Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

CT7300-Series

Economical 2 Channel Circular Process Recorder

  • Universal Input
  • 2 Pen Circular Process Recorder, 254 mm (10' Chart)
  • Quick, Easy Setup
  • Easy-to-Replace Paper Chart with Magnetic Hub
CT7300-Series
From
Economical 2 Channel Circular Process Recorder CT7300-Series CT7300-Series
loading all models
Product Overview
  • Accuracy ± 0.5 %
  • Accuracy Detail Chart Recording: ±0.5% of span (100-division span)
  • Alarm modes Active High Output, Active Low Output, Adjustable, Band, High/Low, Manual reset
  • Approvals CE
  • Battery life 48 hr
  • Battery Size and Type Alkaline 9V
  • Chart Diameter 254 mm
  • Chart Speed Configurable—4, 8, 12, 24, 48 and 168 hours of rotation
  • CMRR >120 dB @ 60 Hz
  • Current Measurement Range 4 to 20 mA
  • Cutout Dimensions 323 x 323 mm
  • Deadband Set at 2 units; activation is safe-sided
  • Height 356 mm
  • Input Note Input Filtering: Up to 120 sec;Input Isolation: PV inputs isolated from all alarm outputs
  • Length 97 mm
  • Measurement Range Note Thermocouple: J: -130 to 760°C, K: -130 to 1370°C, T: -200 to 400°C, R: 0 to 1650°C, S: 0 to1649°C, B: 100 to 1824°C RTD: -210 to 440°C Current: 4 to 20 mA Voltage: 0 to 5 Vdc
  • Measurement Type Thermocouple, RTD, Current, Voltage
  • Mounting Vertical Mount (±20 Degrees), Horizontal Mount (±10 Degrees)
  • Mounting Orientation ± 20 degrees of vertical, ± 10 degrees of horizontal
  • Number of Channels 2
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min 0 °C
  • Pen Type Ink Style
  • Power Consumption 15 VA
  • Relative Humidity 0 to 90% RH, non-condensing
  • RTD Type 100 Ω Pt Sensor
  • Sensor Break Detection Error Protection: De-Energized During Sensor Break; Sensor Break: <10 sec
  • Series ID CT7300-Series
  • Standard Limits of Error Error Limit: Cold-Junction Compensation Error: ±0.2°C/°F @ 25°C, Ambient Temperature Error Limit: 0.01% of span per °C
  • Storage Temperature, Max 65 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note 110/220 Vac, 50/60 Hz
  • Supply Power Type AC
  • Supply Voltage 110/220 Vac
  • Switch Rating 1 A @ 120 Vac
  • Switch Rating Note DPDT, 1.0 A @ 120 Vac resistive
  • Switch Type DPDT
  • Temperature Measurement Range J: -130 to 760°C, K: -130 to 1370°C, T: -200 to 400°C, R: 0 to 1650°C, S: 0 to1649°C, B: 100 to 1824°C, RTD: -210 to 440°C
  • Thermocouple Type J, K,T, R, S, B
  • Vibration 0.3 to 100 Hz @ 0.2 g
  • Voltage Measurement Range 0 to 5 Vdc
  • Weight 3 kg
  • Width 356 mm
  • Wire Code Option 3- Wire
The CT7300 is an economical 2-pen circular process chart recorder that measures and records up to two process variables from a variety of inputs. Record and optional alarm settings are easily configured for multiple recording applications. To protect your process, the CT7300 battery back-up will continuously record up to 48 hours in the event of a power power loss.
NOTE: CT7300 series recorder is intended for both channels to have identical inputs and ranging

Accessories

consumables

PAPER, CIRCULAR, 100 QTY
$64.08 / each
61 In Stock
PAPER, CIRCULAR, 100 QTY
$67.70 / each
12 In Stock
PAPER, CIRCULAR, 100 QTY
$67.70 / each
13 In Stock
PAPER, CIRCULAR, 100 QTY
$67.70 / each
13 In Stock
PENS, GREEN, PKG 0F 6
$129.34 / each
6 In Stock
PENS, RED, PKG OF 6
$115.26 / each
14 In Stock

meters/controllers

PAPER, CIRCULAR, 100 QTY
$67.70 / each
25 In Stock
en-US
en_TW
Save Configuration