Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

HTS-HANI-CLAMP-I

Industrial Metal Pipe Clamp HANI Temperature Sensor

  • Non-invasive temperature measuring fluid inside the pipe
  • No process downtime or welding needed for install
  • Installation in a matter of seconds with clamping mechanism
  • As accurate as an invasive sensor, ± 0.50 to ± 1.0 °C accuracy
HTS-HANI-CLAMP-I
From
Industrial Metal Pipe Clamp HANI Temperature Sensor HTS-HANI-CLAMP-I HTS-HANI-CLAMP-I
loading all models
Product Overview
  • Accuracy ± 0.5 °C (± 0.9 °F)
  • Accuracy Detail ± 1.0°C from factory and improved accuracy to ± 0.5°C possible with in-situation 1 or 2-point calibration
  • Applications Industrial and Manufacturing
  • Base Mounting Metal Pipe
  • Electrical Connection M12 8 pin Female
  • Enclosure Ratings IP65
  • Height 2.03 in
  • Length 2.53 in
  • Loop Resistance (Vsupply -8V)/0.24 A
  • Materials Nylon, Silicone, Brass, Stainless Steel
  • Media Compatibility Clean process / cooling water, Water-based fluids
  • Mounting Clamp
  • Operating Temperature, Max 40 °C
  • Operating Temperature, Min 0 °C
  • Output Detail 4 to 20 mA User scalable analog output, default scaling 0-100°C
  • Output Signal Current
  • Process Temperature, Max 100 °C
  • Process Temperature, Min 0 °C
  • Response Time t63: 5 sec ; t90: 10 sec
  • Series ID HTS-HANI-CLAMP-I
  • Supply Power Note 8 VDC - 28 VDC (loop powered)
  • Supply Voltage 8 to 28 Vdc
  • Width 2.38 in

Supported Applications

The Omega HANI™ Clamp Sensor is a high accuracy non-invasive temperature sensor designed for industrial applications. It utilizes hybrid temperature sensing technology to measure fluid temperature inside metal pipes without penetrating the pipe wall or requiring process shutdowns.

Operating Conditions & Performance

This series measures liquid temperatures in the range of -20 to 100 °C (-4 °F to 212 °F). The sensor is specified for use with water and water-based fluids, though other process mediums are available upon request. It requires a straight pipe section at least 2.5" long for mounting.

Performance specifications include an accuracy of ±0.5 °C (±0.9 °F) to ±1.0 °C (±1.8 °F), depending on calibration status, with fluid flowing. The response time is documented as 5 sec (t63) and 10 sec (t90). Ambient operating temperature limits are 0 to 40 °C (32 to 104 °F).

Configuration Options

The HANI series supports a configurable envelope of pipe sizes, output options, and connectivity interfaces.

  • Pipe Diameters: Standard configurations are available for nominal industrial metal pipes in 1", 2", 2.5", 3", and 4" diameters. Other sizes are offered upon request.
  • Housing & Materials: The sensor construction includes PA12, silicone rubber, nickel-plated brass, and stainless steel components. It carries an IP67 rating when mated.
  • Electrical Output: A 4 to 20 mA loop-powered analog output is provided via an M12 8-Pin connector. The power supply requirement is 8 VDC - 28 VDC (loop powered).
  • Smart Core Features: All units are Omega Smart Core enabled, supporting data logging, plug-and-play device detection, alarms, notifications, and SYNC configuration.

Omega Link Interfaces & Accessories

The series integrates with the following optional interfaces to enable wireless or wired communication protocols:

  • IF-001: USB Smart Interface
  • IF-002: RS485/Modbus Smart Interface
  • IF-006-1-NA: Wireless Interface 915 MHZ (for North America)
  • IF-006-1-EU: Wireless Interface 868 MHZ (for Europe)

Cabling and connection accessories include the M12.8-T-SPLIT shielded T-splitter, field install connectors with screw terminals, and dual M12-8 connector cables in lengths of 1 m (3.3"), 3 m (9.8"), or 5 m (16.4") available as straight or right-angle terminators.

Key Product Differences

Variants within the series are distinguished by pipe diameter and calibration options:

  • Pipe Size Codes: Model numbers reflect specific diameters (e.g., 1.0I, 2.0I, 2.5I, 3.0I, 4.0I).
  • Calibration Options: Models with the CAL-3 suffix include a factory calibration certificate based on three points at 10 °C, 50 °C, and 90 °C.
  • User Calibration: A CAL-4 option is available for user-selected temperature point counts and values; this requires contacting the manufacturer for a quote.

Accessories

cables

Smart Probe M12 8 pin sheilded T Splitt
TWD1,670 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
Dual M12 Cables for Sensors and Transmitters
TWD1,797 / each
2 In Stock
Dual M12 Cables for Sensors and Transmitters
TWD1,797 / each
0 In Stock
Dual M12 Cables for Sensors and Transmitters
TWD2,236 / each
19 In Stock
Dual M12 Cables for Sensors and Transmitters
TWD2,236 / each
0 In Stock
Dual M12 Cables for Sensors and Transmitters
TWD2,699 / each
4 In Stock
Dual M12 Cables for Sensors and Transmitters
TWD2,589 / each
3 In Stock
Field Mountable M8 and M12 Connectors
TWD1,625 / each
45 In Stock

signal conditioners

Modbus compatible USB Serial to Smart Probe Interface
TWD2,792 / each
14 In Stock
en-US
en_TW
Save Configuration