Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
OM-CP-BRIDGE101A-Series
Compact USB Bridge/Strain Gage Data Logger with Large Storage
Models In Stock
- Multiple Start/Stop Function
- Ultra High Speed Download
- 1 Million Reading Storage Capacity
- Memory Wrap
OM-CP-BRIDGE101A-Series
From
TWD
26,664
Models In Stock
Product Overview
- Approvals CE
- Battery life 10 mo
- Battery Size and Type 3.6V Li-ion
- Baud Rate 115200
- Calibration Accuracy Strain : ±0.01%
- Data Interface USB
- Data protection Access by password
- Height 64 mm
- Humidity Range 0 to 90% RH non-condensing
- Input Control Signal 0 to 2.5 V
- LED Indicators Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition
- Length 36 mm
- Materials ABS
- Measurement Type Strain
- Memory 1,000,000 Readings
- Memory Modes Yes
- Memory Note 1,000,000 readings; software configurable memory wrap 333,000 readings in multiple start/stop mode
- Multi Start/Stop Mode Note To Start the Device: Press and hold the pushbutton for five seconds, the green LED will flash during this time. The device has started logging, To Stop the Device: Press and hold the pushbutton for five seconds, the red LED will flash during this time. The device has stopped logging, Real Time Recording: The device may be used with PC to monitor and record data in real-time
- Number of Measurements 1
- Operating Temperature, Max 80 °C
- Operating Temperature, Min -40 °C
- Measurement Pressure, Max 0 psi
- Measurement Pressure Type N/A
- Process Connection Size N/A
- Process Connection Type N/A
- Real Time Recording The device may be used with PC to monitor and record data in real-time
- Sampling Rate 4 Hz (4 updates/second)
- Sampling Rate Note 4 Hz to 1 every 24 hours
- Series ID OM-CP-BRIDGE101A-Series
- Software Windows XP SP3 / Vista / 7 and 8 (32 and 64 - bit)
- Start Modes Delayed Start, Immediate Start
- Stop Modes Manual Through Software
- Supply Power Type Battery
- Time Accuracy ±1 minute/month
- Weight 24 g
- Width 16 mm
Supported Applications
The Omega OM-CP-BRIDGE101A is a battery-powered, stand-alone data logger designed to measure and record voltage signals from strain gages, load cells, and other low-level DC sources. The series supports monitoring of stress, torque, strain, pressure, and data acquisition from various sensors and transducers.
Operating Conditions & Performance
The OM-CP-BRIDGE101A operates in ambient temperatures ranging from -40 to 80°C (-40 to 176°F) with a humidity rating of 0 to 90% RH non-condensing. The device features an IP65 enclosure rating and is constructed from ABS plastic, weighing 24 g (0.8 oz). Data logging rates are configurable from 4 Hz down to one reading every 24 hours.
Performance specifications vary by input range:
- ±30 mV Range: Resolution of 1 μV; Calibrated Accuracy ±0.01% FSR; ±3 microvolts
- ±150 mV Range: Measurement Range ±160 mV; Resolution 5 μV; Calibrated Accuracy ±0.01% FSR; ±16 microvolts
- ±1000 mV Range: Measurement Range ±1200 mV; Resolution 50 μV; Calibrated Accuracy ±0.01% FSR; ±120 microvolts
All ranges utilize a reference voltage of 2.5V and an input range of 0 to 2.5V. Time accuracy is specified as ±1 minute/month at 20°C (68°F) for stand-alone data logging.
Power & Storage
The unit is powered by a user-replaceable 3.6V lithium battery included with the device. Typical battery life is 10 months at a 1-minute rate with a 350Ωohm load, or 2 years at a 1-minute rate with a 1000 ohm load. The logger stores up to 1,000,000 readings in non-volatile solid-state memory and supports software-configurable memory wrap of 333,000 readings in multiple start/stop mode.
Configuration Options
The series offers configurable input ranges (±30 mV, ±150 mV, or ±1000 mV) and optional NIST calibration certificates. Start modes include immediate start, delay start up to 24 months, and multiple pushbutton start/stop functionality.
Enclosure & Environmental Options
An optional weatherproof enclosure is available for harsher environments:
- OM-CP-WATERBOX101A: Weatherproof NEMA 4 (IP65) enclosure constructed from anodized aluminum with a polycarbonate cover. Dimensions are 62 H x 93 W x 25 mm D (2.45 x 3.66 x 0.93"); weight is 140 g (5 oz). Operating temperature for this enclosure configuration is -20 to 80°C (-4 to 176°F).
- OM-CP-WATERBOX101A-KIT: Maintenance kit for the OM-CP-WATERBOX101A.
Data Retrieval & Software
Data retrieval is performed via a USB connection to a PC (interface cable required) at 115,200 baud. The series requires Windows software for operation:
- OM-CP-IFC200: Includes Windows software and a 1.8 m (6') USB interface cable.
Key Product Differences
The series is distinguished by input range selection and certification options:
- OM-CP-BRIDGE101A-30MV / -CERT: Bridge/strain gage data logger with ±30 mV range; the CERT variant includes a NIST calibration certificate.
- OM-CP-BRIDGE101A-150MV / -CERT: Bridge/strain gage data logger with ±150 mV range; the CERT variant includes a NIST calibration certificate.
- OM-CP-BRIDGE101A-1000MV / -CERT: Bridge/strain gage data logger with ±1000 mV range; the CERT variant includes a NIST calibration certificate.
Status indicators include Green and Red LEDs to denote logging rates, delay start mode, low battery/full memory conditions, or alarm states. A replacement 3.6V lithium battery (OM-CP-BAT105) is available as an accessory.
PDFs & Manuals