Regulated/Adjustable Power Supply for Transducers and Bridges
- Adjustable 4 to 15 Vdc Output
- Up to 150 mA Current
- Well Suited for 120 ½ and 350 ½ Strain Gages
- Can Power Multiple Pressure Transducers or Load Cells
PST-4130-P-S--for-Bridges
From
Product Overview
- Frequency Input Range 50 to 60 Hz
- Isolated Analog Voltage 1500 Vdc
- Line and Load Regulation 0.0001
- Noise 0.5 mVrms
- Operating Temperature, Max 70 °C
- Operating Temperature, Min 0 °C
- Series ID PST-4130-P-S--for-Bridges
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -25 °C
- Supply Power Note 115 Vac ±10% 50 to 60 Hz
- Temperature Coefficient 50 ppm/°C
- Weight 510 g
Supported Applications
The Omega PST-4130 is an AC line-powered adjustable output power source designed for strain gages and pressure transducers. It can also be used as a high-quality voltage source or reference in many applications.
Operating Conditions & Performance
The unit provides an adjustable output of 4 to 15 Vdc with a maximum current of 150 mA (see graph). Line and load regulation is specified at 0.005%, with noise levels of 0.5 mV RMS and stability of 50 ppm/°C. The PST-4130 features excellent regulation, stability, and very low noise.
Operating temperature ranges from 32 ° to 158 °F (0 ° to 70 °C), while storage temperature is rated for -13 to 185 °F (-25 ° to 85 °C). The device includes a split bobbin transformer providing 1500 Vdc line isolation and utilizes remote sensing to eliminate line drop errors.
Configuration Options
The PST-4130 series is configured with the following electrical and physical characteristics:
- Input Power: 115 Vac ±10%, 50-60 Hz.
- Output Voltage: Adjustable 4 to 15 Vdc via B+ ADJUST potentiometer (Diameter: 0.32" TYP).
- Terminals: Terminals 1-7 with jumpers required between terminals 1 & 2 and terminals 3 & 4.
- Sensing Configuration: Corresponding sense leads must be connected to their corresponding excitation leads either at the sensor or power source for the unit to function correctly.
The enclosure dimensions are 3.75" length, 2.00" width, and 2.87" height (with a depth of 2.25"). The total weight is 18 oz. (510 g).
Key Product Differences
The PST-4130 model number guide identifies this specific configuration as the regulated/adjustable power supply for transducers and bridges. Safety operation at low voltage settings requires an external resistor in the B+ line to take most of the drop externally, with the + sense line connected in the normal manner; prolonged shorts across the output should be avoided.