Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
TXDIN1600S-Transmitter
DIN Rail Strain Gage/Load Cell Transmitter w/ Bipolar mA/V Output
Models In Stock
- Suitable for Load Cell/Strain Gauge Applications
- Universal Current, Bipolar Voltage Outputs
- Input Range 0.2 to 7.5 MV/V, 5 V Excitation
- Powered 10 to 32 Vac or 10 to 48 Vdc Supply
TXDIN1600S-Transmitter
From
TWD
10,884
Models In Stock
Product Overview
- Approvals CE
- Approvals Note CE: BS EN 61326
- Baud Rate 19200
- Calibration Calibration Scaling: 2 to 6 points signal against process;Active Calibration:Active calibration against live load cell
- Data Interface USB
- Display Type LED
- Drift < ± 0.05%
- Electrical Output 0 to 21.5 mA
- Enclosure Ratings IP65
- Excitation Current 59 mA
- Filter 1 to 20 seconds to reach 70% of final value
- Height 90 mm
- Isolation 500 Vdc
- LED Indicators LED, Green when output -0.1 to 100.1%, all else red
- Length 56.4 mm
- Materials Polyimide 6.6
- Mounting DIN Rail 43880, Color Grey
- Offset Tare Input Type - Remote volt free contact, up to 10 meter distance
- Operating Temperature, Max 70 °C
- Operating Temperature, Min -30 °C
- Output Value Process
- Relative Humidity 10 to 90%RH (non condensing)
- Series ID TXDIN1600S-Transmitter
- Shell Color Gray
- Software Windows PC Software
- Supply Power Type AC/DC
- Update Rate 10 or 80 SPS
- Weight 70 g
- Width 17.5 mm
Supported Applications
The Omega TXDIN1600S is a smart powered bridge amplifier designed for strain gauge and load cell signal conditioning. It functions as a DIN rail mount transmitter that scales input signals to process values, supporting applications requiring voltage or current re-transmission of sensor data.
Operating Conditions & Performance
The TXDIN1600S operates with an ambient temperature range of -30 to 70°C (-22 to 158°F) and a storage ambient range of -30 to 70°C (-22 to 158°F). Configuration is specified for an ambient environment of 10 to 30°C (50 to 86°F). The device maintains operation within a humidity rating of 10 to 90% RH (non condensing) and features an enclosure protection level of IP65.
Performance specifications include bridge input linearity of ± 0.01% and drift less than ± 0.05%. The device utilizes ratio metric measurement for high stability with a sample rate selectable at 10 or 80 SPS (samples per second). Output accuracy is defined as (mA out/2000) or 5 µA whichever is the greater, with a drift of 1 µA/°C. Voltage output accuracy is ± 5 mV.
Measurement and Signal Parameters
- Bridge Input: -7.6 to 7.6 mV/V (-38 to 38) mV at 5V excitation; Four wire radimetric type.
- Bridge Excitation: 5 Volts DC ± 0.1 V @ 59 mA, supporting total bridge impedance from 85 to 10000 Ω (operates with four 350 Ω cell in parallel).
- Response Time: Filter selectable from 1 to 20 seconds to reach 70% of final value.
Configuration Options
The TXDIN1600S series supports configurable output signals, calibration scaling, and user interface options. The device is housed in a DIN rail enclosure (style DIN 43880) constructed from Polyimide 6.6 with dimensions of 56.4 mm width x 90 mm height x 17.5 mm depth.
Output Signal Options
- Current Source: Range (0 to 21.5) mA, max load 750 Ω.
- Current Sink: Range 0 to 21.5 mA, supply 10 to 30 Vdc, voltage effect 0.2 µA/V.
- Voltage Output: 0 to 10.1 V or -10.1 to 10.1 V with ± 2 mA current drive and min load 5000 Ω @ 10 V.
User Interface & Configuration
- Calibration: Supports (2 to 6) points signal against process scaling, including active calibration against live load cell and remote set tare offset with programmable user set point.
- Front Panel: Independent “Low” and “High” push buttons allow manual setting of low and high output points. LED indication shows green when output is -0.1 to 100.1%, red otherwise.
- Digital Interface: USB 2.0 at 19,200 baud for PC running Windows XP or later; supports process units (4 characters) and tag number (20 characters).
Power & Electrical Connections
- Supply: 10 to 48 Vdc, 10 to 32 Vac protected by internal 500 mA resettable fuse; power consumption < 1 W full power.
- Isolation: Supply to input to output 500 Vdc.
- Tare Input: Remote volt free contact, up to 10 meter distance.
- Terminals: Screw terminals accepting wire size maximum 2.5 mm (0.10").
Key Product Differences
The TXDIN1600S is a single model family designated as the DIN-rail mount load-cell transmitter. If configuration is not specified at the time of order, the product ships with default settings: 2 mV/V input and 4 to 20 mA output range.
PDFs & Manuals
Software & Drivers