Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OMB-DAQ-USB-2401

Portable USB Thermocouple/Voltage Input Data Acquisition Module

Models In Stock
  • 8 Differential or 16 Single- Ended Analog Inputs
  • 24 Bit Resolution with Up to 1000 Samples/Sec
  • User Programmable for Type J, K, T, E, R, S, B, N Thermocouple or Voltage Input
  • Free Windows Software Suite Available for Download from OMEGA - DAQ Central Menu Driven Windows Software and Also .NET API/Driver for Visual Basic, C#, and Visual C++ for Windows XP, Vista and Windows 7
OMB-DAQ-USB-2401
From TWD 39,962
Models In Stock
Portable USB Thermocouple/Voltage Input Data Acquisition Module OMB-DAQ-USB-2401 OMB-DAQ-USB-2401
loading all models
Product Overview
  • Accuracy ± 0.02 %
  • Analog I/O Note Analog Input Note: TC Input;Thermocouple Accuracy: In very slow mode, 24 bit resolution: J = ±1.1°C, K = ±1.2°C, T = ±1.1°C, E = ±1.0°C, R = ±2.5°C, S = ±2.6°C, B = ±3.3°C, N = ±1.5°C ;Cold Junction Compensation Accuracy: ±1.0°C;Analog Input Accuracy;Differential Input: In very slow mode, 0.015% of reading +0.004% of range +10uV (exclusive of noise);Single-End Input: In very slow mode, 0.05% of reading +0.01% of range +50uV (exclusive of noise);Open Thermocouple Detect: Automatically enable when a channel is configured for a thermocouple sensor
  • Configuration Parameters User-Configurable Input/Output
  • Data Interface Ethernet, USB 1.1, USB 2.0
  • Data Interface Note Configuration Method: DAQ Central Software;Supported Operating System: Microsoft Windows®XP SP2 / VISTA/7
  • Digital Output 12 Vdc
  • Height 39 mm
  • Input Configuration Connected Software
  • Input Type Thermocouple, Voltage
  • Isolation 500V from PC
  • LED Indicators Power and Activity LEDs Blink
  • Length 128 mm
  • Mounting DIN-Rail or Wall Mount
  • Number of Channels, Input Analog: 16 SE/8 DIFF
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Relative Humidity 0 to 95% RH non-condensing
  • Series ID OMB-DAQ-USB-2401
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note Powered direct from USB port, max 500 mA, or from external 7.5 to 12 Vdc, External Excitation Output Voltage: 12 Vdc regulated, max total current output 67 mA
  • Supply Voltage 5 Vdc
  • Voltage Measurement Range ±10V, ±500 mV, ±5V,±250 mV, ±2.5V, ±125 mV, ±2V, ±75 mV, ±1V, ±30 mV
  • Weight 0.23 kg
  • Width 107 mm

Supported Applications

The Omega OM-DAQ-USB-2401 is an 8/16-channel thermocouple and voltage input USB data acquisition module designed for portable data acquisition applications. The series supports user-programmable inputs for Type J, K, T, E, R, S, B, and N thermocouples or software-configurable voltage ranges from -30 to 30 mV up to ±10 V full scale.

Documented use cases include benchtop operation, DIN rail mounting in rack applications, or wall-mounted permanent installations. The module is designed for dry, moisture-free indoor environments only and includes built-in cold junction compensation and open thermocouple detection when channels are configured for thermocouple sensors.

Operating Conditions & Performance

The OM-DAQ-USB-2401 operates within an ambient temperature range of 0 to 50°C (32 to 122°F) and a relative humidity rating of 0 to 95% RH non-condensing. Storage temperatures are specified from -40 to 85°C (-40 to 185°F). The device provides 24-bit resolution with sequential measurement at approximately 1 ms per channel, achieving up to 1000 samples per second total across all active channels.

Performance specifications vary by input type and mode. In very slow mode (typical), thermocouple accuracy is listed as J = ±1.1°C, K = ±1.2°C, T = ±1.1°C, E = ±1.0°C, R = ±2.5°C, S = ±2.6°C, B = ±3.3°C, and N = ±1.5°C. Cold junction compensation accuracy is ±1.0°C.

Analog input accuracy in very slow mode (typical) is 0.015% of reading + 0.004% of range +10uV for differential inputs, and 0.05% of reading + 0.01% of range +50uV for single-ended inputs (exclusive of noise). The module provides 500 V isolation between the input channels and the PC.

Configuration Options

The series supports configurable channel types on a per-channel basis, allowing mixed thermocouple and voltage measurements within the same unit. Power is supplied directly from a USB port (max 500 mA) or via an optional external power adaptor rated +7.5 to +12 Vdc.

  • Input Ranges: Thermocouples Type J (-18 to 1200°C), K (-129 to 1372°C), T (-101 to 400°C), E (-184 to 1000°C), R (204 to 1768°C), S (204 to 1768°C), B (538 to 1820°C), and N (-129 to 1300°C). Voltage inputs include -10 to 10V, -5 to 5V, -2.5 to 2.5V, -2 to 2V, -1 to 1V, -500 to 500 mV, -250 to 250 mV, -125 to 125 mV, -75 to 75 mV, and -30 to 30 mV.
  • Excitation: Provides +12 Vdc regulated output with a maximum total current of 67 mA for sensor excitation.
  • Connectivity: USB 2.0 full-speed interface compatible with USB 1.1 and USB 2.0 ports; supports up to 10 DAQ units per PC via self-powered or USB-powered hubs.
  • Mounting Options: Includes hardware for wall mounting (drill holes 5.50 inches apart) or DIN rail mounting adaptors.

Key Product Differences

The OM-DAQ-USB-2401 is the primary model in this series, described as an 8/16-channel thermocouple/voltage input USB data acquisition module. The unit ships with Omega DAQ Central software and includes a mounting kit (screws, brackets, DIN rail adaptors), terminal blocks, a universal power adaptor, and two Type K insulated beaded wire thermocouples.

Accessory options available for the series include spare 1.83 m USB cables (OM-DAQ-USB-CABLE), spare 9 Vdc universal power adaptors (UNIV-AC-100/240), and additional terminal blocks (OM-DAQ-USB-TB). The device is not designed for medical or nuclear applications, nor should it be operated in flammable or explosive environments.