Models In Stock
TX13-Smart-Temp-Tx
From  111,85
Models In Stock
Thermocouple Input Temperature Transmitter w/ Pushbutton Config TX13-Smart-Temp-Tx TX13-Smart-Temp-Tx
loading all models
Product Overview
  • Accuracy ± 5 µA
  • Accuracy Detail (mA output/2000) or 5 uA (whichever is the greater)
  • Approvals BS EN 61326 ; 1998 – Electrical equipment for measurement and control ANNEX A ; ANNEX F
  • Calibration Pushbutton
  • Cold Junction Compensation ±0.05°C/°C
  • Cold Junction Temperature Accuracy ±0.5 °C
  • Diameter 43 mm
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Height 21 mm
  • Humidity Range 10 to 90% RH non condensing
  • Input Accuracy ± 0.5 °C
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Output Load [(Vsupply-10)/20] kΩ
  • Probe Length 0 mm
  • Programmable Functions offset, Range, Sensor Burnout Indication, sensor type
  • Response Time 1 sec
  • Self Heating Effect 0.2 uA/V
  • Sensor Type Transmitter
  • Setup Controls Pushbutton, Program LED will flash in bursts
  • Sheath Material N/A
  • Stability Offset: 0.1°C/°C;Span: 0.05°C/°C
  • Start Up Time I out < 4 mA during start up
  • Storage Temperature, Max 90 °C
  • Storage Temperature, Min -50 °C
  • Supply Power Type DC
  • Supply Voltage 10 to 30 Vdc
  • Temperature Input Range K: -200 to 1370 °C; J: -100 to 1200 °C; E: -100 to 1000 °C; N: -180 to 1300 °C; T: -100 to 400 °C; R -10 to 1760 °C; S: -10 to 1760 °C
  • Thermal Effects 1 uA/°C
  • Update Rate, Max 500 ms
  • Warm Up Time 1 min to full accuracy
  • Weight 31 g
The TX13 in-head mounting thermocouple transmitter converts a thermocouple input over a configured range to a standard industrial (4 to 20 mA) transmission signal. A simple push button operation allows the user to select thermocouple type, burnout direction, select fixed ranges and trim 4 and 20 mA points. The in-head transmitter incorporates the latest digital technology to ensure accurate drift-free performance.
The default factory scaling is for a range of 0 to 1000°C and Type K thermocouple input, with up-scale burnout. 