4-Channel 7 Thermocouple Types Datalogger USB output
- Seven thermocouple types: K,J,T,E,R,S,N
- Datalogging capacity 16,800 records
- Higher accuracy
- Relative (REL) and differential measurement
Product Overview
- Additional Features 1 Max /Min /AVG /Time and data hold functions
- Data Interface USB
- Display Type LCD
- Display Type Note 4-channel and 4-digit LCD display with backlight
- Measurement Type Temperature
- Number of Measurements 4
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Samples,Max 16800
- Series ID HH1384-Series
- Software Compatibility Compatable with Windows XP /7~10
- Storage Humidity, Max <80% RH
- Storage Humidity, Min 0
- Storage Temperature, Max 50 °C
- Storage Temperature, Min 0 °C
- Storage Temperature Note 0°C to 50°C, relative humidity under 80%
- Temperature Accuracy ± 0.05% rdg + 3 °C
- Temperature Accuracy Note K/J/E/T/N type: ± (0.05% rdg + 0.7°C/1°F) R/S Type: ± (0.05% rdg + 3°C/5.4°F) Below -100°C(-148°F) K,J,T,E: +0.15% reading N: +0.45% reading
- Temperature Measurement, Max 1767 °C
- Temperature Measurement, Min 0 °C
- Temperature Measurement Note ITS-90
- Temperature Resolution ± 0.1 °C
- Temperature Resolution Note 0.1: K / J / T / E / N / R / S ≤ 1000°C 1: R / S and K / J / E / N ≥ 1000°C
- Temperature Sensor Type Thermocouple
Supported Applications
The HH1385 is a digital 4-input thermometer and data logger that works with any K, J, E, T, R, S or N type thermocouple sensor. It delivers higher accuracy and better uniformity across thermocouple types, and stores over 16,800 temperature readings, making it a practical tool for multi-point temperature surveys, equipment commissioning and long-term process monitoring.
Up to four thermocouples plug directly into miniature female thermocouple receptacles, and logged data transfers to a PC over a USB serial interface for analysis and record-keeping.
Operating Conditions & Performance
The logger operates on the ITS-90 temperature scale. For K/J/E/T/N types, accuracy is ±(0.05% rdg + 0.7°C); for R/S type it is ±(0.05% rdg + 3°C). Below -100°C (-148°F), accuracy is ±0.15% reading for K, J, T and E and ±0.45% reading for N. The temperature coefficient is 0.05% of reading ±0.07°C per °C outside the specified 18 to 28°C band.
Display resolution is 0.1 for K/J/T/E/N/R/S at or below 1000°C and 1 for R/S and K/J/E/N at or above 1000°C. The instrument operates from 0°C to 50°C (32°F to +122°F) at less than 80% RH, with storage over the same 0°C to 50°C range under 80% relative humidity.
Configuration Options
Although the HH1385 is a single instrument, its capability lies in how far each supported thermocouple type can reach. The type selected sets the usable span:
- Type K: -200°C to +1372°C (-328°F to +2501°F)
- Type J: -210°C to +1200°C (-346°F to +2192°F)
- Type T: -250°C to +400°C (-418°F to +752°F)
- Type E: -210°C to +1000°C (-346°F to +1832°F)
- Type N: -150°C to +1300°C (-238°F to +2372°F)
- Type R/S: -0°C to +1767°C
Key Product Differences
The series comprises a single model, the HH1385, a 4-channel USB-output datalogger supporting seven thermocouple types (K, J, E, T, R, S, N) with over 16,800 stored readings.