Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

TXDIN400-Series-Tx

DIN Rail Transmitter with RFID Communications

  • Isolated &  Linearized
  • High Accuracy with 16-Bit Conversion
  • TXDIN401 Temperature Transmitter Accepts Pt100 or Ni100 RTD Inputs and Types J/K/T/E/R/S/B/N Thermocouples
  • TXDIN402 Accepts Process Voltage, Current or Resistance Input
TXDIN400-Series-Tx
From
DIN Rail Transmitter with RFID Communications TXDIN400-Series-Tx TXDIN400-Series-Tx
loading all models
Product Overview
  • Approvals CE, RoHS
  • CMRR 50 to 60 Hz
  • Electrical Connection Screw Terminal
  • Electrical Output FS + 5°C
  • Enclosure Ratings IP20, NEMA
  • Height 90 mm
  • Length 64 mm
  • Materials Polycarbonate, Silicone
  • Memory 2624 Word
  • Memory Note Non-Volatile Memory (Circular Buffer) for Data Logging
  • Mounting DIN Rail Mount
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Output Value Process
  • Relative Humidity 30 to 90% RH (non condensing)
  • Resolution Output Resolution: 2 μA
  • Sampling Rate 300 milliseconds between updates
  • Series ID TXDIN400-Series-Tx
  • Software Windows® XP/7/8 (32-bit and 64-bit), Windows 10 (64-bit)
  • Standard Limits of Error 0.1% FS or 0.2 °C whichever is greater
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Type Loop Powered
  • Weight 30 g
  • Width 18 mm

Supported Applications

The Omega TXDIN400 Series comprises DIN rail mount transmitters with RFID communications, designed for signal conditioning in industrial environments. The series includes two distinct models: the TXDIN401, a temperature transmitter accepting RTDs and thermocouples, and the TXDIN402, configured for process inputs including voltage, current, and resistance.

Both units are 2-wire loop-powered devices featuring a 4 to 20 mA output. Configuration is performed wirelessly using the TX400-RFID programmer connected via USB to a PC running free downloadable configuration software from Omega. The transmitters include non-volatile memory for data logging with user-selectable sampling times ranging from 1 to 3600 seconds.

Operating Conditions & Performance

The TXDIN400 Series operates within an ambient temperature range of -40 to 85°C (-40 to 185°F) and a storage temperature of -40 to 85°C (-40 to 185°F). Humidity ratings are specified as 30 to 90% RH (non condensing).

Performance specifications include a maximum transmission error of 0.1% FS or 0.2 °C whichever is greater, with a resolution of 2 μA and a response time of 600 msec (10 to 90%). The enclosure rating is NEMA 1 (IP20) according to CE, EN 61000-6-4, and EN 61000-6-2. Power supply requirements are met via a 2-wire loop-powered design with an operating range of 6 to 32 Vdc.

Configuration Options

The series supports multiple sensor types and process inputs across its two models, configurable for specific measurement needs:

  • TXDIN401 Temperature Inputs:
  • Pt100 RTD: α = 0.00385; 2, 3, or 4-wire connection; -200 to 600°C (-328 to 1112°F)
  • Ni100 RTD: α = 0.00618; 2, 3, or 4-wire connection; -60 to 180°C (-76 to 356°F)
  • Thermocouple J: -200 to 1200°C (-328 to 2192°F)
  • Thermocouple K: -260 to 1360°C (-436 to 2480°F)
  • Thermocouple T: -260 to 400°C (-436 to 752°F)
  • Thermocouple E: -260 to 940°C (-436 to 1724°F)
  • Thermocouple R: -40 to 1760°C (-40 to 3200°F)
  • Thermocouple S: -40 to 1760°C (-40 to 3200°F)
  • Thermocouple B: 40 to 1820°C (104 to 3308°F)
  • Thermocouple N: -260 to 1280°C (-436 to 2336°F)
  • mV Input: -10 to 70 mV
  • TXDIN402 Process Inputs:
  • Voltage: 0 to 10 V
  • Current: 0 to 20 mA (4 to 20 mA default)
  • Resistance: 0 to 4000 Ω

The enclosure is constructed of polycarbonate with a silicone front panel. Electrical connections are made via screw terminals. The device dimensions are 90 H x 18 W x 64 mm D (3.54 x 0.71 x 2.52") and weigh approximately 30 g (1.05 oz).

Key Product Differences

The TXDIN400 Series is differentiated by input type:

  • TXDIN401: DIN rail mount RFID temperature transmitter supporting Pt100, Ni100 RTDs, and thermocouples J/K/T/E/R/S/B/N.
  • TXDIN402: DIN rail mount RFID voltage, current, and resistance input transmitter.

Both models share the same physical housing, output signal (4 to 20 mA loop-powered), power requirements, memory capabilities for data logging, and wireless programming interface via the TX400-RFID programmer. Accessories include the TX400-RFID programmer supplied with a User Guide and USB interface cable, as well as DIN rails RAIL-35-1 (1 m length) and RAIL-35-2 (2 m length).

Accessories

accessories

RFID PROGRAMMER
TWD7,101 / each
14 In Stock

installation hardware

35MM DIN RAIL, 1 METER LENGTH
TWD790 / each
15 In Stock
en-TW
en_TW
Save Configuration