FTB4000-Series
From
€
188,45
Product Overview
- Accuracy ± 1.5 %
- Accuracy Detail From 10% of continuous to maximum flow: ±1.5% of reading; below 10% of continuous flow: ±2% of reading
- Approvals CE
- Display Mechanical Counter
- Height 3.03 in
- Installation 10 pipe diameters upstream, 5 downstream
- Length 5.12 in
- Materials, Wetted Brass, EDPM, Polyimide, Polypropylene, Sapphire, Stainless Steel
- Media Compatibility Liquids
- Operating Pressure, Max 150 psi
- Operating Temperature, Max 90 °C
- Pressure Drop, Max 3.6 psi
- Process Connection Type NPT Male
- Series ID FTB4000-Series
- Supply Voltage 24 Vac/Vdc
- Volumetric Flow Rate, Min 0.22 GPM
- Weight 0.6 kg
- Width 2.75 in
Supported Applications
The Omega FTB4000-Series consists of turbine flow meters designed for water totalization, specifically targeting water billing applications. These instruments feature tamper-resistant, non-resettable totalizers with large faces intended to be easy to read.
Operating Conditions & Performance
The series measures hot or cold water within a maximum process temperature of 90°C (200°F) and a pressure rating of 150 psi. Accuracy is specified as ±1.5% of reading from 10% of continuous flow to maximum flow, and ±2% of reading below 10% of continuous flow.
Flow rates across the series range from 0.13 GPM (minimum) up to 132 GPM (maximum). Installation requirements mandate 10 pipe diameters upstream and 5 downstream. Mounting orientation is size-dependent: horizontal mounting is required for 1, 1¼, and 1½" models, while vertical mounting applies only to ½ and ¾" sizes.
Configuration Options
The FTB4000-Series offers configurable options including built-in strainers, trickle flow indication, locking nuts, and coupling pieces. Models are available with or without a reed relay scaled pulse output for remote totalization; the pulse output option is factory installed and must be requested at order time.
Key configuration parameters include:
- Pulse Output Option (Suffix 'P'): Provides 1 gal/pulse with 1.8 m (6') of cable included, powered by a 6 to 16 Vdc supply.
- Totalizer Capacity: Maximum reading is 10 million gallons for ½ and ¾" models; 100 million gallons for 1, 1¼, and 1½" models.
- Process Connections: MNPT connections are provided for ½ to 1½" models. The 2" model utilizes an ANSI 150# Flange connection.
Wetted parts consist of a brass body, stainless steel polyimide (fiberglass), polypropylene, and EPDM O-rings. All units carry CE approval and include a complete operator's manual with a 1 YEAR WARRANTY.
Key Product Differences
The series is distinguished by size-specific flow ranges and connection types:
- ½" Models (FTB-4105A): Flow range of 0.13 to 13 GPM with MNPT connections.
- ¾" Models (FTB-4107A): Flow range of 0.22 to 20 GPM with MNPT connections.
- 1" and 1¼" Models (FTB-4110A, FTB-4112A): Both sizes share a flow range of 0.5 to 50.0 GPM with respective MNPT connections.
- 1½" Model (FTB-4115A): Flow range of 0.8 to 90.0 GPM with MNPT connection.
- 2" Model (FTB-4120A): Flow range of 1.3 to 132.0 GPM with ANSI 150# Flange connection and a maximum temperature rating of 90°C (194°F).