Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | International +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-V4

Item# Series-V4

In Stock

Lead Time (If not in stock): 0 week

Product Specs

<< See all Product Models
Brand
Applications Fluid Measurement and Control, HVAC, Oil, Pump Control, Fluid Measurement and Control, HVAC, Oil, Pump Control
Electrical Connection 3/4 in NPT male Conduit with Screw Terminal block, 3/4 in NPT male Conduit with Screw Terminal block
Enclosure Ratings Hazardous Location Rated, Weatherproof, Hazardous Location Rated, Weatherproof
Enclosure Ratings Note Weatherproof and Explosion-proof. **Listed with UL and CSA for Class I, Groups C and D; Class II, Groups E, F, and G. ATEX 2813 II 2 G Ex db IIB T6 Gb -20°C≤Tamb≤73°C, -20°C≤Process Temp≤73°C. EU-Type Certificate No.: KEMA 03 ATEX 2383. ATEX Standards: EN 60079-0:2012+A11:2013; EN 60079-1:2014. IECEx Certified: For Ex db IIB T6 Gb -20°C≤Tamb≤73°C. -20°C≤ProcessTemp≤73°C. IECEx Certificate of Conformity: IECEx DEK 11.0071.IECEx Standards: IEC 60079-0:2011; IEC 60079-1:2014. Zone I. Also FM approved., Weatherproof and Explosion-proof. **Listed with UL and CSA for Class I, Groups C and D; Class II, Groups E, F, and G. ATEX 2813 II 2 G Ex db IIB T6 Gb -20°C≤Tamb≤73°C, -20°C≤Process Temp≤73°C. EU-Type Certificate No.: KEMA 03 ATEX 2383. ATEX Standards: EN 60079-0:2012+A11:2013; EN 60079-1:2014. IECEx Certified: For Ex db IIB T6 Gb -20°C≤Tamb≤73°C. -20°C≤ProcessTemp≤73°C. IECEx Certificate of Conformity: IECEx DEK 11.0071.IECEx Standards: IEC 60079-0:2011; IEC 60079-1:2014. Zone I. Also FM approved.
Media Compatibility Clean dry air / inert gas, Clean process / cooling water, Compatible Liquids, Inert / non-reactive gases, Oils / lubricants, Organic solvents, Water, Alcohols, Argon, Compatible Gases, Compatible Liquids, Nitrogen, Oils, Water
Mounting Orientation ± 5° from Vertical, ± 5° from Vertical
Operating Temperature, Max 275 °F, 275 °F
Operating Temperature, Min -4 °F, -4 °F
Pipe Size, Min 1.5 in, 1.5 in
Process Connection Size 1 1/2 in, 1 1/2 in
Process Connection Type NPT Male, NPT Male
Process Temperature, Max 163 °F, 163 °F
Process Temperature, Min -4 °F, -4 °F
Series ID Series-V4
Set Point Adjustment Vane adjustments, Vane adjustments
Switch Rating 10 A @ 125/250 Vac, 10 A @ 125/250 Vac
Switch Rating Note UL, FM, ATEX and IECEx models 10 A @ 125/250 VAC (V~). CSA models: 5 A @ 125/250 VAC (V~); 5 A res., 3 A ind. @ 30 VDC(V ). MV option: 1 A @125 VAC (V~); 1 A res., .5 A ind. @ 30 VDC (V ). MT option: 5 A @ 125/250 VAC (V~). [MT and MV option not UL, CSA, FM, ATEX or IECEx], UL, FM, ATEX and IECEx models 10 A @ 125/250 VAC (V~). CSA models: 5 A @ 125/250 VAC (V~); 5 A res., 3 A ind. @ 30 VDC(V ). MV option: 1 A @125 VAC (V~); 1 A res., .5 A ind. @ 30 VDC (V ). MT option: 5 A @ 125/250 VAC (V~). [MT and MV option not UL, CSA, FM, ATEX or IECEx]
Weight 1.9 kg, 1.9 kg
Wire Gauge 16 AWG, 16 AWG