Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | International +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here.

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

CNP-Series

Item# CNP-Series

In Stock

Lead Time (If not in stock): 0 week

Product Specs

<< See all Product Models
Brand
Accuracy ± 0.1 %
Accuracy Detail ±0.1% of input range ±1 LSD (T/C CJC better than 1°C)
Additional Features 1 Low Voltage Power
Approvals CE, UL and ULC recognized
Auto/Manual Selectable From front panel with bumpless transfer
Control Characteristics Enable control ON/OFF selectable from front keypad
Control Mode PID Control, On-off control
Control Output SPDT Relay, Alarm
Data Interface RS485
Data Interface Note 2-wire RS485, 1200 to 19,200 Baud, Modbus
Depth Behind Panel 100 mm
Display Type 4 Digit LED
Enclosure Ratings IP20, IP66
Front Panel Dimensions 96 x 48 mm
Impedance Input >10Ω for thermocouple and mV ranges, 47Ω for V ranges and 5Ω for mA ranges
Input Type Thermocouple, RTD, mA, Voltage
Input Type Note Thermocouple J, K, C, R, S, T, B, L, N and PtRh 20% vs PtRh 40% RTD 3 Wire PT100: 50Ω per lead maximum (balanced)
Keypad 4 button operation with LED display and indicators
Measurement Type Current, Temperature, Voltage
Number of Control Outputs 3
Number of Inputs 1
Operating Temperature, Max 55 °C
Operating Temperature, Min 0 °C
Output Configurations Up to 3
Output Detail 1 DC pulse, 2 SPDT 2A relay outputs;Control and Alarm Relays: Contacts SPDT 2 amp resistive at 240 Vac, >500,000 operations Output Configuration: up to 3 possible outputs for control and alarms. Control SSR Driver Outputs: >10 Vdc in 500 minimum drive capability Triac Outputs: 0.01 to 1 amp AC, 20 to 280 Vrms, 47 to 63 Hz Alarm Output: Process high, process low, SP deviation, band, logical or/and; also 1 loop alarm for process control security; process alarms have adjustable hysteresis
Output Signal DC Pulse
RTD Type 100 Ω Pt Sensor
Relative Humidity 20 to 95%
Sampling Rate 4 Hz (4 updates/second)
Sampling Rate Note 4 per second, 14 bit resolution approximately
Sensor Break Detection < 2 seconds (except zero based DC ranges), control O/P's turn off, high alarms activate for T/C and mV ranges, low alarms activate for RTD, mA or V ranges
Series ID CNP-Series
Storage Temperature, Max 80 °C
Storage Temperature, Min -20 °C
Supply Power Note 100 to 240 V, 50/60 Hz, 7.5 VA, 20 to 48 Vac 7.5 VA/22 to 65 Vdc, 5W
Supply Power Type AC
Supply Voltage 100 to 240 Vac
Thermocouple Type None
Weight 0.21 kg
See All Specs Show Less
1/16 and 1/8 DIN Vertical Plastics Extrusion Process Controllers CNP-Series CNP-Series
en-NL
en_NL
Save Configuration