Skip to search Skip to main content Skip to navigation

United Kingdom 0800 488 488 | Intl +44 (0) 161 777 6611 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-PTA

PWM to Analog Current / Voltage Output Interface Device

  • Converts PWM pulses to analog control: PTA modules convert a single pulse-width modulated input into a linear voltage or current output for control and automation applications.
  • Ideal for drive and actuator interfaces: Designed for variable speed pump drives, variable frequency fan drives, electric actuators, duty-cycle control, and digital-to-analog conversion.
  • Flexible input compatibility: Accepts relay contact closure, transistor, or triac pulse inputs with optically isolated signal handling and positive or negative polarity support.
  • Selectable voltage outputs: DIP-switch selectable ranges include 0-1 VDC, 0-4 VDC, 0-10 VDC, 0-13 VDC, 1-2 VDC, 1-5 VDC, 1-11 VDC, and 1-14 VDC.
  • Current output support: Provides selectable 0-16 mA or 4-20 mA output, plus adjustable 0-20 mA for custom applications.
  • Adjustable span and offset: Built-in potentiometers allow users to fine-tune minimum and maximum output levels beyond preset ranges.
  • Stable no-wrap output: Holds the last output value until the next pulse ends and prevents wraparound when an excessively long pulse is received.
  • High-resolution signal conversion: 256-step output resolution supports smooth analog control from pulsed digital commands.
  • Panel-friendly installation: Compact UL94 V-0 snaptrack package with 90° pluggable screw terminals supports clean interface-panel wiring.
  • Backed by ACI quality: RoHS2 and WEEE compliant, with ACI’s two-year limited warranty.
Series-PTA
From
PWM to Analog Current / Voltage Output Interface Device Series-PTA Series-PTA
loading all models
Product Overview
  • Input Type PWM
  • Operating Temperature, Max 120 °F
  • Operating Temperature, Min 35 °F
  • Series ID Series-PTA
  • Storage Temperature, Max 150 °F
  • Storage Temperature, Min -20 °F
  • Supply Voltage 24 Vac/Vdc
  • Voltage Output Field Selectable Analog Output

Supported Applications

The ACI Series PTA functions as a specialty signal conditioner that converts pulse-width modulated (PWM) inputs, timed contact closures, or solid-state closures into linear analog voltage or current outputs. The series is designed for applications including Pulse to Analog Transducer interfaces, Variable Speed Pump Drive Control, Frequency Fan Drive Control, Electric Actuator interfacing, Duty Cycle to Analog Control, and Digital to Analog Conversion.

Specific variants address distinct input sources: the PTA-PPM model converts Water Flow Meter Pulses (60 to 3000 Pulses/Min) into analog signals. The series accepts inputs from Relay Contact Closures, Transistors, or Triacs with optical isolation supporting either positive or negative polarity.

Operating Conditions & Performance

The Series PTA operates within an ambient temperature range of 35 to 120°F (1.7 to 48.9°C) and a humidity range of 10 to 95% non-condensing. Storage is supported from -20 to 150°F (-28.9 to 65.5°C). The device requires a power supply of 24 VDC (24-35 VDC) or 24 VAC (21.6-26.4 VAC), 50/60 Hz, with maximum current draw varying by output configuration.

Performance specifications vary by model and frequency:

  • Precision: The PTA series offers +/- 2% of span accuracy for adjustable ranges at 60 Hz (or +/- 3% at 50 Hz) and 5% for preset spans. The PTA2 variant specifies an accuracy of +/- 5%.
  • Resolution: Output resolution is documented as 256 steps for the PTA series and 255 steps for the PTA2 series.
  • Signal Hold Behavior: The last output signal is held until the device receives the end of the next pulsed input. Outputs do not wrap around if an excessively long input pulse is received.

Voltage and Current Output Limits

The series supports selectable voltage ranges including 0-1 VDC, 0-4 VDC, 0-10 VDC, 0-13 VDC, 1-2 VDC, 1-5 VDC, 1-11 VDC, and 1-14 VDC. Adjustable voltage ranges extend to 0-20 VDC (with adjustable offset). The PTA2 model is configured for a fixed 0-10 VDC output.

