OM-EL-GFX-Series
Portable Temperature/Humidity Data Loggers With Graphing Display
Models In Stock
- Graphic LCD Shows Real-Time Readings, Graph and Current Status
- Memory: 252,928 Readings
- On Screen Menu and Graphing to Start, Stop, Review and Restart the Logger in the Field
- Micro USB Interface for PC Based Set-Up and Data Download
OM-EL-GFX-Series
From
TWD
9,272
Models In Stock
Product Overview
- Battery Size and Type 1/2 AA Li-ion
- Data Interface USB
- Display Type LCD
- Display Type Note High contrast graphic backlit LCD
- Enclosure IP67 with USB cover attached
- Enclosure Note IP67 with USB cover attached(excludes OM-EL-GFX-DTC, OM-EL-GFX-TC and OM-EL-GFX-DTP)
- Enclosure Ratings IP67
- Form factor Handheld
- Series ID OM-EL-GFX-Series
- Supply Power Type Battery
- Width 48.5 mm
Supported Applications
The Omega OM-EL-GFX Series comprises portable data loggers designed for temperature, relative humidity, dew point, and thermocouple measurements. These units feature a high-contrast graphic LCD display with real-time graphing capabilities, allowing users to monitor conditions directly on the device or download historical data via Micro USB connectivity using included Windows software.
Documented measurement functions include:
- Temperature only: Internal sensor monitoring for general environmental tracking.
- Temperature & Humidity: Simultaneous recording of temperature and relative humidity, with calculated dew point values available on specific models (40 to 100% RH @ 25°C).
- Thermocouple Inputs: Support for Type K, J, and T thermocouples in single or dual-channel configurations.
- External Thermistor Probes: Dual channel support for external thermistor probes (OM-EL-GFX-DTP), including options with sealed glycol-filled chambers for temperature stabilization.
Operating Conditions & Performance
The series operates within an ambient range of -10 to 40°C (-14 to 104°F). Measurement ranges and accuracy vary by model configuration:
- OM-EL-GFX-1 (Temperature): Range -30 to +80°C (-22 to 176°F); Accuracy ±0.1°C (±0.2°F) typical, ±0.5°C (±1.0°F) maximum.
- OM-EL-GFX-2 & OM-EL-GFX-2-PLUS (Temp/Humidity): Temperature range -30 to +80°C (-22 to 176°F); Humidity 0 to 100% RH. Accuracy for temperature is ±0.5°C (±1.0°F) typical / ±2.0°C (±4.0°F) maximum on OM-EL-GFX-2, and improved accuracy of ±0.2°C (±0.4°F) typical / ±0.8°C (±1.6°F) maximum on OM-EL-GFX-2-PLUS.
- OM-EL-GFX-DTC & OM-EL-GFX-TC (Thermocouple): Supports Type K (-200 to +1350°C / -328 to +2462°F), Type J (-200 to +1190°C / -328 to +2174°F), and Type T (-200 to +390°C / -328 to +734°F). Accuracy is ±0.5°C (±0.9°F) typical.
- OM-EL-GFX-DTP (Thermistor): Range -40 to 125°C (-40 to 257°F); Resolution 0.1°C (0.2°F).
All models provide a memory capacity of 256,000 readings and are powered by two replaceable ½ AA 3.6V lithium batteries (Part No: OM-EL-BATT), offering approximately one year of battery life.
Configuration Options
The series offers configurable options for housing protection, sensor inputs, and accessories to address specific logging requirements:
- Housing & Protection: Models OM-EL-GFX-1, OM-EL-GFX-2, and OM-EL-GFX-2-PLUS feature IP67 rugged construction when the USB cover is attached. Other models (DTC, TC, DTP) do not carry this rating.
- Display & Interface: All units include a 128x128 backlit graphic screen for tabular or graphical data display and three input buttons for operation. A Micro USB interface enables PC-based setup and data download; the unit can also be powered continuously via a wall adapter.
- Start/Stop Logic: Logging can initiate immediately, at a delayed time (e.g., 10:30:00), or upon reaching a specific temperature/RH threshold. Users can mute alarms and reset summary data on-device.
- Accessories & Probes:
- Included mounting clip with integrated magnet for wall or metal surface attachment.
- Spare thermistor probes (OM-EL-PROBE-TP-2-1M) and higher accuracy options (OM-EL-PROBE-TP-A-3M, OM-EL-PROBE-TP-A-GLY-3M) for the DTP model.
- Extension cables available in 1.5 m (5'), 5 m (16.5'), and 10 m (33') lengths for thermistor probes.
Key Product Differences
The OM-EL-GFX Series is differentiated by sensor type, channel count, and physical dimensions:
- OM-EL-GFX-1: Single-channel internal temperature logger. Dimensions: 88 H x 48.5 W x 30.5 mm D (3.46 x 1.91 x 1.20"). Weight: 99 g (3.5 oz).
- OM-EL-GFX-2 & OM-EL-GFX-2-PLUS: Internal temperature and humidity loggers with varying accuracy levels. Dimensions match the GFX-1.
- OM-EL-GFX-DTC: Dual-channel thermocouple logger (K, J, T types). Includes two free 1 m Type K insulated beaded wire thermocouples. Dimensions: 102 H x 48.5 W x 30.5 mm D (4.06 x 1.91 x 1.20"). Weight: 105 g (3.7 oz).
- OM-EL-GFX-TC: Single-channel thermocouple logger. Includes one free Type K insulated beaded wire thermocouple.
- OM-EL-GFX-DTP: Dual-channel external thermistor probe logger. Dimensions: 101 H x 48.5 W x 30.5 mm D (3.98 x 1.91 x 1.20"). Includes two standard thermistor probes with stainless steel tips.
PDFs & Manuals
Software & Drivers