Italia 800 906 907 | Internazionale +39 022 333 1521 | Benvenuti sul nostro nuovo sito web. Avete riscontrato un problema o un bug? Segnalatelo qui.
Therm-Outdoor-Air
Sensori di temperatura a termistore per aria esterna
Capteurs de température à thermistance pour air extérieur- Rilevamento della temperatura dell'aria esterna
- Impianti di conservazione a freddo
- Ambientazioni ad alto punto di rugiada/condensazione
- Unità a tetto
- Monitoraggio della temperatura dell'aria mista/di scarico/di mandata
- Centri dati
- Ospedali
Therm-Outdoor-Air
Da
Panoramica del Prodotto
- Matériau de l'alliage (-) Cuivre
- Matériau en alliage (+) Cuivre
- Applications Air et CVC, Bâtiment et entretien & service, Surveillance environnementale, Médical
- Connexion électrique Câbles pigtail
- Raccord PVC
- Isolation PTFE
- Longueur du câble 14 in
- Nombre de points de détection 1
- Nombre de fils 2
- Humidité de fonctionnement 10 à 95 % HR ; sans condensation
- Température de fonctionnement, max 115 °C
- Température de fonctionnement, min -40 °C
- Temps de réponse 25 secondes nominales
- ID de série Therm-Outdoor-Air
- Matériau de la gaine PVC
- Température de stockage, max 70 °C
- Température de stockage, min -40 °C
- Plage de mesure de la température -40 à 115 °C
- Longueur du tube 4.7 in
- Calibre du fil 22 AWG
Supported Applications
The ACI Thermistor Outside Air Series is a single-point outdoor temperature sensor designed for use with electronic controllers in commercial heating and cooling building-management systems. Each sensor uses a weatherproof enclosure with a water-tight cord-grip fitting, and the sensing element is built with ACI's double-encapsulation process to eliminate the effects of moisture ingress, making it well suited to permanent outdoor mounting.
The series is offered with a wide choice of thermistor curves so it can be matched to nearly any controller input, and with several enclosure styles for different mounting and environmental needs. Correct siting is important: mount the sensor out of direct sunlight on the north side of a building, in shade, below the eave and above the ground, and away from chimney walls, windows, vents, doors, and dampers so that thermal radiation does not affect the reading. Signal wiring must be kept separate from low- and high-voltage wiring and must not share conduit with line voltage (24/120/230 VAC).
Operating Conditions & Performance
The sensor operates over -40 to 70°C (-22 to 158°F), with the same range applying to storage. Accuracy across 0-70°C (32-158°F) is ±0.2°C (±0.36°F) for most series, ±0.3°C (±0.54°F) for the A/10K-E1 series, and ±0.5°C @ 25°C (77°F) for the A/1.8K series, which is also specified at (±1.0°C) (±1.8°F). The sensor is a non-linear NTC thermistor with a single sensing point and a nominal response time of 25 seconds (63% step change).
Operating humidity is 10 to 95% RH, non-condensing. The element terminates in two non-polarity-sensitive 14” (35.6 cm) 22 AWG (0.65 mm) etched Teflon (PTFE) colored leads, whose colors identify the sensor type. The sensors are CE marked and RoHS2 compliant.
Three enclosure styles are available. The “-EH” Euro enclosure is ABS/PC-ASA plastic with a UV protectant, rated UL94-V0. The “-4X” enclosure is polystyrene plastic, rated UL94-V2 and IP66 (NEMA 4X). The “-BB” Bell Box enclosure is aluminum, rated IP32 (NEMA 3R). Representative widths are 4.00” (101.57 mm) for the Euro enclosure, 2.55” (64.77 mm) for the NEMA 4X enclosure, and 2.95” (75 mm) for the Bell Box.
Configuration Options
Every model follows the pattern A/ - Sensor Series - Configuration - NIST (for example, A/CP-O-EH), so a code selects three independent capabilities:
- Sensor series (nominal resistance @ 25°C): A/1.8K is 1.8 KΩ, A/3K is 3 KΩ, A/AN (Type III) is 10 KΩ, A/AN-BC is 5.238 KΩ, A/CP (Type II) is 10 KΩ, A/CSI is 10 KΩ, A/10KS is 10 KΩ, A/10K-E1 is 10 KΩ, A/20K is 20 KΩ, A/50K is 50 KΩ, and A/100KS is 100 KΩ. The lead-wire color pair differs for each series to make them easy to tell apart.
- Configuration (enclosure): O-EH selects the Euro housing, O-BB selects the aluminum Bell Box, and O-4X selects the NEMA 4X enclosure, which sets the enclosure material and NEMA/IP rating as described above.
- NIST: models can be ordered with or without a NIST calibration certificate; the -NIST suffix adds the certificate.
Because accuracy, power-dissipation constant, and lead-wire colors are tied to the sensor series, selecting the series sets both the electrical characteristic the controller expects and the sensor's specified accuracy grade.
Key Product Differences
The series is offered in the following configured models:
- A/1.8K-O-4X, A/1.8K-O-BB, A/1.8K-O-EH
- A/3K-O-4X, A/3K-O-BB, A/3K-O-EH, A/3K-O-EH-NIST
- A/10KS-O-4X, A/10KS-O-BB, A/10KS-O-EH
- A/10K-E1-O-4X, A/10K-E1-O-BB, A/10K-E1-O-EH, A/10K-E1-O-EH-NIST
- A/20K-O-4X, A/20K-O-BB, A/20K-O-EH
- A/50K-O, A/50K-O-4X, A/50K-O-BB
- A/100KS-O-4X, A/100KS-O-BB, A/100KS-O-EH
- A/AN-BC-O-4X, A/AN-BC-O-BB, A/AN-BC-O-EH, A/AN-O-EH-NIST
- A/CP-O-4X, A/CP-O-4X-NIST, A/CP-O-BB, A/CP-O-EH, A/CP-O-EH-NIST
- A/CSI-O-4X, A/CSI-O-BB, A/CSI-O-EH
NIST-certified variants add a NIST calibration certificate to the corresponding base model.
PDF & Manuali