Current outputs include selectable spans of 0-16 mA and 4-20 mA, with an adjustable range of 0-20 mA (with adjustable offset) available on the PTA series. Load impedance requirements are:

  • Voltage Output: Minimum 3300Ω at 20 VDC +/- 10% or minimum 4000Ω at 10 VDC +/- 10%. The PTA2 requires a minimum of 400Ω.
  • Current Output: Maximum load impedance is 0 to 750Ω.

Pulse Timing Ranges

The series supports multiple input pulse timing configurations depending on the firmware version and model:

  • PTA Standard (Version #1): 0.02 to 5.0s, 0.1 to 10.0s, 0.59 to 2.93s, or 0.1 to 25.5s.
  • PTA Version #2: Supports Duty Cycle Pulse ranges including 0 to 10s (10 second window) and 0.023 to 6.0s.
  • PTA-PPM: Configured for Water Flow Meter Pulses at 60, 100, 1500, or 3000 Pulses/Min.
  • PTA2 Version #2: Supports Duty Cycle Pulse ranges of 0 to 10.0s (10s window), 0-25.5s (25.5 sec. window), 0-100s (100s window), and 0.023 to 6.0s.

Configuration Options

The Series PTA is configurable across several dimensions including output signal type, input pulse timing ranges, and mounting options. The device features a Polyvinyl Chloride (PVC) snap track with a UL94 V-0 flammability rating.

Electrical Connections

All models utilize 90° Pluggable Screw Terminal Blocks compatible with wire sizes from 16 AWG (1.31 mm²) to 26 AWG (0.129 mm²). The terminal block torque rating is specified as a minimum of 0.5 Nm and a maximum of 0.6 Nm.

Configuration Options

The PTA series includes DIP switch selectable spans for ten preset analog output signal ranges, alongside span and offset potentiometers for user adjustment. The input trigger level is configurable via jumpers or switches:

  • Normal Mode: 5 to 26.4 VAC/DC.
  • Triac Mode: 9 to 26.4VAC (requires triac adapter circuitry).

The PTA2 model includes a jumper-selectable manual override for output modulation verification between 0-10 VDC and supports Triac inputs via selectable jumpers.

Accessories

Available accessories include:

  • A/D0008 (Item #142583): Transient Voltage Suppressor, Bi-directional, 56VAC/DC, 1500W.
  • DIN Rail Adapter Kits: A/DRC 3.88 X 2.18 (Item #142623) for PTA; A/DRC 2.7 X 2.18 (Item #142626) for PTA2.
  • ENC1 (Item #102472): 20 Gauge Metal Enclosure designed to hold interface products.

Power Output Capability

The series provides a regulated power output of 24 VDC, limited to 48 mA maximum. This feature allows the device to supply power for external components within specified limits.

Key Product Differences

The Series PTA encompasses distinct model families with specific dimensional and functional differences:

  • PTA & PTA-PPM: These models support both voltage (0-14 VDC selectable, 0-20 VDC adjustable) and current outputs (0-16 mA, 4-20 mA). The standard PTA dimensions are (L) 3.75" x (W) 2.20" x (H) 1.15" (95.25 x 55.88 x 29.21 mm), weighing 0.24 lbs. The PTA-PPM is optimized for water flow meter pulse inputs.
  • PTA2 & PTA2 VERSION #2: These models are dedicated to voltage output only (0-10 VDC). They feature a smaller footprint with dimensions of (L) 2.20" x (W) 2.35" x (H) 1.00" (55.88 x 59.69 x 25.4 mm), weighing 0.18 lbs.

Both series variants carry RoHS2 and WEEE approvals where applicable, with the PTA datasheet explicitly listing these certifications alongside UL94 V-0 flammability ratings for the snap track material.

en-GB
en_UK
Save Configuration