Netherlands 07077 03815 | International +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here
FMA-LP1606A
LOW PRESSURE DROP GAS MASS FlowMeters
Added to Your Shopping Basket
Configuration complete.
Please add to basket to keep it or exit the configuration
Please add to basket to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product Models| Brand |
|
| Accuracy | ± 0.8 %, ± 0.8 % |
| Accuracy Detail | ± (0.8% of rdg + 0.2% FS), ± (0.8% of rdg + 0.2% FS) |
| Additional Features 1 | Power Supply Included, Power Supply Included |
| Calibration | NIST 5-Point Certificate, NIST 5-Point Certificate |
| Data Interface | RS232, RS232 |
| Display Type | LCD, LCD |
| Electrical Connection | 8-pin mini DIN, 8-pin mini DIN |
| Electrical Output | 0 to 5 V |
| Enclosure Ratings | IP40, IP40 |
| GrossWeightValue | 2.13 |
| Height | 4.4 in, 4.4 in |
| Humidity Range | 0 to 100% RH non-condensing, 0 to 100% RH non-condensing |
| Length | 4 in, 4 in |
| Mass Reference Conditions | 25°C, 14.7 psia (STP), 25°C, 14.7 psia (STP) |
| Materials, Wetted | Aluminum, FKM, Nylon, Silicone, Stainless Steel, Aluminum, FKM, Nylon, Silicone, Stainless Steel |
| Measurable Flow Rate | 125%, 125% |
| Media Compatibility | Clean dry air / inert gas, HVAC / room air, Inert / non-reactive gases, Oxygen, Air, Gases, Nitrogen, Oxygen |
| Operating Pressure, Max | 50 psi, 50 psi |
| Operating Temperature, Max | 50 °C, 50 °C |
| Operating Temperature, Min | -10 °C, -10 °C |
| Output Signal | Voltage |
| Pressure Drop Note | 0.25 Pressure Drop at Max Flow (psid) Venting to Atmosphere, 0.25 Pressure Drop at Max Flow (psid) Venting to Atmosphere |
| Pressure Drop, Max | 0.25 psi, 0.25 psi |
| Process Connection Size | 1/8 in, 1/8 in |
| Process Connection Type | NPT Female, NPT Female |
| Repeatability | ± 0.2%, ± 0.2% |
| Response Time | 10 ms, 10 ms |
| Response Time Note | 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable via RS232 communications., 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable via RS232 communications. |
| Series ID | FMA-LP1600A-Series |
| Span Shift | 0.02% FS/°C/atm, 0.02% FS/°C/atm |
| Supply Current | 40 mA, 40 mA |
| Supply Power Note | 40 mA typical current draw; 100 mA available supply recommended, 40 mA typical current draw; 100 mA available supply recommended |
| Supply Voltage | 7 to 30 Vdc, 7 to 30 Vdc |
| Turndown Ratio | 200:1, 200:1 |
| Volumetric Flow Rate, Max | 5 SLM |
| Volumetric Flow Rate, Min | 0.025 SLM, 0.1 SLM |
| Width | 1.6 in, 1.6 in |
| Country of Origin | United States |
| See All Specs | |
PDFs & Manuals
Accessories
cables
installation hardware
NATURAL POLY THREAD ADPT 10/PK
€ 8,57 / each
0 In Stock