Resumen del Producto
- Uniformidad del flujo ± 1 %
- flujo lineal, mín. 0 m/s
- Número de puertos 18
- ID de serie WT-3100-Wind-Tunnel
- Tensión de alimentación 24 V CC
- Dimensiones de la sección de prueba 60,9 L x 40,6 A x 8,2 P cm
- Distancia entre paredes 3,00 pulgadas
- Peso 51.7 kg
- Ancho 81.3 cm
Supported Applications
The Omega WT-3100 is an open loop benchtop wind tunnel designed for the thermal characterization of components, boards, and heat sinks. The unit features a unique polynomial shape nozzle engineered to create uniform flow within the test section.
Operating Conditions & Performance
The system produces airflow up to 2000 ft/min (10 m/s) using appropriate fans; higher speeds can be achieved by selecting different fan configurations. The open loop design includes a wall-to-wall spacing of 3.00" (7.6 cm), which is available as custom designed for specific applications.
Electrical operation requires a power supply of 24 volt-DC, with the constraint that voltage to the fans cannot exceed 26 Volts-DC. The unit weighs 130 lbs. (60 Kg.).
Configuration Options
The WT-3100 construction utilizes Aluminum, stainless steel, and Plexi-glass™ materials for the housing structure.
- Dimensions: 71" (180cm) length by 18" (45.7 cm) width with a test chamber depth of 3.2 in as indicated in the series title, and a wall-to-wall spacing of 3.00" (7.6 cm).
- Flow Range: Up to 2000 ft/min (10 m/s), configurable for higher speeds via fan selection.
- Power & Connections: Operates on a 24 volt-DC power supply with a Fan connector interface; maximum voltage limit is 26 Volts-DC.
The series supports optional accessories including sensors to measure flow parameters, a wind tunnel controller, and an optional data center accessory. The manufacturer holds ISO 9001 Certified Corporate Quality status for facilities in Stamford, CT and Manchester, UK.
Key Product Differences
The WT-3100 is offered as a single benchtop configuration with fixed overall dimensions of 71" (180cm) length and 18" (45.7 cm) width. While the standard wall-to-wall spacing is 3.00" (7.6 cm), this dimension can be custom designed for specific applications.
Performance variations are achieved through fan selection to alter flow speeds beyond the baseline up to 2000 ft/min (10 m/s). The unit includes a warning that these products are not designed for use in, and should not be used for, human applications.