Netherlands 07077 03815 | International +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here
SCR19-H
SCR Power Controllers or Electrical Resistance Heaters 250 A Max
- Zero Crossing or Phase-Angle Fired
- Diagnostic LED Indicators
- Single- or 3-Phase Load Switching
- Extends Heater Life -- Reduces Thermal Shock
Product Overview
- Cooling Fan cooled, requires 120 Vac control voltage
- Device Load Resistive
- Display and Indications Open SCR, Shorted
- Frequency 50 to 60 Hz
- Input Control Signal 4 to 20 mA
- Isolation 2500 Vac
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Over-Voltage Protection Inherent built-in immunity
- Series ID SCR19-H
The SCR19-H and SCR39-H Series power controllers are designed to proportion electric power to resistive loads only, such as ovens, furnaces, heat sealers, etc. The controllers consist of power semi-conductors (SCRs), properly sized heat sinks, trigger circuitry, and fuses supplied on panels for surface mounting. (Note: They are not designed to drive transformers or any inductive load.) The power controller accepts a 4 to 20 mAdc output from a temperature controller.
Zero Voltage Switched Models
The SCR19Z-H and SCR39Z-H SCR power controllers are zero crossover fired, high-power solid state switched devices. Zero crossover firing eliminates the RFI generation associated with mechanical relays. With zero crossover firing, the output appears as bursts of full sine waves of line voltage which provides excellent regulation to the load.
Phase Angle Fired Models
The SCR19P-H and SCR39P-H SCR phase-angle fired power controllers turn on each SCR for a controlled portion of a half-cycle of the line voltage. The effective line voltage is determined by the portion of the line voltage delivered, which is proportional to the input control signal. Additionally, the voltage is regulated as the line voltage changes.
Zero Voltage Switched Models
The SCR19Z-H and SCR39Z-H SCR power controllers are zero crossover fired, high-power solid state switched devices. Zero crossover firing eliminates the RFI generation associated with mechanical relays. With zero crossover firing, the output appears as bursts of full sine waves of line voltage which provides excellent regulation to the load.
Phase Angle Fired Models
The SCR19P-H and SCR39P-H SCR phase-angle fired power controllers turn on each SCR for a controlled portion of a half-cycle of the line voltage. The effective line voltage is determined by the portion of the line voltage delivered, which is proportional to the input control signal. Additionally, the voltage is regulated as the line voltage changes.
PDFs & Manuals