Netherlands 07077 03815 | International +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here
RD1000-RD2000-RD3000-Series
Added to Your Shopping Basket
Configuration complete.
Please add to basket to keep it or exit the configuration
Please add to basket to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product Models| Brand |
|
| Accuracy | ± 0.05 % |
| Accuracy Detail | Voltage and Current: ±0.05%, Thermoocouple: (J, K, T, E): ±1˚C, (N, L, U, P, W5, W3, LR, A1, A2, A3, M, E, B, R): ±2˚C, RTD: ±0.4˚C (CU10: ±1.0˚C) |
| Altitude,Max | 2000 m |
| Burnout Current | 10 µA |
| CMRR | 120 dB |
| Configuration | ARM Cortex-A8, 1 GHz |
| Connection Note | 2 Ports (One front, One back) |
| Data Interface | Ethernet, Modbus |
| Depth Behind Panel | 171 mm |
| Dielectric Strength | 2300 Vac, 50/60 Hz for 1 minute between power terminal and earth |
| Display Type | LCD |
| Enclosure Ratings | IP20, IP65 |
| Features | 19 languages including English, Japanese, Chinese (simplified, traditional), French, German, Spanish, Swedish, Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese, Brazil Portuguese and Czech |
| Input Current | ± 26 mA |
| Input Note | Sensor Lead Resistance Effect: Thermocouple: 0.32 ppm of reading/Ω, 3-Wire RTD: 2.6˚C/Ω of resistance difference of two leads (based on ˚C measurement temperature for Pt100), 2-Wire RTD: 2.6˚C/Ω of resistance sum of two leads (based on ˚C measurement temperature for Pt100); RTD Input: ±20V, Thermocouple and Voltage Input: ±65V, Current (mA) Input: ±10V |
| Input Type | Thermocouple, RTD, Voltage, Current |
| Input Voltage | ± 60 mVdc, ± 200 mVdc, ± 1 Vdc, ± 2 Vdc, ± 6 Vdc, ± 20 Vdc, ± 50 Vdc, 0.4 to 2 Vdc, 1 to 5 Vdc |
| Insulation Resistance | 20 MΩ @ 500 Vdc |
| Isolation | 1500 Vac at 50/60 Hz for 1 minute |
| Keypad Functions | Start/Stop Recording and turn off Display only (for quick re-start), Does not turn off Power to the unit |
| Length | 189 mm |
| Measurement Type | Universal |
| Memory | 256 MB Samples on 128 MB Flash Card |
| NMRR | 55 dB |
| Operating Temperature, Max | 50 °C |
| Operating Temperature, Min | 0 °C |
| RTD Type | 2-, 3- or 4-wire RTD |
| Relative Humidity | 20 to 90% RH |
| Relative Humidity Note | 20 to 90% RH (noncondensing), maximum relative humidity of 90% RH is for ambient temperature up to 38˚C (100˚F) decreasing linearly to 50% RH at 50˚C |
| Sampling Rate | 10 Hz (10 updates/second) |
| Sensor Break Detection | Sensor opened for thermocouple, RTD and mV inputs; below 1 mA for 4 to 20 mA input, below 0.25V for 1 to 5V inputs, unavailable for other inputs; Within 1 second for thermocouple, RTD and mV inputs; 0.1 second for 4 to 20 mA and 1 to 5V inputs |
| Series ID | RD1000-RD2000-RD3000-Series |
| Shock Resistance | 30m/s² (3g) for Operation, 20 g for Transportation |
| Software | Standard Software supplied for Historical data viewing and Configuration, Optional: Data Acquisition Studio Software, OS:Windows XP/Vista/7/8 |
| Storage Temperature, Max | 70 °C |
| Storage Temperature, Min | -30 °C |
| Supply Power Note | 90 to 250 Vac, 47 to 63 Hz,52 VA, 26 W max; 11 to 36 Vdc, 26 VA, 26 W max (optional) |
| Supply Power Type | AC |
| Supply Voltage | 90 to 250 Vac |
| Thermal Effects | ±0.1 µV ±15 ppm of reading for all inputs except mA, ±30 ppm of reading for mA input |
| Thermocouple Type | J, K, T, E, N, R, S, B, C, W5, W3, L, U, P, A1, A2, A3, M, LR |
| Vibration Resistance | 10 to 55 Hz, 10 m/s² for 2 hours |
| See All Specs | |
PDFs & Manuals