Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
OMNI-AMP-IV-Srs-TC-Amp
Rugged Epoxy Encapsulated Thermocouple Amplifier
- 100% Encapsulated
- 2µV/°C Zero Stability
- 0.025°F/°F Reference Junction Stability
- Up or Downscale TC Burn-out
OMNI-AMP-IV-Srs-TC-Amp
From
TWD
22,023
Product Overview
- Bandwidth 3 dB down at 1.5 Hz 40 dB/decade roll-off
- CMRR 120 dB min @ 60 Hz
- Cold Junction Compensation ± 0.045°C/°C
- Common Mode Voltage +10 to -10 Vdc or 20 Volts peak-to-peak ac
- Electrical Output ± 10 V into 10 kΩ min
- Height 73 mm
- Impedance Input 2 MΩ
- Input Noise 0 to 1.5 Hz: 1.4 µVRMS (RTI)
- Input Range 40 to 1500
- Length 51 mm
- Long Term Stability Zero: ± 1µV/Month;Span: ± 0.05%; Stability of zero point - 2 µV/°C , Span stability - ± 0.01%/°C
- NMRR 80 dB min @ 60 Hz
- Non-Linearity ± 0.005 %
- Operating Temperature, Max 55 °C
- Operating Temperature, Min 0 °C
- Output Signal Voltage
- Programmable Functions Trim Pot
- Protection Output Protection: Continuous short circuit proof, Input Protection: Up to 115 Vac or Vdc common mode or differential Output Port
- Resolution Infinite
- Series ID OMNI-AMP-IV-Srs-TC-Amp
- Storage Temperature, Max 80 °C
- Storage Temperature, Min -20 °C
- Supply Power 115 Vac @ 3 VA max
- Supply Power Type AC
- Weight 455 g
- Width 95 mm
Supported Applications
The Omega OMNI-AMP IV is a high-performance, rugged epoxy encapsulated thermocouple amplifier designed for signal conditioning in industrial environments. It provides amplification and cold junction compensation for Type E, J, T, or K thermocouples using a 10 mV/°F scale factor. The series also accommodates Types R, S, and B when configured with the optional 1 mV/°F scale factor option.
Operating Conditions & Performance
The amplifier operates within an ambient temperature range of 0 to 55°C (32 to 130°F) and supports a storage temperature from -20 to 80°C (-4 to 175°F). It delivers a ±10 VDC output into a minimum load resistance of 10 kΩ. Performance specifications include an input impedance of 2 MΩ (differential), infinite resolution, and nonlinearity of ±0.005%. Stability after a 30-minute warm-up is rated at 2 μV/°C (1 μV/°F) for zero drift and ±0.01%/°C (±0.006%/°F) for span stability, with long-term span stability of ±0.05%. The unit features a frequency response that rolls off 40 dB/decade after dropping 3 dB at 1.5 Hz.
Electrical protection includes input tolerance up to 115 VAC or DC common mode or differential, and the output is continuous short circuit proof. Noise rejection capabilities include a Common Mode Rejection Ratio (CMRR) of 120 dB minimum @ 60 Hz and a Normal Mode Rejection ratio of 80 dB minimum @ 60 Hz.
Key Performance Metrics
- Cold Junction Compensation: ±0.045 °C/°C (±0.025 °F/°F)
- Noise (RTI) 0 to 1.5 Hz: 1.4 μVRMS
- Common Mode Range: +10 to -10 VDC or 20 Volts peak-to-peak AC
- Power Consumption: 3 VA maximum @ 115 VAC (or 230 VAC)
Configuration Options
The OMNI-AMP IV series is configurable across several dimensions to meet specific installation and measurement needs. The unit features rugged terminal strips for electrical connections, requiring a screwdriver for termination.
Housing and Mounting
- Enclosure: Rugged epoxy encapsulated housing (100% encapsulated).
- Dimensions: 73 H x 95 W x 51 mm D (2.87" x 3.75" x 2.0").
- Weight: 455 g (18 oz).
- Mounting Options: Supplied with bolts for standard mounting; a DIN rail mounting kit is available as accessory model number DIN400.
Signal and Power Configuration
- Scale Factor: 10 mV/°F (standard) or 1 mV/°F (optional for Types R, S, B).
- Burnout Direction: Configurable as Up Scale (-01 code) or Down Scale (-02 code).
- Power Supply: Available in 115 VAC @ 3 VA maximum (code -115, range 105 to 125 Volts AC, 50-60 Hz) or 230 VAC (code -230, range 210 to 250 Volts AC, 50-60 Hz).
Key Product Differences
The series is distinguished by the thermocouple type supported and the resulting scale factor. Models ending in "3" (e.g., OMNI-AMP IV-13-115) utilize a 10 mV/°F output for Types J, K, T, and E. Models ending in "4" (e.g., OMNI-AMP IV-14-115) utilize a 1 mV/°F output specifically for Types R, S, and B.
Model numbers further differentiate the burnout direction: codes starting with "1" indicate Up Scale (increase in temperature), while codes starting with "2" indicate Down Scale (decrease in temperature). The final digits denote the power line voltage compatibility (-115 for 105 to 125 VAC, -230 for 210 to 250 VAC).
Wire color coding is provided per thermocouple type: J (White/Red), K (Yellow/Red), T (Blue/Red), E (Purple/Red), and R/S/B (Black/Red). The terminal strip assignments include dedicated terminals for OUTPUT, CMN, AMBIENT OUT, +INPUT, -INPUT, and AC power connections.