Skip to search Skip to main content Skip to navigation

Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FTB790-Series

Rate and Total Turbine Flow Meters with Intrinsically Safe Display

  • Both Rate and Total Indication
  • Percent Reading Accuracy
  • 6-Digit Display
  • FM Approved (Standard unit only)
FTB790-Series
From  991,03
Rate and Total Turbine Flow Meters with Intrinsically Safe Display FTB790-Series FTB790-Series
loading all models
Product Overview
  • Approvals CE,FM, ATEX
  • Calibration Note Gallons Per Minute (Gallons Default)
  • Certifications NIST Traceable Calibration
  • Display Type LCD
  • Enclosure Ratings IP65, NEMA Type 4
  • Materials 316 Stainless Steel
  • Materials, Wetted 316 Stainless Steel, Alumina Ceramic, FKM, PVDF, Tungsten Carbide
  • Media Compatibility Liquids
  • Operating Pressure, Max 1500 psi
  • Operating Temperature, Max 54 °C
  • Operating Temperature, Min -18 °C
  • Process Connection Type NPT Female
  • Repeatability ±0.1%
  • Series ID FTB790-Series
  • Volumetric Flow Rate, Min 10 GPM

Supported Applications

The Omega FTB790 Series consists of FLOMEC® G2 Industrial Grade turbine flow meters designed for liquid flow measurement. The series is engineered to monitor clean fluids, plant process water, chemical feed lines, and industrial fluids including plating solutions, ammonium, fuel products, sulfuric acid, bleach, batching blends, food and beverage processing streams, and water.

Operating Conditions & Performance

The FTB790 Series operates within a process temperature range of -40° F to 250° F (-40° C to 121° C) and an ambient temperature range of -20° F to 180° F (-28° C to 82° C). Storage temperatures are specified from 0° F to +129° F (-18° C to +54° C). The meters feature a modular design with IP65 enclosure ratings and utilize AAA Alkaline batteries providing an estimated life of 2 years.

Accuracy varies by model size and configuration. For turbine-only configurations, accuracy is ± 2.0% for the 1/2" (Model 05), ± 1.5% for Models 3/4" (07) and 1" (10), and ± 1.0% for Models 1-1/2" (15) and 2" (20). When equipped with onboard computer electronics, accuracy improves to ± 1.5% for Model 05, ± 1.0% for Models 07 and 10, and ± 0.75% for Models 15 and 20. Repeatability is specified as ± 0.1%, with PVDF models rated at ± 0.3%. The series supports flow rates ranging from 1 - 10 GPM (3.8 - 38 L/min) up to 20 - 200 GPM (76 - 760 L/min), depending on the model size.

Pressure ratings are material-dependent: Stainless Steel 316 SS housings support 1,500 psi (102 bar); Aluminum supports 300 psi (21 bar); and PVDF supports 100 psi (6.9 bar). ANSI Flange 316 SS pressure is governed by flange rules, while Sanitary Flange 316 SS limits depend on fitting, clamp size, and temperature.

Configuration Options

The series offers configurable housing materials including 316 Stainless Steel for water and chemical products, Aluminum for fuels and petroleum-based fluids, and PVDF (available in 1/2" and 1" sizes) for aggressive chemicals. Wetted components vary by material: Stainless Steel models feature a Tungsten Carbide shaft, 96% Alumina Oxide Ceramic bearings, and a PVDF rotor; PVDF housings include 98% Alumina Ceramic bearings/shafts and Fluorocarbon rings (optional PTFE).

Process connections are available in NPT or ISO (Female) BSPT (ISO 7 designation is RC). Additional fitting options include 150# ANSI Flange (available on S10, S15, and S20 only) and Tri-Clamp fittings (Stainless Steel models only; sizes range from Model 05 to 20). Note that the fitting size is one size larger than the meter size.

Electronic configurations include onboard computer electronics with a local display showing rate of flow calibrated in gallons or liters, along with two totals: Batch Total (resettable) and Total (non-resettable). The meters are field calibratable with non-volatile memory. Accessory modules allow signal export to other equipment.

Approvals include CE, ATEX, NEMA 4, FM APPROVED US, IEC, and IECEx for specific sensor configurations. Accessories such as the 120077-01 (FM Approved Sensor), 120077-02 (ATEX Approved Sensor), 90° Display Adaptor Kit, and Remote Kits are available.

Model Number Configuration

The model number follows the format: G2 - <TURBINE MATERIAL> - <TURBINE SIZE> - <FITTING TYPE> - <ELECTRONIC CHOICE> - <CALIBRATION OF COMPUTER / DISPLAY> - <PACKAGING>. Key codes include:

  • Turbine Material: S (Stainless Steel), A (Aluminum), P (PVDF for 1/2" and 1" only).
  • Turbine Size: 05 (½ in.), 07 (¾ in.), 10 (1 in.), 15 (1-½ in.), 20 (2 in.).
  • Fitting Type: N (NPT Female), I (ISO/BSPT Female), F (150# ANSI Flange for S10, S15, S20 only), T (Tri-Clamp).
  • Electronic Choice: Q9 (Q9 2-Button Computer), Q1 (Vertical Mount with 90° Adapter), XX (No Electronics - Turbine Only).

Filtration Requirements

To ensure accuracy, the series requires filtration based on model size. For Models ½ in., ¾ in., and 1 in., maximum particulate size is limited to 0.005 inches (125 µm / No. 120 Mesh). For Models 1-½ in. and 2 in., the limit is 0.018 inches (500 µm / No. 35 Mesh).

Key Product Differences

The FTB790 Series distinguishes itself through housing material selection tailored to fluid compatibility: Aluminum for fuels, Stainless Steel for general water and chemical applications, and PVDF for aggressive chemicals in smaller sizes (½" and 1"). Electronic options range from turbine-only units requiring external signal processing to fully integrated models with onboard Q9 or Q1 computers providing local rate and totalization displays. The series supports both standard threaded connections (NPT/ISO) and sanitary/flanged configurations, though ANSI flanges are restricted to larger stainless steel sizes (S10, S15, S20), while Tri-Clamp fittings are available across all stainless steel model sizes.

Accuracy performance is tiered by size and electronics; the ½" turbine-only unit offers ± 2.0% accuracy compared to ± 1.5% with onboard computer electronics, whereas larger models (1-½" and 2") achieve ± 1.0% without electronics and improve to ± 0.75% when equipped with computers.

en-SG
en_NL
Save Configuration