CO-Room

Carbon Monoxide Sensor, 0-125 PPM Default, (250 PPM Max), Room Mount

  • Parking Garages
  • Arenas
  • Kitchens
  • Laundry Rooms
  • Warehouses
  • Loading Docks
  • Service Garages
  • School Bus Parking Areas
CO-Room
From
Carbon Monoxide Sensor, 0-125 PPM Default, (250 PPM Max), Room Mount CO-Room CO-Room
loading all models
Product Overview
  • Accuracy ± 2.5 %
  • Applications Access and Parking Control Systems, Building and Maintenance, Commercial and Industrial
  • Cable Type Insulated Shielded
  • Electrical Connection Screw Terminal
  • Electrical Life 200,000 cycles minimum with 1A @ 30 VDC
  • Electrical Output 4 to 20 mA, 2 to 10 Vdc
  • Factory Setting 0 – 125 ppm / 0 – 250 ppm Field Adjustable
  • Installation 4’ to 6’ above the floor
  • Material Construction Option none
  • Measuring Range 7500 sq. ft. maximum
  • Operating Humidity 15 to 90% RH, non-condensing
  • Operating Temperature, Max 104 °F
  • Operating Temperature, Min -4 °F
  • Power Consumption 6.6 W max
  • Repeatability +/- 1% of Reading
  • Response Time Less than 60 Seconds for 90% of step change
  • Sensor Life ~ 5 years under Normal Conditions
  • Sensor Type Electrochemical
  • Series ID CO-Room
  • Shelf Life 6 months
  • Storage Temperature, Max 68 °F
  • Storage Temperature, Min 32 °F
  • Supply Current 250 mA
  • Supply Voltage 22 to 26 Vac/Vdc
  • Tightening Torque 0.37 ft-lbs (0.5n-3m) Nominal
  • Time Delay 0 to 60 min
  • Wire Gauge 26 to 16 AWG

Supported Applications

The ACI CO Room Series is designed for the continuous monitoring of carbon monoxide (CO) levels, specifically targeting vehicle exhaust in non-hazardous areas. The series utilizes a wide spectrum electrochemical sensor to measure environmental CO concentrations.

  • Detection and monitoring of Carbon Monoxide (CO)

Operating Conditions & Performance

The transmitter operates within an ambient temperature range of -4°F to 104°F (-20°C to 40°C) and a humidity rating of 15 to 90% RH continuous, non-condensing; or 0 to 99% RH intermittent, non-condensing. The device is rated for atmospheric pressure +/- 10%. Performance specifications include an accuracy of +/- 2.5% of Reading and repeatability of +/- 1% of Reading.

  • Measurement Range: Factory set at 0 – 125 ppm; field adjustable to 0 – 250 ppm
  • Response Time: Less than 60 Seconds for 90% of step change
  • Sensor Life: ~ 5 years under Normal Conditions
  • Coverage Area: 7500 sq. ft; 49' Radius

Configuration Options

The series is offered in a standard NEMA 1 rated enclosure constructed from Polycarbonate/ABS Blend, UL94V-0. The unit features fixed terminal blocks for power wiring using 16 to 26 AWG (0.2 to 1.00 mm²) Shielded Twisted Pair cables.

Outputs and Indicators

  • Analog Outputs: 4-20 mA or 2-10V Jumper Selectable
  • Indicators (Optional): Alphanumeric, 2 line X 8 digit LCD; (2) Red LED's for Relay Status

Relay and Alarm Options

An optional configuration includes two SPDT Form C dry contact relays and a buzzer. The relay rating is 1A @ 30 VDC/0.5A @ 125 VAC (Resistive Load) with a life expectancy of 200,000 cycles minimum at 1A @ 30 VDC. Time delays for actuation and de-actuation are configurable from 0 to 60 Minutes in 5 minute Increments.

Power Supply

  • Voltage: 24 VAC +/- 10% Floating; 24 VAC +/- 10%, One side Grounded; or 24 VDC
  • Current Draw: 100 mA nominal | 250 mA maximum

Accessories and Maintenance

The series supports a Calibration Adapter, Replacement CO Sensing Element, and Gas Cal Kit. Sensors should be tested for accuracy every 6 months; recalibration or sensor replacement is required if necessary. When installed above 3000' above sea level, the transmitters must be verified for accuracy and re-calibrated after installation.

Key Product Differences

  • CO-R (Item #102151): CO Room Mount with Standard Room Enclosure.
  • CO-R-RB-D (Item #107556): CO Room Mount including Display, Relay, and Buzzer in a Standard Enclosure.

The series is not compatible with the Q4C II, M-Controller2, or Q-Controller. Modbus RTU communication is not supported by this product line.