Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

XCIB

High Temperature Inconel Overbraided Silica Fiber Insulated Thermocouples

Models In Stock
  • High Temperature Ceramic Insulation with Inconel Overbraid
  • Flexible, Abrasion Resistant
  • Withstand Temperatures up to 1090 °C (2000 °F)
  • Unexcelled Oven and Furnace Profiling
XCIB
From TWD 3,461
Models In Stock
High Temperature Inconel Overbraided Silica Fiber Insulated Thermocouples XCIB XCIB
loading all models

Can't find the right model?

Use our custom configurator to fine tune your product

Product Overview
  • Mounting Bolt-on
  • Process Temperature, Max 1038 °C
  • Process Temperature, Min 0 °C
  • Series ID XCIB
  • Sheath Material Inconel® 600
  • Washer Inner Diameter 0.1563 in
  • Washer Length 1 in
  • Washer Width 0.375 in
  • Wire Gauge 20 AWG
  • Wire Type Solid

Supported Applications

The XCIB Series comprises High-Temperature Inconel® Overbraided Silica Fiber Insulated Thermocouples. Each sensor is double-protected with an abrasion-resistant Inconel® overbraid over high-temperature fiber insulation, giving it the mechanical durability and thermal endurance needed for demanding heat-treatment environments.

These thermocouples are designed for oven and furnace profiling, where flexible, rugged sensors must survive repeated exposure to extreme heat. They are available in 5 convenient styles (1–5) for easy application and can be supplied in J, K, E and N thermocouple types to suit a wide range of process control and calibration tasks.

The sheath is Inconel 600®, and the probe diameter is 4.8 mm (3/16"). For assemblies that must ship with a calibration, use the prefix CAL- on the model number.

Operating Conditions & Performance

The XCIB thermocouples withstand 980°C (1800°F) continuous service and 1038°C short-term. The Inconel 600® overbraid and high-temperature fiber insulation are what allow this dual continuous/short-term rating in oven and furnace profiling.

A range of electrical terminations is offered, each with its own temperature limit. Ceramic beaded leads with compensated spade lugs and Nextel® insulated leads with compensated spade lugs are available for direct high-temperature runs, while connectorized options include the OMEGA® OSTW male standard thermocouple connector rated to 220°C (425°F) and the OMEGA® NHXH high-temperature ceramic male connector rated to 650°C (1200°F). Miniature options include the SMPW mini-male connector to 220°C (425°F) max and the SHX mini-male ceramic connector to 650°C (1200°F) max.

Configuration Options

Within the series, models differ along four independent axes: thermocouple type, probe style, termination type and length.

Thermocouple type sets the alloy pair and useful range: J is Iron-Constantan, K is CHROMEGA®-ALOMEGA®, E is CHROMEGA®-Constantan, and N is OMEGALLOY®-NICROSIL-NISIL.

Probe style selects one of the 5 convenient styles (1–5), while termination type chooses how the sensor is connected:

  • 1: Ceramic beaded leads with compensated spade lugs.
  • 2: Type OSTW male standard thermocouple connector to 220°C (425°F).
  • 3: Type NHXH male ceramic connector to 650°C (1200°F).
  • 4: Nextel® insulated leads with compensated spade lugs.
  • 5: Stripped leads.
  • 6: SMPW mini-male connector to 220°C (425°F) max.
  • 7: SHX mini-male ceramic connector to 650°C (1200°F) max.

Length is specified in feet, with 3' or 10' as the standard options. A grounded or ungrounded junction can be specified, and a Nextel-insulated version is available at no extra charge by changing the XCIB prefix to XSIB.

Key Product Differences

Model numbers follow the structure XCIB-<thermocouple_type>-<probe_style>-<termination_type>-<length_in_feet>. For example, XCIB-K-1-3-10 designates a Type K probe, probe style 1, termination Type 3, at a 10' length. Representative catalog numbers include XCIB-K-4-2-10, XCIB-J-4-3-3, XCIB-E-4-1-10 and XCIB-N-4-5-10, along with the ungrounded XCIB-K-4-2-10-UNGROUNDED.

The XSIB equivalents, such as XSIB-K-4-1-10 and XSIB-J-4-2-3, substitute Nextel® insulation for the same configurations. Custom lengths and sizes are available, and connector plug options can be appended to the model number: add 'M8-S-M' or 'M12-S-M' for a male straight M8 or M12 plug, or 'M8-R-M' for a male right-angled M8 plug.