Brand
Accuracy ± 0.05 %
Accuracy Detail Voltage and Current: ±0.05%, Thermoocouple: (J, K, T, E): ±1˚C, (N, L, U, P, W5, W3, LR, A1, A2, A3, M, E, B, R): ±2˚C, RTD: ±0.4˚C (CU10: ±1.0˚C)
Altitude,Max 2000 m
Burnout Current 10 µA
CMRR 120 dB
Configuration ARM Cortex-A8, 1 GHz
Connection Note 2 Ports (One front, One back)
Data Interface Ethernet, Modbus
Depth Behind Panel 171 mm
Dielectric Strength 2300 Vac, 50/60 Hz for 1 minute between power terminal and earth
Display Type LCD
Enclosure Ratings IP20, IP65
Features 19 languages including English, Japanese, Chinese (simplified, traditional), French, German, Spanish, Swedish, Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese, Brazil Portuguese and Czech
Input Current ± 26 mA
Input Note Sensor Lead Resistance Effect: Thermocouple: 0.32 ppm of reading/Ω, 3-Wire RTD: 2.6˚C/Ω of resistance difference of two leads (based on ˚C measurement temperature for Pt100), 2-Wire RTD: 2.6˚C/Ω of resistance sum of two leads (based on ˚C measurement temperature for Pt100); RTD Input: ±20V, Thermocouple and Voltage Input: ±65V, Current (mA) Input: ±10V
Input Type Thermocouple, RTD, Voltage, Current
Input Voltage ± 60 mVdc, ± 200 mVdc, ± 1 Vdc, ± 2 Vdc, ± 6 Vdc, ± 20 Vdc, ± 50 Vdc, 0.4 to 2 Vdc, 1 to 5 Vdc
Insulation Resistance 20 MΩ @ 500 Vdc
Isolation 1500 Vac at 50/60 Hz for 1 minute
Keypad Functions Start/Stop Recording and turn off Display only (for quick re-start), Does not turn off Power to the unit
Length 189 mm
Measurement Type Universal
Memory 256 MB Samples on 128 MB Flash Card
NMRR 55 dB
Operating Temperature, Max 50 °C
Operating Temperature, Min 0 °C
RTD Type 2-, 3- or 4-wire RTD
Relative Humidity 20 to 90% RH
Relative Humidity Note 20 to 90% RH (noncondensing), maximum relative humidity of 90% RH is for ambient temperature up to 38˚C (100˚F) decreasing linearly to 50% RH at 50˚C
Sampling Rate 10 Hz (10 updates/second)
Sensor Break Detection Sensor opened for thermocouple, RTD and mV inputs; below 1 mA for 4 to 20 mA input, below 0.25V for 1 to 5V inputs, unavailable for other inputs; Within 1 second for thermocouple, RTD and mV inputs; 0.1 second for 4 to 20 mA and 1 to 5V inputs
Series ID RD1000-RD2000-RD3000-Series
Shock Resistance 30m/s² (3g) for Operation, 20 g for Transportation
Software Standard Software supplied for Historical data viewing and Configuration, Optional: Data Acquisition Studio Software, OS:Windows XP/Vista/7/8
Storage Temperature, Max 70 °C
Storage Temperature, Min -30 °C
Supply Power Note 90 to 250 Vac, 47 to 63 Hz,52 VA, 26 W max; 11 to 36 Vdc, 26 VA, 26 W max (optional)
Supply Power Type AC
Supply Voltage 90 to 250 Vac
Thermal Effects ±0.1 µV ±15 ppm of reading for all inputs except mA, ±30 ppm of reading for mA input
Thermocouple Type J, K, T, E, N, R, S, B, C, W5, W3, L, U, P, A1, A2, A3, M, LR
Vibration Resistance 10 to 55 Hz, 10 m/s² for 2 hours