Gage-Pressure-Transducer

Gage Pressure

  • Reliable gage pressure measurement with stable 4–20 mA output for process monitoring and control 
  • Stainless steel diaphragm with welded design and no O-rings for broad media compatibility
  • Available in a range of pressure spans from low PSI up to higher industrial ranges
Gage-Pressure-Transducer
À partir de
Gage Pressure Gage-Pressure-Transducer Gage-Pressure-Transducer
loading all models
Aper çu du produit
  • Connexion électrique Connecteur Packard
  • Immunité CEM Remarque 150 V/m
  • Matériau du boîtier Aluminium avec joint en silicone
  • Couple de serrage 150 lb-in (16,95 Nm) nominal
  • Résistance de charge 800 Ohms @ 24 VCC
  • Température de fonctionnement, max 257 °F
  • Température de fonctionnement, min -40 °F
  • Signal de sortie Courant
  • Pression, min 0 psi
  • Type de pression Manomètre
  • Taille du raccordement au process 1/4 po
  • Type de raccordement au process NPT mâle
  • Protection +/- 16 V pendant 5 minutes
  • Humidité relative 1 à 95 % HR, sans condensation
  • Temps de réponse < 1 ms
  • ID de série Gage-Pressure-Transducer
  • Stabilité +/- 0,03 % FS à 0 PSIG ; +/- 0,12 % FS à 1000 PSIG
  • Température de stockage, max 176 °F
  • Température de stockage, min -40 °F
  • Courant d'approvisionnement 25 mA
  • Tension d'alimentation 13 à 30 Vcc ; 18 à 30 Vcc
  • Effet thermique sur l'erreur d'étendue, max 15 à 60 psig : < +/- 1,0 FS
  • Vibration 145 Heures
  • Poids 0.3 lb
  • Remarque sur le poids Série A/GP-NEMA 4 : 0,34 lbs (0,15 kg) Harnais A/GP 6’ : 0,20 lbs (0,09 kg) Harnais A/GP 20’ : 0,62 lbs (0,28 kg) Harnais A/GP 2’ : 0,06 lbs (0,03 kg) Harnais A/GP 10’ : 0,32 lbs (0,14 kg) Harnais A/GP 30’ : 0,92 lbs (0,41 kg)

Supported Applications

The GP Series gage pressure transducers are 4 to 20 mA, loop-powered devices built for commercial, industrial, and process-control applications that demand excellent accuracy and reliability. At the heart of each unit is a bulk micro-machined transducer with a stainless steel diaphragm and fully welded construction that contains no O-rings, making the sensor compatible with any gas or liquid compatible with 304L stainless steel.

That robust wetted path suits a broad media list — refrigerants, glycol, motor oil, diesel, hydraulic fluid, brake fluid, water, waste water, hydrogen, nitrogen, and air. Typical applications include refrigeration, fuel cells, pumps, hydraulics, and compressors, where the transducer's fast response and rugged diaphragm hold up to real-world service.

Two sensing types are offered: Gage (psig) models measure pressure relative to the atmosphere, while the Sealed Gage (psis) model references a sealed chamber. Sealed Gage transducers are not vented to atmosphere but are calibrated to deliver 4 mA at 14.5 PSIG so they resemble a standard gauge output. The sensor connects through a ¼"-18 NPT male thread and a Packard connector, with wire harnesses ordered separately.

Operating Conditions & Performance

The GP Series outputs a 4 to 20 mA (2-wire, loop-powered) signal with a response time of < 1 ms. Accuracy — which includes hysteresis, repeatability, and non-linearity (BFSL) — is specified by range at 22°C (71.6°F): < +/- 1.0% FS for 15 to 60 psig, and < +/- 0.5% FS for 75 to 300 psig and for 500 psis.

Electrical and environmental limits include:

  • Supply voltage: +13 to 30 VDC (250 Ohm load); +18 to 30 VDC (500 Ohm load)
  • Supply current: 25 mA
  • Maximum load resistance: 800 Ohms @ 24 VDC
  • Reverse polarity protection: +/- 16 V over 5 minutes
  • Storage temperature: -40 to 176°F (-40 to 80°C)
  • Operating humidity: 0 to 95% RH, non-condensing
  • Proof and burst pressure: 3x Full Scale

The transducer is rated over a wide operating temperature band of -40 to 257°F (-40 to 125°C) and withstands demanding mechanical stress, with vibration endurance across 100 to 2000 Hz (20g sinusoidal, 3 axes) for 144 Hours and thermal shock cycling between 105°C and -40°C. The compact stainless steel body measures 2.60" (66.6 mm) x 0.87" (22.23 mm), with an overall length of 2.77" (70.36 mm) including the connector. The series carries CE, RoHS2, WEEE, and ISO 9001 credentials.

Configuration Options

Model selection turns on three choices: pressure range, sensing type, and whether the transducer is supplied inside a weatherproof enclosure. The bare-transducer GP(<range>)-20-P models provide the sensor with a Packard connector, with an optional NEMA 4 rated weatherproof metal enclosure available. The A/GP(<range>)-20-P-N4 models come already mounted in a NEMA 4 enclosure and are rated NEMA 4, 4X, 6, 6P, 12 and 13 (Compare to IP68) for outdoor and washdown environments.

Across both families, ranges span 0-15 psig (103 kPa) up to 0-300 psig (2069 kPa) as Gage sensors, plus a 0-500 psis (3447 kPa) Sealed Gage version. Every model natively provides the 4 to 20 mA output; a 1-5 VDC signal can be obtained with an optional 250 Ohm load resistor, and a 2-10 VDC signal with an optional 500 Ohm load resistor. All models require a harness (ordered separately) and share the 304L stainless steel wetted diaphragm.

Key Product Differences

Each transducer is ordered by its full-scale range, encoded in the model number. The bare GP transducers and the enclosure-mounted A/GP-N4 versions share the same seven ranges:

  • GP(0-15G)-20-P / A/GP(0-15G)-20-P-N4 — 0-15 psig (103 kPa), Gage
  • GP(0-30G)-20-P / A/GP(0-30G)-20-P-N4 — 0-30 psig (207 kPa), Gage
  • GP(0-50G)-20-P / A/GP(0-50G)-20-P-N4 — 0-50 psig (345 kPa), Gage
  • GP(0-100G)-20-P / A/GP(0-100G)-20-P-N4 — 0-100 psig (689 kPa), Gage
  • GP(0-200G)-20-P / A/GP(0-200G)-20-P-N4 — 0-200 psig (1379 kPa), Gage
  • GP(0-300G)-20-P / A/GP(0-300G)-20-P-N4 — 0-300 psig (2069 kPa), Gage
  • GP(0-500S)-20-P / A/GP(0-500S)-20-P-N4 — 0-500 psis (3447 kPa), Sealed Gage

Field accessories are ordered separately and include Packard wire harnesses in plenum-rated and metal-clad lengths, ¼" NPT stainless steel snubbers for air/gas (A/0.25"SNUB A/G) or water/light oils (A/0.25"SNUB WTR), precision load resistors for voltage-output conversion, and a GP NIST calibration certificate.