the whetted materials of our meters. Please see below: Housing: 316 SS
Journal Bearings: Ceramic (96% alumina)
Shaft: Tungsten carbide
Rotor and Supports: PVDF
Retaining Rings: 316 SS
Date published: 2019-07-01
en-US
fr
Save Configuration