Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | International +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FV500C-Series

Item# FV500C-Series

In Stock

Lead Time (If not in stock): 0 week

Product Specs

<< See all Product Models
Brand
Accuracy ± 0.75 %
Accuracy Detail ±0.75% of Reading (Liquid) (±0.5% of Reading: Typical Accuracy/ Non-Guaranteed) ±1% of Reading (Gas, Steam)
Data Interface BRAIN Communication
Data Interface Note Communication Signal: BRAIN or HART communication signal (superimposed on a 4 to 20 mA DC signal) Note: HART is a registered trademark of the HART Communication Foundation. Conditions of Communication Line: Load Resistance:250 to 600 Ω(including cable resistance). Supply Voltage:16.4 to 42 V DC for digital communications BRAIN and HART protocols. (16.4 to 30 V DC for intrinsically safe type). BRAIN: Space from other Power Line: 15cm or more (Parallel wiring should be avoided.) Communication Distance: Up to 2 km,when polyethylene insulated PVC- sheathed cables (CEV cables) are used. Communication distance varies depending on type of cable used and wiring. Load Capacitance: 0.22 µF or less Load Inductance: 3.3 mH or less Input Impedance Communicating Device: 10 kΩ or more at 2.4 kHz.
Electrical Connection Note In case of /FF1 or /CF1, CF11, /KF2, /KS2, /SF2, /SS2 the screw length is deeper than ANSI standard for 0.5 to 2 threads.
Electrical Output 4 to 20 mA, Two 125 mA SPST SSR
Enclosure Material N/A
Enclosure Ratings IP67 Type 4X (IEC 60529)
Measurement Pressure Type Gauge
Media Compatibility Clean dry air / inert gas, Liquids, Steam
Operating Pressure, Max 412 psi
Operating Temperature, Max 250 °C
Operating Temperature, Min -29 °C
Output Detail Pulse output,alarm output and status output use the common terminal, therefore these functions are not used simultaneously. Output Signal (◇): Dual Output (Both Analog and Transistor contact output can be obtained simultaneously). In this case refer to the item “Remarks on installation” for power supply and pulse output wiring. Analog: 4 to 20 mA DC, 2-wire system. Transistor Contact Output*: Open collector, 3-wire system. Pulse,alarm,status output are selected by parameter setting. Contact rating: 10.5 to 30 V DC, 120 mA DC*1 Low level: 0 to 2 V DC. *1: 10.5 to 30 V DC. 80 mA DC for ATEX Intrinsically Safe Approval (/KS2) and IECEx Intrinsically Safe Approval (/SS2)
Process Connection Type ANSI Flange
Repeatability ±0.2%
Supply Power 10.5 to 42 Vdc
Volumetric Flow Rate, Max 26 GPM
See All Specs Show Less