Product Overview
- Accuracy ± 5 µA
- Accuracy Detail (mA output/2000) or 5 uA (whichever is the greater)
- Approvals BS EN 61326 ; 1998 – Electrical equipment for measurement and control ANNEX A ; ANNEX F
- Calibration Pushbutton
- Cold Junction Compensation ±0.05°C/°C
- Cold Junction Temperature Accuracy ±0.5 °C
- Diameter 43 mm
- Electrical Connection Screw Terminal
- Electrical Output 4 to 20 mA
- Height 21 mm
- Humidity Range 10 to 90% RH non condensing
- Input Accuracy ± 0.5 °C
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Output Load [(Vsupply-10)/20] kΩ
- Probe Length 0 mm
- Programmable Functions offset, Range, Sensor Burnout Indication, sensor type
- Response Time 1 sec
- Self Heating Effect 0.2 uA/V
- Sensor Type Transmitter
- Series ID TX13-Smart-Temp-Tx
- Setup Controls Pushbutton, Program LED will flash in bursts
- Sheath Material N/A
- Stability Offset: 0.1°C/°C;Span: 0.05°C/°C
- Start Up Time I out < 4 mA during start up
- Storage Temperature, Max 90 °C
- Storage Temperature, Min -50 °C
- Supply Power Type DC
- Supply Voltage 10 to 30 Vdc
- Temperature Input Range K: -200 to 1370 °C; J: -100 to 1200 °C; E: -100 to 1000 °C; N: -180 to 1300 °C; T: -100 to 400 °C; R -10 to 1760 °C; S: -10 to 1760 °C
- Thermal Effects 1 uA/°C
- Update Rate, Max 500 ms
- Warm Up Time 1 min to full accuracy
- Weight 31 g
Supported Applications
The Omega TX13 is a smart in-head transmitter designed to connect to standard thermocouple sensors and convert temperature measurements into a linear (4 to 20) mA signal. It accepts inputs from Type K, J, E, N, T, R, and S thermocouples as well as mV signals. The device features galvanic isolation and is intended for use in industrial locations where it converts sensor output over a configured range into a standard transmission signal.
Operating Conditions & Performance
The TX13 operates within an ambient temperature range of -40 to 85°C (-40 to 185°F) and supports humidity levels from 10 to 90% RH non-condensing. Storage temperatures are rated for -50 to 90°C (-58 to 194°F). The transmitter achieves a response time of 1 second to reach 90% of the final value, with an update time of 0.5 seconds and a typical start-up time of 5 seconds from power up.
Accuracy specifications vary by sensor type as documented in the series data sheet:
- Type K: -200 to 1370 °C (-328 to 2498 °F) with ±0.5°C (0.9°F) or ±0.1% whichever is greater
- Type J: -100 to 1200 °C (-148 to 2192 °F)
- Type E: -100 to 1000 °C (-148 to 1832 °F)
- Type N: -180 to 1300 °C (-292 to 2372 °F)
- Type T: -100 to 400 °C (-148 to 752 °F)
- Types R and S: -10 to 1760 °C (14 to 3200 °F), with accuracy specified over the range 800 to 1600°C
- mV Input: -10 to 70 mV with ±0.02% of full scale accuracy
The output signal is a two-wire (4 to 20) mA sink, capable of low limits at 3.8 mA and high limits at 21.5 mA for burnout indication.
Configuration Options
The TX13 series supports configuration via a single pushbutton menu system indicated by 'M' and 'R' LEDs, allowing users to reconfigure transmitter parameters including input type and range selection from 56 preprogrammed ranges. The device includes user trim functionality for nulling out sensor error and programmable burnout with a sensor fail indicator.
Key configurable options include:
- Housing: DIN standard probe head enclosure (43 mm diameter x 21 mm height) providing protection from moisture, dust, and corrosive atmospheres. The manual notes the device conforms to EC directive BS EN 61326:1998 when installed in a termination head providing at least IP20 protection.
- Power Supply: Operates on 10 to 30 Vdc (example load resistance calculation provided for 24V supply).
- Connections: Screw terminal electrical connection with center hole sensor wire entry. Sensor input wires must be less than 3 m (10') to comply with EMC standards.
- Options and Accessories: Available options include TX-SCALED for factory setup of range, PSR series regulated power supplies (24 Vdc), and TX2-100 shielded cables.
Key Product Differences
The primary variation within the TX13 family is defined by the selected thermocouple type or mV input, which dictates the available measurement range. If a specific range is not specified at order time, the transmitter ships with a default configuration of 0 to 1000°C (32 to 1832°F) Type K upscale burnout.
Model variations are distinguished by:
- Sensor Input: Selection between Types K, J, E, N, T, R, S, or mV determines the valid temperature span and accuracy class.
- Output Configuration: The device functions as a two-wire (4 to 20) mA sink with specific low/high limits for fault indication.