FD-400-Series

Doppler Ultrasonic Flow Meter

  • Non-Intrusive, Clamp-On Transducer for Most Pipes from 6 mm to 3m (1/4 to 120')
  • Insertion Probe Transducer Also Available
  • Wide Measuring Range of 0.05 to 9 mps (0.15 to 30 fps)
  • ±2% of Calibrated Span Accuracy
FD-400-Series
From TWD 112,932
Doppler Ultrasonic Flow Meter FD-400-Series FD-400-Series
loading all models
Product Overview
  • Accuracy ± 2 %
  • Accuracy Detail ±2% FS over calibrated span
  • Cable Length 6 m
  • Calibration Option NIST
  • Display Note 2-line x 8-character LCD; LED backlighting; top row, 7-segment 18 mm (0.7"); bottom row, 14-segment 9 mm (0.35"); 8-digit rate, 8-digit total (resettable)
  • Display Type LCD
  • Enclosure Ratings IP66, NEMA Type 4X
  • Form factor Wall Mount
  • Keypad Yes
  • Materials Polycarbonate, Stainless steel, Brass, Plated-steel mounting brackets
  • Measurement Type Doppler Ultrasonic
  • Number of Digits 8
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Pipe Size, Max 120 in
  • Pipe Size, Min 0.3333 in
  • Response Time 1 to 60 sec
  • Series ID FD-400-Series
  • Supply Power Note 115/230 Vac, 50/60 Hz ±15% @ 5 VA max; 12 to 28 Vdc @ 2.5 VA max
  • Velocity, Max 9 m/s
  • Velocity, Min 0.05 m/s

Supported Applications

The Omega FD-400 Series Doppler Ultrasonic Flow Meter measures liquid flow rate using non-invasive clamp-on transducers or insertion probes. The series is designed for liquids containing suspended solids, gas bubbles, or other sonic reflectors greater than 100 microns at a concentration of 100 ppm. Documented media include water, wastewater, sewage, slurries, and chemicals.

Applications leverage the clamp-on installation method to measure flow on existing pipes without cutting or disrupting service. The system supports synchronization for up to four meters in a single piping system spaced up to 30 m (100') apart.

Operating Conditions & Performance

The FD-400 Series operates with a flow velocity range of 0.05 to 9 mps (0.15 to 30 fps). Accuracy is specified as ±2% FS over the calibrated span, with user-selectable response times from 1 to 60 seconds.

Operating conditions vary by transducer type:

  • Ambient Temperature (Monitor): -40 to 85°C (-40 to 185°F)
  • Process Temperature (Standard Clamp-On & Insertion Probe): -40 to 100°C (-40 to 210°F)
  • Process Temperature (High-Temp Clamp-On): -40 to 200°C (-40 to 400°F)
  • Pressure Rating: Up to 700 psi (48 bar) max for insertion probes; clamp-on ratings depend on pipe integrity.

The monitor enclosure is rated NEMA 4X (IP66). Standard clamp-on transducers are rated NEMA 6P (IP68), while high-temperature clamp-ons are rated NEMA 4 (IP65).

Configuration Options

The series offers a wide range of configuration options for power, output signals, and sensor installation methods.

  • Power Supply: Standard units accept 115/230 Vac (±15%, 5 VA max) or 12 to 28 Vdc (2.5 VA max). Specific power options are selected at order placement via model suffixes.
  • Output Signals: Models provide various combinations of 4-20 mA, rate pulse outputs, and control relays. The 4-20 mA output supports a load resistance up to 800 Ω max with optically isolated circuitry.
  • Relay Outputs: Dual relay configurations are available as form 'C', rated at 200 Vac @ 0.5 A resistive, configurable for rate alarm, totalizer pulse, or error indication.
  • Pulse Output: Rate pulse options include two types: 500 mVac (into 2 kΩ min) or open collector (1 A at 100 V max), with a maximum frequency of 2500 Hz.

Sensor and Installation Options

Transducers are sold separately from the monitor unit. The series supports multiple installation configurations:

  • Clamp-On Transducers: Available in standard sizes for pipes 25 mm to 3 m (1" to 120") and small-pipe sets for 6 to 25 mm (¼" to 1"). High-temperature versions are available for process temperatures up to 200°C.
  • Insertion Probes: Available in lengths from 8" to 48", featuring a NEMA 6 (IP67) rating. Wetted materials include 316 SS, Ultem®, FKM, and nylon.
  • Cable Lengths: Standard cable length is 6 m (20'). Options for 50' or 100' cables are available via model suffixes; armored conduit options require consultation with Engineering.

Display and Configuration

The monitor features a 2-line backlit LCD display showing rate and totalizer values. Units can be configured for various engineering units including feet, gallons, liters, cubic meters, acre-feet, oil barrels (42 gallon), liquor barrels (32.5 gallons), lb, and kg.

Key Product Differences

The FD-400 Series is differentiated by output configuration and power supply options:

  • FD-400: Basic rate and totalizer with no analog or relay outputs.
  • FD-41x Models (e.g., FD-410, FD-411): Include one or two 4-20 mA outputs; some models combine 4-20 mA with pulse or relay outputs.
  • FD-42x Models (e.g., FD-420, FD-422): Feature dual or quad relay configurations for alarm and control applications.
  • FD-43x Models (e.g., FD-430, FD-433): Provide rate pulse outputs in single or double channel configurations.

Power supply variations are indicated by suffixes such as "-230VAC" for 230 Vac units and "-24VDC" for 24 Vdc units. Transducer model numbers distinguish between standard clamp-on (FD-400C), small-pipe clamp-on, high-temp versions (-HT), and insertion probes (FD-400I).

Accessories

consumables

COUPLING GREASE FDT-30/FDT-80
TWD3,551 / each
0 In Stock
6 GRM GREASE FOR FD/FDT SERIES
TWD1,389 / each
10 In Stock

sensors

SMALL PIPE CLAMP ON XDUCER SET
TWD81,411 / each
0 In Stock
STD SIZE CLAMP ON XDUCER SET
TWD71,619 / each
0 In Stock
STD SIZE CLAMP ON XDUCER SET
TWD65,699 / each
0 In Stock
STD SIZE CLAMP ON XDUCER SET
TWD60,567 / each
0 In Stock
en-TW
en_TW
Save Configuration