Product Specs
<< See all Product Models| Brand |
|
| Accuracy | ± 0.1 % |
| Accuracy Detail | ±0.1% of input range ±1 LSD (T/C CJC better than 1°C) |
| Additional Features 1 | Low Voltage Power |
| Approvals | CE, UL and ULC recognized |
| Auto/Manual Selectable | From front panel with bumpless transfer |
| Control Characteristics | Enable control ON/OFF selectable from front keypad |
| Control Mode | PID Control, On-off control |
| Control Output | SPDT Relay, Alarm |
| Data Interface | RS485 |
| Data Interface Note | 2-wire RS485, 1200 to 19,200 Baud, Modbus |
| Depth Behind Panel | 100 mm |
| Display Type | 4 Digit LED |
| Enclosure Ratings | IP20, IP66 |
| Front Panel Dimensions | 96 x 48 mm |
| Impedance Input | >10Ω for thermocouple and mV ranges, 47Ω for V ranges and 5Ω for mA ranges |
| Input Type | Thermocouple, RTD, mA, Voltage |
| Input Type Note | Thermocouple J, K, C, R, S, T, B, L, N and PtRh 20% vs PtRh 40% RTD 3 Wire PT100: 50Ω per lead maximum (balanced) |
| Keypad | 4 button operation with LED display and indicators |
| Measurement Type | Current, Temperature, Voltage |
| Number of Control Outputs | 3 |
| Number of Inputs | 1 |
| Operating Temperature, Max | 55 °C |
| Operating Temperature, Min | 0 °C |
| Output Configurations | Up to 3 |
| Output Detail | 1 DC pulse, 2 SPDT 2A relay outputs;Control and Alarm Relays: Contacts SPDT 2 amp resistive at 240 Vac, >500,000 operations Output Configuration: up to 3 possible outputs for control and alarms. Control SSR Driver Outputs: >10 Vdc in 500 minimum drive capability Triac Outputs: 0.01 to 1 amp AC, 20 to 280 Vrms, 47 to 63 Hz Alarm Output: Process high, process low, SP deviation, band, logical or/and; also 1 loop alarm for process control security; process alarms have adjustable hysteresis |
| Output Signal | DC Pulse |
| RTD Type | 100 Ω Pt Sensor |
| Relative Humidity | 20 to 95% |
| Sampling Rate | 4 Hz (4 updates/second) |
| Sampling Rate Note | 4 per second, 14 bit resolution approximately |
| Sensor Break Detection | < 2 seconds (except zero based DC ranges), control O/P's turn off, high alarms activate for T/C and mV ranges, low alarms activate for RTD, mA or V ranges |
| Series ID | CNP-Series |
| Storage Temperature, Max | 80 °C |
| Storage Temperature, Min | -20 °C |
| Supply Power Note | 100 to 240 V, 50/60 Hz, 7.5 VA, 20 to 48 Vac 7.5 VA/22 to 65 Vdc, 5W |
| Supply Power Type | AC |
| Supply Voltage | 100 to 240 Vac |
| Thermocouple Type | None |
| Weight | 0.21 kg |
| See All Specs | |