Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here
Oxygen-Sensor-M16-Thread
Oxygen Sensors – M16 Thread Aluminum (SO-D2-XXX-AXXXC) & Standard M16 Thread (SO-D0-XXX-AXXXC)
- Measurement ranges from 10ppm to 96% Oxygen
- High accuracy
- Ideal for In-Situ O2 measurement
- Stable Sensor characteristic across range
- Stable Sensor characteristics across range
- Sensor signal not affected by temperature
Oxygen-Sensor-M16-Thread
From
€
713,71
Product Overview
- Data Interface RS232
- Electrical Output 4 to 20 mA, 0 to 5 Vdc
- Output Signal Current, Voltage
- Process Connection Type Metric Male
- Sensor Type Zirconia
- Series ID Oxygen-Sensor-M16-Thread
- Supply Voltage 6 to 25 Vdc
- Target Gas Oxygen
Supported Applications
The M16 thread oxygen sensors use zirconium dioxide (ZrO2) technology to measure oxygen O2 concentration across a very wide span, from 10 ppm O2 - 1000 ppm O2 at the trace end up to 1.00 % O2 - 96.0 % O2 at the high end. This range makes a single sensor family suitable for medical, laboratory, and food applications where accurate oxygen measurement is required.
Because the sensor characteristics are stable and the signal shows minimal interference from other gases, the sensors are well matched to In-Situ O2 measurement with long service life and low drift using single-point calibration. The measuring principle is a limiting current zirconium dioxide sensor, and the output follows the characteristic Is(O2) = -k · ln(1 - [O2]/100), where the sensor current is expressed in µA and the oxygen concentration in %.
The sensors carry vibration resistance to the European Norm EN60068-2-6 (sinusoidal vibration tests), supporting installation in machinery and process environments. Operation outside the specified measuring range can cause permanent damage of the electrode, so the correct part number should be selected for the target concentration.
Operating Conditions & Performance
The process connection is M 16 * 1.5 mm. The sensors run from a supply of 6-25VDC, with a nominal 12VDC 0.5A, and use a sensor bias voltage of 0.7 to 1.6 volts. Cold resistance of the heater is R(25°C) = 3.25 Ω ± 0.25 Ω.
After a warm up time of Min. 30 s, the sensors deliver an output current that depends on the selected range: 150 µA - 250 µA on the lower-concentration ranges, 100 µA - 200 µA on the 0.10 % O2 - 25.0 % O2 range, and 15 µA - 30 µA on the 1.00 % O2 - 96.0 % O2 range.
The housing temperature during operation is rated to 70 °C, measured at an ambient temperature of 25°C. The maximum permissible operating temperature is 200 °C, limited by the cable assembly, and can also be limited by the use of an optional Teflon filter. Expected lifetime is an MTTF typical of 10 years.
Accuracy by range
- 10 ppm O2 - 1000 ppm O2: accuracy ± 20 ppm O2, reproducibility < 10 ppm O2
- 0.01 % O2 - 1.0 % O2: accuracy ± 100 ppm O2, reproducibility < 100 ppm O2
- 0.01 % O2 - 2.0 % O2: accuracy ± 200 ppm O2, reproducibility < 100 ppm O2
- 0.05 % O2 - 5.0 % O2: accuracy ± 500 ppm O2, reproducibility < 250 ppm O2
- 0.10 % O2 - 25.0 % O2: accuracy ± 0.25 % O2, reproducibility < 0.1 % O2
- 1.00 % O2 - 96.0 % O2: accuracy ± 1.00 % O2, reproducibility < 0.2 % O2
Configuration Options
The two housing families share the M 16 * 1.5 mm process connection but differ in construction and response.
The standard SO-D0-XXX-AXXXC uses a screw-mountable housing with a sintered metal top. It measures M 16 * 1.5 mm L tot.= 49 mm with a sintered metal top of Ø12 mm, L= 20 mm, SW22. Its response time (t90) is < 5 seconds, with a heating voltage of 4.1 volts and power consumption of 1.8 watts, both depending on application.
The aluminium SO-D2-XXX-AXXXC uses an aluminium-screw-mountable housing with a sintered metal filter, sized M 16 * 1.5 mm L tot.= 47.4 mm with a sintered metal filter of Ø12.5 mm, SW22. Its response time (t90) is < 25 seconds (depends upon gas exchange flow), with a heater voltage of 3.8 volts and power consumption of 1.6 watts, both depending on application. Both families connect through a Rast 2.5 plug and share the six-pin pinout.
Key Product Differences
Each family is offered in six measuring ranges, identified by the middle digits of the part number:
- SO-D0-001-AXXXC / SO-D2-001-AXXXC: 10 ppm O2 - 1000 ppm O2
- SO-D0-010-AXXXC / SO-D2-010-AXXXC: 0.01 % O2 - 1.0 % O2
- SO-D0-020-AXXXC / SO-D2-020-AXXXC: 0.01 % O2 - 2.0 % O2
- SO-D0-050-AXXXC / SO-D2-050-AXXXC: 0.05 % O2 - 5.0 % O2
- SO-D0-250-AXXXC / SO-D2-250-AXXXC: 0.10 % O2 - 25.0 % O2
- SO-D0-960-AXXXC / SO-D2-960-AXXXC: 1.00 % O2 - 96.0 % O2
Cable length is selected through the trailing part code. The SO-D0-xxx-A100C and SO-D2-xxx-A100C carry a 100 mm cable, while the SO-D0-xxx-A300C and SO-D2-xxx-A300C carry a 300 mm cable; both terminate in a Rast 2,5 plug connector. Optional accessories include digital I/O open collector outputs, a custom electronics board, and an optional electronics control board with industry standard outputs.