Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new site - found a bug? Please report it here
CL515-PLUS-series
High Accuracy RTD Auto-Connect Display Calibrator & Thermometer
- Easy to Use
- Calibrate and Measure Most RTD Sensors
- Comes Protected With a Rugged Rubber Boot
- Calibrate Directly in Temperature (ºC or ºF)
CL515-PLUS-series
From
€
2.352,20
Product Overview
- Accuracy ± 0.015 %
- Accuracy Detail ± (0.015% of reading + 0.05 Ω)
- Additional Features 1 Source Only
- Battery life 50 hr
- Display Type LCD
- Display Type Note High contrast graphic liquid crystal display, LED backlighting for use in low lit areas
- Height 41 mm
- Length 143 mm
- Operating Temperature, Min -25 °C
- Operating Temperature Note Nominal Temperature: 23°C
- Relative Humidity, Max 0.9
- Relative Humidity, Min 10%
- Relative Humidity Note 10% ≤RH ≤90% (0 to 35°C), non-condensing 10% ≤RH≤ 70% (35 to 60°C), non-condensing, Nominal Relative Humidity: 70%
- Supply Voltage 6 Vdc
- Temperature Drift ± 0.01%
- Temperature Drift Note ± 0.01% of span outside of 23°C ± 10°C (73°C ± 18°F)
- Thermocouple Type None
- Type of RTD Signal 100 Ω
- Voltage Read Excitation: Current 0.5 mA nominal Normal Mode Rejection: 50/60 Hz, 50 dB Common Mode Rejection: 50/60 Hz, 120 dB
- Voltage Source Accuracy: From 1 to 10.2 mA external excitation Current ± (0.015% of Reading + 0.05 Ω) Below: 1 mA of external excitation Current: ± (0.015% of reading + 0.025 mV/mA excitation current + 0.05 Ω) Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 Ω Allowable Excitation Current Range <41Ω: 10.2 mA maximum; steady or pulsed/intermittent 410 to 4001Ω: 1 mA maximum; steady or pulsed/intermittent Pulsed Excitation: Current compatibility DC to 0.01 second pulse width 0.025 mV
- Weight 0.34 kg
- Weight Note 0.34 kg (12.1 oz) including boot and batteries
- Width 76 mm
With the CL515-PLUS you can check and calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Stop carrying around a decade box and RTD resistance tables. The CL515-PLUS works with the RTDs you use including Platinum 100 (alpha = 3850, 3902, 3926) & 1000 (alpha = 3850, 3750) Ohm, Copper 10 & 50 Ohm, Nickel 100 and 120 Ohm. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer “DIAL” plus store any three temperatures for instant recall with the check switch. Calibrate quickly with automatic output stepping, choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds. Carry it without worry—it comes protected with a rubber boot and rugged, low profile switch. Easy to operate even in the dark areas of the plant with the back-lit display.