Product Specs
<< See all Product Models| Brand |
|
| Alarm | Audible: >98 dB @ 2' ; Relay: 1 form “C”, non-latching; 10 A @ 240 Vac, 8 A @ 24 Vdc, 1 ⁄2 hp @ 240 Vac ; Visual: Flashing “ALARM” message |
| Dew/Frost Point Accuracy | 0.2°C (± 0.5°F) |
| Dew/Frost Point Temperature Max | 50 °C |
| Display Type | LED |
| Electrical Output | 4 to 20 mA |
| Enclosure | Aluminium |
| Enclosure Ratings | IP55, NEMA Type 12 |
| Measurement Type | Dew Point |
| Mounting | Space-Saving Wall Mount |
| Operating Temperature, Max | 50 °C |
| Operating Temperature, Min | 0 °C |
| Output Detail | 4 to 20 mA (0 to 5 Vdc), -50 to 50°C (-58 to 122°F) or -60 to 75°C (-76 to 167°F) |
| Process Connection Size | 1/4 in |
| Process Connection Type | Compression Fitting |
| Process Temperature, Max | 50 °C |
| Sample Flow Rate | 0.5 to 5.0 scfh, Integral flow meter |
| Sample Pressure | 0 to 150 psig (higher pressures available, consult Engineering Department) |
| Supply Voltage | 90 to 250 Vac |
| Temperature Accuracy | ± 0.2 °C |
| Temperature Accuracy Note | ± 0.2 °C (± 0.5 °F) |
| See All Specs | |