Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

HX94B-Srs-Temp-RH-Sig-Cond

Temperature/RH Conditioner/Transmitter Probe w/ 4 Output Options

Models In Stock
  • RoHS Certified
  • Accurate to ± 2.5% Relative Humidity and ± 0.6°C (± 1°F) Temperature
  • Two Separate Analog Outputs, Humidity and Temperature
  • Four Analog Outputs available, 4 to 20 mA, 0 to 1V, 0 to 5V, 0 to 10V
HX94B-Srs-Temp-RH-Sig-Cond
From TWD 18,937
Models In Stock
Temperature/RH Conditioner/Transmitter Probe w/ 4 Output Options HX94B-Srs-Temp-RH-Sig-Cond HX94B-Srs-Temp-RH-Sig-Cond
loading all models
Product Overview
  • Accuracy ±0.6 °C
  • Accuracy Detail ± 0.6ºC from 0 to 50ºC (32 to 122ºF), ± 1.25ºC from 50 to 100ºC (122 to 212ºF), ± 2.5 % from 20 to 80% RH, ± 3.5% from 5 to 20% and 80 to 95% RH, ± 4% from 0 to 5% and 95 to 100% RH
  • Enclosure Material 316 Stainless Steel, NEMA 4; non-NPT version includes IP68-rated cable gland, Stainless Steel
  • Enclosure Ratings NEMA Type 4
  • Hysteresis ± 1%RH
  • Lead Length 1.8 m
  • Length 258 mm
  • Load Resistance [(V supply - 4V)/0.02A)] -50; 200Ω @ 9V supply or 1250Ω @ 30V supply
  • Loop Resistance Note 1.25 kΩ
  • Measurement Type Temperature, Humidity
  • Operating Temperature, Max 100 °C
  • Operating Temperature, Min 0 °C
  • Outer Diameter 19 mm
  • Relative Humidity 0 to 100% RH
  • Relative Humidity Accuracy ± 2.5% RH
  • Relative Humidity Response Time 8 sec
  • Repeatability ± 0.2°C
  • Response Time 5 to 30 sec
  • Sampling Rate 0.25 Hz (4 seconds between updates)
  • Sensor Type Digital sensor
  • Series ID HX94B-Srs-Temp-RH-Sig-Cond
  • Supply Power Type DC
  • Supply Voltage 9 to 30 Vdc

Supported Applications

The HX94B Series is a temperature/relative-humidity transmitter for duct or wall mounting that delivers a linearized, temperature-compensated output for both temperature and relative humidity. The digital sensor is protected by a removable stainless steel cap, and the NEMA 4 stainless steel enclosure with sealed cable entry provides weather-tight protection for HVAC, environmental-monitoring and process applications.

Depending on the model selected, the transmitter provides a 4 to 20 mA, 0 to 1 Vdc, 0 to 5 Vdc or 0 to 10 Vdc output. Each unit includes mounting hardware and comes complete for direct installation.

Operating Conditions & Performance

The transmitter measures relative humidity across 0 to 100% RH and temperature across 0 to 100°C (32°F to 212°F). Humidity accuracy is ±2.5% from 20 to 80% RH, widening to ±3.5% from 5 to 20% and 80 to 95% RH and ±4% from 0 to 5% and 95 to 100% RH, with hysteresis of ±1%RH. Temperature accuracy is ±0.6°C from 0 to 50°C (32°F to 122°F) and ±1.25°C from 50 to 100°C (122°F to 212°F), with repeatability of ±0.2°C.

Response time is 5 seconds minimum, 30 seconds maximum for temperature and 8 seconds typical for humidity. The unit is powered from 9 to 30 Vdc @ 100 mA and drives a maximum current-loop resistance of 200Ω @ 9V supply up to 1250Ω @ 30V supply. The probe is 19 mm (0.75 in) in diameter and 258 mm (10.15 in) long, with an insertion depth of 25 to 214 mm (1 to 8.44 in), and weighs 200 g (7 oz) with the mounting kit. The 316 stainless steel enclosure is rated NEMA 4 (IP66), and the series is CE marked with an NIST-traceable calibration option (CAL-3-HU).

Configuration Options

The twelve variants differ along two axes: output signal and electrical connection. The output code sets the signal — C for 4 to 20 mA, V0 for 0 to 1 Vdc, V1 for 0 to 5 Vdc and V2 for 0 to 10 Vdc.

The connection style then determines termination. Base models (for example HX94BC) terminate in a 4-pin connector; W models (such as HX94BCW) bring out 1.8 m (6ft) stripped lead wires through a liquid-tight cable gland; and NPT models (such as HX94BCNPT) add a ½" male NPT fitting with lead wires.

Key Product Differences

The full lineup pairs each of the four outputs with each of the three connection styles:

  • HX94BC, HX94BV0, HX94BV1, HX94BV2 — 4-pin connector versions
  • HX94BCW, HX94BV0W, HX94BV1W, HX94BV2W — stripped lead-wire versions
  • HX94BCNPT, HX94BV0NPT, HX94BV1NPT, HX94BV2NPT — ½" male NPT fitting versions

Accessories include the HX94-MC spare 4-pin mating connector, the PSR-24S, PSR-24L and PSR-24L-230 regulated power supplies, the CAL-3-HU NIST-traceable calibration, and TX4-100 / TX4W-50 shielded cables.

en-TW
en_TW
Save Configuration