Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
Adjustable-Switches
Adjustable Current Switch
- Overload Conditions
- Underload Conditions
- Normal Operating Conditions
- Broken Belts
- Belt Slippage
- Locked Rotors
- Equipment Failure
- Fans
- Pumps
- Compressors
- Motors
- Ovens
- Industrial Equipment
- Lighting Status and Usage
- Electrical Load Status
- Local Alarms (Strobes and Audible Alarms)
- Preventative Maintenance Scheduling
Adjustable-Switches
From
TWD
5,749
Product Overview
- Applications Air and HVAC, Building and Maintenance, Control Panel, Environmental Monitoring, Flow Measurement, Heating Equipment, Industrial and Manufacturing
- Electrical Connection Screw Terminal
- Enclosure Material ABS, Polycarbonate
- Enclosure Ratings UL94 V-0
- Frequency 40 to 1 kHz
- Hysteresis 10% of trip point, typical
- Isolation 2200 Vac
- LED Indicators Red
- Materials ABS
- Measurement Type AC Current
- Operating Temperature, Max 104 °F
- Operating Temperature, Min 5 °F
- Relative Humidity 0 to 95%, Non-Condensing
- Response Time See Chart
- Series ID Adjustable-Switches
- Setpoint Type Adjustable
- Supply Power Type Induction
- Supply Voltage Induced from the Monitored Conductor
- Switch Rating 0.2 A @ 200 Vac/Vdc
- Tightening Torque 4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm)
- Wire Gauge 22 to 16 AWG
Supported Applications
The ACI Adjustable Current Switch series (models A/ACS2, A/ACSX2, A/ASCS2, A/ASCS2-L, and A/ASCSX2) is designed for AC current monitoring applications. These switches detect equipment failure, support preventative maintenance, monitor status, and track electrical load conditions. Documented use cases include identifying overload or underload conditions, broken belts, locked rotors, fans, pumps, compressors, motors, ovens, industrial equipment, lighting status, local alarms, and determining equipment run time for load trending.
The series supports logging contact closures to building management systems or PLCs. Solid-core versions are suitable for new installations or OEM applications, while split-core versions facilitate retrofit applications or service technician use on insulated conductors only.
Operating Conditions & Performance
The switches monitor AC Current with a maximum voltage of 600 VAC and an operating frequency range of 40 to 1 kHz. Sensor power is induced from the monitored conductor, eliminating external excitation requirements. The isolation voltage rating is 2200 VAC.
- Operating Temperature: 5 to 104°F (-15 to 40°C)
- Humidity Range: 0 to 95%, non-condensing
- Hysteresis: Typically 10% of the trip point
- Contact Resistance: < 10 Ohms (tripped) | > 1 Meg Ohm (Open)
- Status Contact Rating: 0.2A @ 200 VAC/VDC
Response time varies by model and current level, ranging from values such as 60 mS for the A/ASCS2-L at 20 Amps to 400 mS for the same model at 0.60 Amps. Specific response times are documented in a table on page 2 of the data sheet.
Configuration Options
The series offers configurable options across core style, contact type, and measurement ranges to address specific installation needs:
- Core Style: Available in Solid-Core (A/ACS2, A/ACSX2) or Split-Core versions (A/ASCS2, A/ASCSX2, A/ASCS2-L). The aperture size is 0.75" (19.05 mm).
- Contact Type: Normally-Open "N/O" or Normally-Closed "N/C" configurations.
- Ampereage Ranges: Models support ranges including 0 to 250A, with adjustable trip points such as 0.5 to 220A (Solid-Core), 1.5 to 220A (Split-Core A/ASCS2/A/ASCSX2), and 0.6 to 180A (A/ASCS2-L).
- Mounting: Features a patented 35 mm Din Rail mounting foot (U.S. Patent No. 7,416,421). Minimum mounting distance is 1" (2.6 cm) between the current switch and relays, contactors, or transformers.
- Housing Material: PC/ABS (Polycarbonate/ABS Blend) with a UL94-V0 flammability rating.
Electrical connections utilize a 2 Position Screw Terminal Block that is not polarity sensitive. The terminal block accepts 16 to 22 AWG copper wires only, with a torque rating of 4.43 to 5.31 in-lbs (0.5 to 0.6 Nm). Visual status indication includes a Red LED when monitored current is above the trip point and a Blue LED when below.
Key Product Differences
The series distinguishes models by core construction, contact logic, and specific ampereage ranges:
- A/ACS2 (Item # 142355): Solid-Core with Normally-Open contacts; Amp Range 0 to 250A; Trip Point 0.5 to 220A.
- A/ACSX2 (Item # 142354): Solid-Core with Normally-Closed contacts; Amp Range 0 to 250A; Trip Point 0.5 to 220A.
- A/ASCS2 (Item # 142353): Split-Core with Normally-Open contacts; Amp Range 0 to 250A; Trip Point 1.5 to 220A.
- A/ASCSX2 (Item # 142370): Split-Core with Normally-Closed contacts; Amp Range 0 to 250A; Trip Point 1.5 to 220A.
- A/ASCS2-L (Item # 142352): Split-Core with Normally-Open contacts; Amp Range 0 to 250A; Trip Point 0.6 to 180A.
All models carry UL/CUL US Listed (UL 508) Ind. Control Equipment approval (File # E309723), CE, RoHS2, WEEE, and UKCA certifications. The product is not intended for Life or Safety applications nor for use in hazardous or classified locations.