Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-HHT

Hazardous Area Humidity/Temperature Transmitter, 4-20 mA Output

  • FM approved explosion-proof and intrinsically safe models
  • Integral LCD option
  • Dual temperature and relative humidity output models
Series-HHT
From TWD 73,945
Hazardous Area Humidity/Temperature Transmitter, 4-20 mA Output Series-HHT Series-HHT
loading all models
Product Overview
  • Current Output 4 to 20 mA
  • Electrical Connection 1/2 in NPT female Conduit with Screw Terminal block
  • Hysteresis ± 1%
  • Materials Housing Material: Aluminum
  • Measurement Type Relative Humidity
  • Operating Temperature, Max 140 °F
  • Operating Temperature, Min -40 °F
  • Output Detail 4-20 mA, 2 channels for humidity/temperature models (loop power on RH)
  • Output Signal Current
  • Relative Humidity 0 to 100% RH
  • Relative Humidity Accuracy ± 2% RH
  • Relative Humidity Input Range 0 to 100% RH
  • Repeatability ± 0.1%
  • Response Time 15 s
  • Series ID Series-HHT
  • Storage Temperature, Max 176 °F
  • Storage Temperature, Min -40 °F
  • Supply Power Type DC
  • Temperature Drift <1% RH/year
  • Weight 1134 g

Supported Applications

The Series HHT Hazardous Area Humidity/Temperature Transmitter is built to take accurate measurements in the harshest of environments. It is offered in explosion-proof and intrinsically-safe versions so the same measurement platform can be specified for classified areas such as chemical processing, oil and gas facilities, spray and paint operations, and other locations where flammable gases, vapors, or dusts may be present.

The explosion-proof models provide a humidity output, while the intrinsically-safe models are available for humidity only or for combined humidity and temperature; the intrinsically-safe versions require an intrinsically-safe barrier to meet their hazardous-area approvals. An aluminum enclosure rated NEMA 4X (IP66) lets the transmitter be mounted outdoors or in wash-down and corrosive settings, and a 1/2 female NPT conduit connection with a screw terminal block simplifies field wiring.

Operating Conditions & Performance

The transmitter measures relative humidity over 0 to 100% RH and temperature over -40 to 140°F (-40 to 60°C). Relative humidity accuracy is ±2% across 10 to 90% RH, and temperature accuracy is ±0.9°F at 77°F (±0.5°C at 25°C). Hysteresis is ±1%, repeatability is ±0.1% typical, and drift is specified at less than 1% RH per year. Resolution is 0.1% RH for humidity and 0.1°F (0.1°C) for temperature, with a response time of 15 s.

The unit is rated for storage over -40 to 176°F (-40 to 80°C). The output is a 4 to 20 mA signal, provided as two channels on humidity/temperature models with loop power on the RH channel. Power requirements depend on the protection method: intrinsically-safe HHT-IX models operate on 9.5 to 28 VDC, and explosion-proof HHT-EX models operate on 16.5 to 28 VDC.

The Series HHT is FM approved and CE marked. It is not field serviceable and should be returned if repair is needed. Use electrostatic-discharge precautions during installation and wiring, and avoid locations subject to severe shock or vibration, excessive moisture, or corrosive fumes.

Configuration Options

Models differ in three ways: the type of hazardous-area protection, the parameters measured, and whether an LCD is fitted.

  • Protection: explosion-proof models are designed to contain an internal ignition, while intrinsically-safe models limit energy in the circuit and require an intrinsically-safe barrier. This distinction also sets the supply-voltage window — 16.5 to 28 VDC for explosion-proof units versus 9.5 to 28 VDC for intrinsically-safe units.
  • Measured parameters: explosion-proof models output humidity only, whereas the intrinsically-safe range includes both humidity-only and combined humidity/temperature versions. Combined models provide two 4 to 20 mA channels.
  • Display: LCD versions add a local display of the measured value; non-LCD versions transmit only.

Key Product Differences

The Series HHT model chart comprises:

  • HHT-EU — explosion-proof, humidity, no display.
  • HHT-IU — intrinsically safe, humidity, no display.
  • HHT-IT — intrinsically safe, humidity/temperature, no display.
  • HHT-EU-LCD — explosion-proof, humidity, with display.
  • HHT-IT-LCD — intrinsically safe, humidity/temperature, with display.

Available accessories include the A-287 mounting bracket for pipe or surface mounting and the A-450 replacement sintered filter.

Accessories

accessories

Loop Powered, Intrinsically Safe Isolator
TWD30,248 / each
0 In Stock

installation hardware

A-287 MTG BRKT W/2" UBOLT
TWD2,496 / each
0 In Stock

sensors

A-451 HHT REPLCMNT SENSOR
TWD4,375 / each
0 In Stock