Product Overview
  • Accuracy ± 2 %
  • Accuracy Detail ±2% of reading; ±5% below minimum transition rate
  • Calibration Option 3 POINT NIST
  • Certifications CE
  • Display Note 7-segment, 8-digit, single-line LCD
  • Display Type LCD
  • Enclosure Ratings IP68
  • Form factor 150 ANSI Flange
  • Materials Cast Iron, ABS
  • Materials, Wetted cast iron
  • Measurement Type Transit Time
  • Number of Digits 8
  • Number of Outputs 1
  • Measurement Pressure, Max 230 psi
  • Process Temperature, Max 50 °C
  • Process Temperature, Min 0 °C
The FDT500 Series comprises advanced-technology water flow meters. This series uses transit time ultrasonic technology in which the signal is transmitted and received alternately between 2 flow sensors and the "time of flight" determines the flow rate. The battery-powered transmitter comes in the users choice of an integrally mounted display or a remote mount version. Applications include both commercial and consumable water measurement. Long-term stability and a wide measurement range make it possible not only to measure water consumption, but also to monitor systems for water leakage. Because the FDT500 Series has no moving parts, system pressure loss is minimal and filtration is not required. Display flow rate or total at the push of a button. Installation is aided by 150-lb ANSI flanges in sizes from 2 to 8" or 32 to 200 DN.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Can the meter screen be flipped upside down so that we can read it? Our pipe setup for our lab has the direction of flow going from right to left so that when the meter is installed, the screen is upside down and can't easily be read.

Asked by: ADUD
Thank you for your inquiry! Unfortunately, the meter screen is not designed to be flipped in order to change orientation and should not be tampered with in this manner.
Answered by: Application Engineer JM
Date published: 2021-08-24

How do I change the battery? We have had the unit for almost a year but have never used it. Is there a tab or something to remove before use?

Asked by: Wallace
Thank you for your inquiry. In the manual, Section 6.3, has the information about the battery, battery life, and instructions on how to replace the battery. Here is the web link to obtain the manual https://www.omega.com/en-us/pdf-manuals and click on the E-G and then, scroll down to look for the general part number.
Answered by: JC ENGR
Date published: 2020-12-04

When connected to Vdc does this product still require the battery.

Asked by: NP ENGR
Thanks for your question. Yes. The meter still requires the battery when connected to VDC voltage supply.
Answered by: AE HPO
Date published: 2023-06-12
  • y_2025, m_11, d_3, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_FDT503, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration