Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here
OM-CP-VOLT101A-Series
Voltage Data Loggers, Part of the NOMAD® Family
- 4 Hz Reading Rate
- Multiple Start/Stop Function
- Programmable Engineering Units
- Large Data Storage 1,000,000 Readings
OM-CP-VOLT101A-Series
From
€
260,04
Product Overview
- Accuracy Detail Nominal range @ 25°C
- Alarm User selectable high and low limits; blinking LED for alarm and low battery
- Baud Rate 115200
- Calibration Note Digital calibration through software, automatically recorded within device
- Conversion Time 133 ms
- Current Measurement Range N/A
- Data Interface USB
- Electrical Connection Removable Screw Terminal
- Frequency Rejection 50 to 60 Hz
- Height 1.4 in
- Housing Depth 1.5 in
- Housing Height 2.9 in
- Housing Width 5.8 in
- LED Functionality Green LED Blinks: 10 second rate to indicate logging 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory
- Length 0.6 in
- Materials Aluminum, ABS
- Measurement Type Voltage
- Memory 1,000,000 readings
- Memory Modes Yes
- Memory Note 1,000,000 readings; software configurable memory wrap 333,000 readings in multiple start/ stop mode
- Number of Channels 1
- Operating Temperature, Max 80 °C
- Operating Temperature, Min -40 °C
- Programmable Functions Security
- Real Time Recording May be used with PC to monitor and record data in real time
- Relative Humidity 0 to 95% RH
- Series ID OM-CP-VOLT101A-Series
- Software WIN XP SP3/VISTA/7 and 8
- Start Modes Button Push, Delayed Start, Immediate Start
- Supply Power 3.6 V Lithium Battery
- Supply Power Note 10 Years typical at a 15 Minute Reading Rate
- Supply Power Type Battery
- Time Accuracy ±1 minute/month (at 20ºC, stand alone logging)
- Weight 24 g
- Width 2.2 in
Supported Applications
The Omega OM-CP-VOLT101A Series, part of the NOMAD® Family, provides a low-cost solution for adding recording capability to existing measurement systems. These voltage data loggers are designed for measuring battery voltages, sensor outputs, photovoltaic studies, and other low-level DC sources.
Operating Conditions & Performance
The series features high accuracy with 16-bit resolution and programmable engineering units for low-level DC voltage recording. Operating ambient temperature ranges from -40 to 80°C (-40 to 176°F) in environments up to 0 to 95% RH non-condensing. The enclosure is rated NEMA 4 (IP65). Response time is specified at 133 mS.
Performance specifications vary by input range as documented:
- ±160 mV Range: Resolution of 5 µV with calibrated accuracy of ±0.01% and differential input type.
- -3 to 3 Vdc Range: Resolution of 0.1 mV with calibrated accuracy of ±0.05% and single-ended input type.
- -8 to 24 Vdc Range: Resolution of 0.5 mV with calibrated accuracy of ±0.05% and single-ended input type.
- -8 to 32 Vdc Range: Resolution of 1.0 mV with calibrated accuracy of ±0.05% and single-ended input type.
Input impedance is >1 MΩ for the ±160 mV model and 125 kΩ for the -3 to 3 Vdc, -8 to 24 Vdc, and -8 to 32 Vdc models. Overload protection ratings are ±5V (for 10 seconds) on the ±160 mV range and ±50V indefinitely on the other ranges.
Configuration Options
The OM-CP-VOLT101A Series is available in four primary input configurations. The housing material is ABS Plastic, with overall dimensions of 36 H x 64 W x 16 mm D (1.4 x 2.5 x 0.6"). Weight is 24 g (0.9 oz). Electrical connections utilize a removable screw terminal.
Power is supplied by an included, user-replaceable 3.6V lithium battery. Data recording and analysis require the OM-CP-IFC200 Windows software and USB interface cable, which are sold separately or as part of specific accessory bundles. The series supports optional NIST calibration certificates.
Available options and accessories include:
- OM-CP-BAT105: Replacement 3.6V lithium battery
- OM-CP-WATERBOX101A: Weatherproof NEMA 4 (IP65) enclosure for the data logger
- Replacement Terminal Blocks: OM-CP-CONNECTOR-2 (2 position, compatible with -3 to 3 Vdc, -8 to 24 Vdc, and -8 to 32 Vdc models) and OM-CP-CONNECTOR-3 (3 position, for the ±160 mV model)
Key Product Differences
Variants within the series are distinguished by their voltage input range, resolution, accuracy class, and input type. Models ending in "-CERT" include a NIST calibration certificate.
- OM-CP-VOLT101A-160MV: ±160 mV range, 5 µV resolution, differential input.
- OM-CP-VOLT101A-2.5V: -3 to 3 Vdc range, 0.1 mV resolution, single-ended input.
- OM-CP-VOLT101A-15V: -8 to 24 Vdc range, 0.5 mV resolution, single-ended input.
- OM-CP-VOLT101A-30V: -8 to 32 Vdc range, 1.0 mV resolution, single-ended input.
PDFs & Manuals
Software & Drivers